Cardiac implantable device outcomes and lead survival in adult congenital heart disease

被引:7
|
作者
Bowman, Hilary C. [1 ]
Shannon, Kevin M. [2 ]
Biniwale, Reshma [3 ]
Moore, Jeremy P. [2 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[2] Ahmanson UCLA Adult Congenital Heart Dis Ctr, Los Angeles, CA USA
[3] Univ Calif Los Angeles, Dept Cardiothorac Surg, Los Angeles, CA USA
关键词
Adult congenital heart disease; Pacemaker; Defibrillator; Cardiac resynchronization therapy; RESYNCHRONIZATION THERAPY; PACEMAKER THERAPY; COMPLICATIONS; PREVALENCE; EXPERIENCE;
D O I
10.1016/j.ijcard.2020.09.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Long-term outcomes of cardiac implantable electronic devices (CIEDs) are ill-defined in adult congenital heart disease (ACHD). Objective: To assess outcomes of transvenous (TV) and epicardial (EPI) CIEDs in ACHD. Methods: A retrospective review of CIEDs implanted in patients >18 yrs. followed at the Ahmanson/UCLA ACHD Center was performed. Patients were grouped by implant approach. Primary outcomes included time to CIED dysfunction, lead dysfunction and unplanned CIED reintervention. Results: Over a 27-year period, 283 CIEDs (208 TV, 75 EPI) were implanted in 260 ACHD patients. Dysfunction developed in 77 CIEDs (50 TV, 27 EPI) for which 62 underwent unplanned reintervention (47 TV, 15 EPI). Time to CIED dysfunction and unplanned reintervention did not differ by implant approach; however lead dysfunction was greater for EPI vs TV (HR 2.0, 95% CI 1.2-3.2, p = 0.01). Independent predictors of lead failure included cyanosis (HR 2.6, 95% CI 1.1-6.3; p = 0.03), implant indication other than bradycardia (HR 3.3, 95% CI 1.6-6.5; p < 0.01), right-sided Maze operation (HR 2.5, 95% CI 1.3-5.0; p = 0.01), and unipolar lead design (HR 4.5, 95% CI 1.8-11.5; p < 0.01). Importantly, EPI vs TV approach was not associated with lead dysfunction after adjusting for baseline covariates (HR 0.6, 95% CI 0.6-4.3; p=0.3). Conclusion: Overall CIED system dysfunction and reinterventions are similar, whereas lead dysfunction is greater among EPI than TV devices. Patient and procedural differences, rather than EPI vs TV implant approach alone, appear to drive CIED lead outcomes in the ACHD population. Published by Elsevier B.V.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 50 条
  • [1] Outcomes of Cardiac Transplantation for Adult Congenital Heart Disease
    Irving, C.
    Kirk, R.
    Hasan, A.
    Parry, G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S192 - S193
  • [2] The Effects of Cardiac Implantable Electronic Device Personal Protective Equipment Use in Patients with Pediatric and Adult Congenital Heart Disease
    Kelly A. Kean
    Donna J. Fitzgerald
    Mark D. Ayers
    Adam C. Kean
    Pediatric Cardiology, 2023, 44 : 1721 - 1725
  • [3] The Effects of Cardiac Implantable Electronic Device Personal Protective Equipment Use in Patients with Pediatric and Adult Congenital Heart Disease
    Kean, Kelly A. A.
    Fitzgerald, Donna J. J.
    Ayers, Mark D. D.
    Kean, Adam C. C.
    PEDIATRIC CARDIOLOGY, 2023, 44 (08) : 1721 - 1725
  • [4] Implantable defibrillators: from the adult cardiac to the grown up congenital heart disease patient
    Gatzoulis, K
    Frogoudaki, A
    Brill, S
    Stefanadis, C
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 97 : 117 - 122
  • [5] Successful cardiac transplantation outcomes in patients with adult congenital heart disease
    Menachem, Jonathan N.
    Golbus, Jessica R.
    Molina, Maria
    Mazurek, Jeremy A.
    Hornsby, Nicole
    Atluri, Pavan
    Fuller, Stephanie
    Birati, Edo Y.
    Kim, Yuli Y.
    Goldberg, Lee R.
    Wald, Joyce W.
    HEART, 2017, 103 (18) : 1449 - 1454
  • [6] Device complications in adult congenital heart disease
    Hayward, Robert M.
    Dewland, Thomas A.
    Moyers, Brian
    Vittinghoff, Eric
    Tanel, Ronn E.
    Marcus, Gregory M.
    Tseng, Zian H.
    HEART RHYTHM, 2015, 12 (02) : 338 - 344
  • [7] Cardiac catheter intervention complexity and safety outcomes in adult congenital heart disease
    Brida, Margarita
    Diller, Gerhard Paul
    Nashat, Heba
    Barracano, Rosaria
    Kempny, Aleksander
    Uebing, Anselm
    Rigby, Michael L.
    Gatzoulis, Michael A.
    HEART, 2020, 106 (18) : 1432 - 1437
  • [8] Outcomes of permanent pacemakers and implantable cardioverter-defibrillators in an adult congenital heart disease population
    Chami, Jason
    Moore, Benjamin M.
    Nicholson, Calum
    Cordina, Rachael
    Baker, David
    Celermajer, David S.
    INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE, 2024, 15
  • [9] LONG TERM OUTCOMES IN ADULT PATIENTS WITH CONGENITAL HEART DISEASE AND IMPLANTABLE CARDIOVERTER- DEFIBRILLATORS
    Brouillard, Adam Michael
    Al-Hammadi, Noor
    Hunt, Craig
    Gleva, Marye
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 612 - 612
  • [10] Cardiac transplantation in adult Congenital Heart Disease
    Brown, M.
    Chee, K. W.
    Mckenzie, S. C.
    Platts, D. G.
    Javorsky, G.
    EUROPEAN HEART JOURNAL, 2012, 33 : 266 - 267