A 2.45 GHz intense proton source and low energy beam transport system for China Initiative Accelerator Driven Sub-Critical reactor system

被引:18
|
作者
Wu, Q. [1 ]
Zhang, Z. M. [1 ]
Sun, L. T. [1 ]
Yang, Y. [1 ,2 ]
Ma, H. Y. [1 ]
Cao, Y. [1 ]
Zhang, X. Z. [1 ]
Zhao, H. W. [1 ]
机构
[1] Chinese Acad Sci, IMP, Lanzhou 730000, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100039, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 02期
基金
中国国家自然科学基金;
关键词
D O I
10.1063/1.4824804
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At Institute of Modern Physics, a cw 35 keV, 20 mA intense proton source and the low energy beam transport system (LEBT) have been developed for China Initiative Accelerator Driven Sub-Critical reactor system. In order to ensure high quality transmission of the intense ion beam from the exit of ion source to Radio Frequency Quadrupole (RFQ), a low energy beam transport line is used to focus beam to the RFQ entrance and match the Twiss parameters to the RFQ requirements. The 35 keV, 20 mA ion beam extracted by a three-electrode extraction system from the ion source passes through the LEBT to the RFQ entrance and the root-mean-square emittance is measured to be less than 0.2 pi mm mrad. The commissioning results of the ion source and low energy beam transport system are described in this paper. The beam quality and transmission efficiency are also studied. (c) 2013 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Status of intense permanent magnet proton source for China-accelerator driven sub-critical system Linac
    Wu, Q.
    Ma, H. Y.
    Yang, Y.
    Sun, L. T.
    Zhang, X. Z.
    Zhang, Z. M.
    Zhao, H. Y.
    He, Y.
    Zhao, H. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [2] Accelerator-driven sub-critical reactor system (ADS) for nuclear energy generation
    SS Kapoor
    Pramana, 2002, 59 : 941 - 950
  • [3] Accelerator-driven sub-critical reactor system (ADS) for nuclear energy generation
    Kapoor, SS
    PRAMANA-JOURNAL OF PHYSICS, 2002, 59 (06): : 941 - 950
  • [4] Overtemperature protection systems for spallation target in China initiative accelerator driven sub-critical system
    Cui, Wenjuan
    He, Zhiyong
    Ma, Wenjing
    Yin, Kai
    Zhao, Qiang
    Zhang, Xueying
    Chen, Zhiqiang
    ANNALS OF NUCLEAR ENERGY, 2019, 128 : 358 - 365
  • [5] The electron accelerator driven sub-critical system
    Liu, Bin
    Zhang, Xinying
    Liu, Fang
    Dou, Wenqiang
    Wang, Jibing
    NUCLEAR ENGINEERING AND DESIGN, 2022, 386
  • [6] Study on Power Control Methodology of the Accelerator Driven Sub-critical Reactor System
    Yang, YuXin
    Zhou, Zhiwei
    He, Ting
    Wu, Zhenlong
    Li, Donghai
    2017 17TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2017, : 809 - 814
  • [7] Magnetic measurement of conventional magnet for china accelerator driven sub-critical system
    Institute of High Energy Physics, Chinese Academy of Sciences, Beijing
    100049, China
    Yuanzineng Kexue Jishu, (487-491):
  • [8] Fuel array project for the sub-critical reactor of accelerator driven system verification facility
    School of Nuclear Science and Technology, Nanhua University, Hengyang 421001, China
    不详
    Hedongli Gongcheng, 2006, 4 (5-7):
  • [9] ELECTRONICS FOR INSTRUMENTATION AND CONTROLS IN ACCELERATOR DRIVEN SUB-CRITICAL SYSTEM
    Cui, Wenjuan
    He, Zhiyong
    Zhao, Qiang
    He, Yichuan
    Luo, Yuxi
    PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2016, VOL 1, 2016,
  • [10] Preliminary conceptual design of accelerator driven sub-critical system
    Li, Xun-Zhao
    Wu, Hong-Chun
    Cao, Liang-Zhi
    Zheng, You-Qi
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2013, 47 (SUPPL1): : 224 - 228