Automated Window-Level Setting Adjustment for Virtual Monoenergetic Images in Dual Energy CT with Iodine Contrast

被引:0
|
作者
Liu, J. [1 ]
Zhang, Y. [2 ]
Chen, L. [1 ]
Lin, T. [1 ]
Price, R. [1 ]
Fan, J. [3 ]
Ma, C. [1 ]
机构
[1] Fox Chase Canc Ctr, 7701 Burholme Ave, Philadelphia, PA 19111 USA
[2] Air Force Mil Med Univ, Tangdu Hosp, Xian, Shaanxi, Peoples R China
[3] Univ S Alabama, Mobile, AL USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-H300-Ge
引用
收藏
页码:E166 / E166
页数:1
相关论文
共 50 条
  • [1] Material-of-Interest Rased Window-Level Settings for Unenhanced Virtual Monoenergetic Images in Dual Energy CT
    Liu, J.
    Ma, C.
    Zhang, Y.
    Lin, T.
    Price, R.
    Fan, J.
    Chen, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E622 - E622
  • [2] Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography
    Meier, A.
    Wurnig, M.
    Desbiolles, L.
    Leschka, S.
    Frauenfelder, T.
    Alkadhi, H.
    CLINICAL RADIOLOGY, 2015, 70 (11) : 1244 - 1251
  • [3] Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
    Liang, Hongwei
    Zhou, Yang
    Zheng, Qiao
    Yan, Gaowu
    Liao, Hongfan
    Du, Silin
    Zhang, Xiaohui
    Lv, Fajin
    Zhang, Zhiwei
    Li, Yong-mei
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [4] Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
    Hongwei Liang
    Yang Zhou
    Qiao Zheng
    Gaowu Yan
    Hongfan Liao
    Silin Du
    Xiaohui Zhang
    Fajin Lv
    Zhiwei Zhang
    Yong-mei Li
    Insights into Imaging, 13
  • [5] Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
    Booij, Ronald
    van der Werf, Niels R.
    Dijkshoorn, Marcel L.
    van der Lugt, Aad
    van Straten, Marcel
    DIAGNOSTICS, 2022, 12 (06)
  • [6] Determining the Optimal Energy Level of Virtual Monoenergetic Images in Dual-Source CT for Diagnosis of Bowel Obstruction and Colitis
    Lahuna, Loris
    Greffier, Joel
    Goupil, Jean
    Frandon, Julien
    Pastor, Maxime
    De Oliveira, Fabien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTICS, 2023, 13 (23)
  • [7] Optimizing window settings for improved presentation of virtual monoenergetic images in dual-energy computed tomography
    Fu, Wanyi
    Marin, Daniele
    Ramirez-Giraldo, Juan Carlos
    Choudhury, Kingshuk Roy
    Solomon, Justin
    Schabel, Christoph
    Patel, Bhavik N.
    Samei, Ehsan
    MEDICAL PHYSICS, 2017, 44 (11) : 5686 - 5696
  • [8] Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT
    Leng, Shuai
    Yu, Lifeng
    Fletcher, Joel G.
    McCollough, Cynthia H.
    RADIOLOGY, 2015, 276 (02) : 562 - 570
  • [9] Influence of beam hardening in dual-energy CT imaging: phantom study for iodine mapping, virtual monoenergetic imaging, and virtual non-contrast imaging
    Risa Kanatani
    Takashi Shirasaka
    Tsukasa Kojima
    Toyoyuki Kato
    Masateru Kawakubo
    European Radiology Experimental, 5
  • [10] Influence of beam hardening in dual-energy CT imaging: phantom study for iodine mapping, virtual monoenergetic imaging, and virtual non-contrast imaging
    Kanatani, Risa
    Shirasaka, Takashi
    Kojima, Tsukasa
    Kato, Toyoyuki
    Kawakubo, Masateru
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)