Diurnal fluctuation of higher order ocular aberrations: Correlation with intraocular pressure and corneal thickness

被引:0
|
作者
Mierdel, P
Krinke, HE
Pollack, K
Spoerl, E
机构
[1] Dresden Univ Technol, Dept Med Phys & Biomed Engn, D-01307 Dresden, Germany
[2] Dresden Univ Technol, Eye Clin, D-01307 Dresden, Germany
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: Optimal wavefront-guided refractive corneal laser surgery requires sufficiently exact data of optical higher order aberrations. We investigated whether these aberrations had a systematic during-the-day variation, studied the range of variation, and changes in intraocular pressure and central corneal thickness. METHODS: In 22 eyes of 22 young volunteers the optical aberrations of higher order were measured by means of a Tscherning-type ocular aberrometer three times during one day (7 AM, 12 noon, 4 PM). In addition, in 12 of these eyes the intraocular pressure and central corneal thickness were measured. The intraocular wavefront aberration was computed using Zernike polynomials up to the sixth order, and Zernike coefficients of third and fourth order were analyzed. RESULTS: Only the coefficient Z(4)(2) (C13) showed a significant increase during the day by a mean 0.016 mum. A significant regression could be detected between changes of coefficients Z(3)(3), Z(4)(-2) Z(4)(0), Z(4)(4) and changes of intraocular pressure or central corneal thickness during the day. CONCLUSIONS: Due to the small values, the measured during-the-day changes of higher order aberrations had no direct practical consequences for the aberrometry-guided corneal laser surgery. Alterations of some Zernike coefficients during the day may be explained by the biomechanical behavior of the cornea.
引用
收藏
页码:236 / 242
页数:7
相关论文
共 50 条
  • [1] Diurnal fluctuation of higher order ocular aberrations: Correlation with Intraocular pressure and corneal thickness
    Cheng, ACK
    Lam, DSC
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (02) : 201 - 201
  • [2] Diurnal Variation of Ocular Hysteresis, Corneal Thickness, and Intraocular Pressure
    Shen, Meixiao
    Wang, Jianhua
    Qu, Jia
    Xu, Suzhong
    Wang, Xiaoxing
    Fang, Haizhen
    Lu, Fan
    [J]. OPTOMETRY AND VISION SCIENCE, 2008, 85 (12) : 1185 - 1192
  • [3] Corneal Thickness Association With Ocular and Corneal High-Order Aberrations
    Mohamed, Engy M.
    Woitowicz, Jadwiga C.
    Bowman, Wayne
    Cavanagh, H. Dwight
    Mootha, Vinod
    Verity, Steven
    McCulley, James P.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (06): : 297 - 301
  • [4] Diurnal variations in intraocular pressure and central corneal thickness and the correlation between these factors in dogs
    Garzon-Ariza, Alicia
    Guisado, Alicia
    Galan, Alba
    Martin-Suarez, Eva
    [J]. VETERINARY OPHTHALMOLOGY, 2018, 21 (05) : 464 - 470
  • [5] Effect of trabeculectomy on ocular and corneal higher order aberrations
    Fukuoka, Shima
    Amano, Shiro
    Honda, Norihiko
    Mimura, Tatsuya
    Usui, Tomohiko
    Araie, Makoto
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (05) : 460 - 466
  • [6] Effect of trabeculectomy on ocular and corneal higher order aberrations
    Shima Fukuoka
    Shiro Amano
    Norihiko Honda
    Tatsuya Mimura
    Tomohiko Usui
    Makoto Araie
    [J]. Japanese Journal of Ophthalmology, 2011, 55 : 460 - 466
  • [7] Central corneal thickness and intraocular pressure in ocular hypertension
    Consuelo Gutierrez
    Jose R. V. Casaponsa
    Francisco Munoz
    Gema Rebolleda
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 463 - 463
  • [8] Central corneal thickness and intraocular pressure in ocular hypertension
    Gutierrez, C
    Casaponsa, JRV
    Munoz, F
    Rebolleda, G
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (06) : 463 - 463
  • [9] Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties
    Villas-Boas, Flavia Silva
    Doi, Larissa Morimoto
    Siqueira Sousa, Aline Katia
    Melo, Luiz Alberto S., Jr.
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (03) : 296 - 301
  • [10] Diurnal Fluctuation of Intraocular Pressure
    Kaufman, Paul L.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (14) : 6427 - 6427