Heat and mass transfer in liquid desiccant air-conditioning process at low flow conditions

被引:19
|
作者
Peng, S. W. [1 ]
Pan, Z. M. [2 ]
机构
[1] Thermal Res & Applicat Ltd, Edmonton, AB T6R 0H6, Canada
[2] Wuhan ES Power Technol Ltd, Wuhan 430074, Peoples R China
关键词
Liquid desiccant; Air-conditioning; HVAC; Non-equilibrium heat and mass transfer; DEHUMIDIFICATION; SYSTEM;
D O I
10.1016/j.cnsns.2009.01.009
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
This paper investigates the transient heat and mass transfer in liquid desiccant air-conditioning process at low flow conditions. Using local volumetric average approach, one-dimensional non-equilibrium heat and mass transfer models are developed to describe the humid air and liquid desiccant interaction at counter flow configuration. Using triethylene glycol solution as desiccant, some experimental studies are completed. Experimental results are used to justify the numerical models. Numerical results are then obtained to demonstrate process characteristics. The models include a transient desiccant flow model for initial liquid desiccant building-up process, empirical wetted specific surface ratio for mass transfer, and heat and mass transfer coefficients. The objective of this research is to develop a process analytical tool for liquid desiccant air-conditioner design. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3599 / 3607
页数:9
相关论文
共 50 条
  • [1] Comparison of Modelled and Measured Heat and Mass Transfer in a Liquid Desiccant Air-Conditioning System
    Mandow, Wael
    Muetzel, Martin
    Fleig, Daniel
    Lowenstein, Andrew
    Jordan, Ulrike
    PROCEEDINGS OF THE ISES EUROSUN 2018 CONFERENCE - 12TH INTERNATIONAL CONFERENCE ON SOLAR ENERGY FOR BUILDINGS AND INDUSTRY, 2018, : 648 - 658
  • [2] Experimental assessment of mass transfer characteristics of polypropylene surfaces for low flow falling film liquid desiccant air-conditioning applications
    Khan, Rehan
    Kumar, Ritunesh
    Ma, Zhenjun
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2021, 169
  • [3] Mass Transfer Correlation for Tubular Membrane-Based Liquid Desiccant Air-Conditioning System
    Cihan, Ertugrul
    Kavasogullari, Baris
    Demir, Hasan
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (02) : 519 - 529
  • [4] Mass Transfer Correlation for Tubular Membrane-Based Liquid Desiccant Air-Conditioning System
    Ertuğrul Cihan
    Barış Kavasoğulları
    Hasan Demir
    Arabian Journal for Science and Engineering, 2020, 45 : 519 - 529
  • [5] Membrane distillation regeneration of liquid desiccant solution for air-conditioning: Insights into polarisation effects and mass transfer
    Hung Cong Duong
    Ansari, Ashley Joy
    Hai Thuong Cao
    Nguyen Cong Nguyen
    Khac-Uan Do
    Long Duc Nghiem
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2020, 19
  • [6] Application Research on Waste Heat Driven Liquid Desiccant Air-conditioning System
    Zhang Liang
    Liu Jianhua
    Zhang Haijiang
    Ge Qilin
    Zhu Liwei
    Zhang Huichen
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [7] Experimental Research on Liquid Desiccant Air-conditioning Unit
    Feng, Yueyan
    Li, Yinglin
    2016 3RD INTERNATIONAL CONFERENCE ON MANUFACTURING AND INDUSTRIAL TECHNOLOGIES, 2016, 70
  • [8] Control strategies for a liquid desiccant air-conditioning system
    Ge, Gaoming
    Xiao, Fu
    Niu, Xiaofeng
    ENERGY AND BUILDINGS, 2011, 43 (06) : 1499 - 1507
  • [9] PERFORMANCE OPTIMIZATION OF LIQUID DESICCANT AIR-CONDITIONING PROCESSES
    Jiang, J. J.
    Liu, X. H.
    Zhang, T.
    Zhang, L.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 745 - 750
  • [10] The desiccant air-conditioning system
    Riffat, S.B., 1600, Ambient Press Ltd (25):