Comparing isolated-check visual evoked potential, pattern visual evoked potential, and standard automated perimetry in dysthyroid optic neuropathy eyes

被引:9
|
作者
Qi, Xin [1 ]
Tong, Boding [1 ]
Hu, Weikun [2 ]
Luo, Ban [2 ]
机构
[1] Cent South Univ, Dept Ophthalmol, Xiangya Hosp 2, Changsha 410011, Hunan, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Hosp, Dept Ophthalmol, Tongji Med Coll, Wuhan 430030, Hubei, Peoples R China
关键词
OCULAR HYPERTENSION; GRAVES ORBITOPATHY; DIAGNOSIS; ABILITY;
D O I
10.1038/s41433-020-01274-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective To determine the diagnostic ability of isolated-check visual evoked potential (icVEP), pattern visual evoked potential (pVEP), and standard automated perimetry (SAP) between dysthyroid optic neuropathy (DON) and thyroid-associated ophthalmopathy (TAO) without DON (non-DON). Methods This is a case-control study, 49 bilateral patients (26 DON and 23 non-DON) were included. icVEP, pVEP, and SAP were conducted in all the subjects, icVEP parameters compared were signal-to-noise ratios (SNRs) under 8, 16, and 32% depth of modulation (DOM). pVEP parameters compared were amplitude and latency. SAP parameters were mean deviation (MD) and pattern standard deviation (PSD). The area under the receiver operating characteristic (ROC) curve (AUC), net reclassification index (NRI), integrated discrimination index (IDI), and decision curve analysis (DCA) were applied for analysis. Results In icVEP, values of SNR in DON were significantly smaller than non-DON (p < 0.05). In pVEP, P100 latent time in DON was significantly larger than non-DON (p = 0.0026). In SAP, value of PSD in DON was larger than non-DON (p = 0.0006), and value of MD in DON was smaller (p = 0.0007). AUC, NRI, and IDI among the three tests were not significantly different. DCA showed that SNR of icVEP under 8% DOM was the farthest from the two extreme curves. Conclusions icVEP, pVEP, and SAP have equal diagnostic capabilities to discern between DON and non-DON. In addition, icVEP may represent a significant ancillary diagnostic approach to DON detection, with more clinical benefit.
引用
收藏
页码:2556 / 2563
页数:8
相关论文
共 50 条
  • [1] Comparing isolated-check visual evoked potential, pattern visual evoked potential, and standard automated perimetry in dysthyroid optic neuropathy eyes
    Xin Qi
    Boding Tong
    Weikun Hu
    Ban Luo
    Eye, 2021, 35 : 2556 - 2563
  • [2] Utility of isolated-check visual evoked potential technique in dysthyroid optic neuropathy
    Ban Luo
    Rong Liu
    Shanluxi Wang
    Weikun Hu
    Yunping Li
    Boding Tong
    Hong Zhang
    Xin Qi
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 2031 - 2040
  • [3] Utility of isolated-check visual evoked potential technique in dysthyroid optic neuropathy
    Luo, Ban
    Liu, Rong
    Wang, Shanluxi
    Hu, Weikun
    Li, Yunping
    Tong, Boding
    Zhang, Hong
    Qi, Xin
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (07) : 2031 - 2040
  • [4] Correction to: Utility of isolated‑check visual evoked potential technique in dysthyroid optic neuropathy
    Ban Luo
    Rong Liu
    Shanluxi Wang
    Weikun Hu
    Yunping Li
    Boding Tong
    Hong Zhang
    Xin Qi
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 2725 - 2725
  • [5] Utility of isolated-check visual evoked potential technique in dysthyroid optic neuropathy (10.1007/s00417-02305975- 9 2023)
    Luo, Ban
    Liu, Rong
    Wang, Shanluxi
    Hu, Weikun
    Li, Yunping
    Tong, Boding
    Zhang, Hong
    Qi, Xin
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (09) : 2725 - 2725
  • [6] Comparison of isolated-check visual evoked potential and standard automated perimetry in early glaucoma and high-risk ocular hypertension
    Chen, Xiang-Wu
    Zhao, Ying-Xi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (04) : 599 - 604
  • [7] Comparison of isolated-check visual evoked potential and standard automated perimetry in early glaucoma and high-risk ocular hypertension
    Xiang-Wu Chen
    Ying-Xi Zhao
    International Journal of Ophthalmology, 2017, (04) : 599 - 604
  • [8] Isolated-check visual evoked potential: a more sensitive tool to detect traumatic optic neuropathy after orbital fracture
    Yanjie Tian
    Yinhao Wang
    Ziyuan Liu
    Xuemin Li
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 547 - 555
  • [9] Isolated-check visual evoked potential: a more sensitive tool to detect traumatic optic neuropathy after orbital fracture
    Tian, Yanjie
    Wang, Yinhao
    Liu, Ziyuan
    Li, Xuemin
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (02) : 547 - 555
  • [10] Correlation of the multifocal visual evoked potential and standard automated perimetry in compressive optic neuropathies
    Danesh-Meyer, HV
    Carroll, SC
    Gaskin, BJ
    Gao, A
    Gamble, GD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (04) : 1458 - 1463