Image fusion of integrating fluoroscopy into 3D computed tomography in guidance of left atrial appendage closure

被引:22
|
作者
Mo, Bin-Feng [1 ]
Wan, Yi [1 ]
Alimu, Abudushalamu [1 ]
Sun, Jian [1 ]
Zhang, Peng-Pai [1 ]
Yu, Ying [1 ]
Chen, Mu [1 ]
Li, Wei [1 ]
Wang, Zhi-Quan [1 ]
Wang, Qun-Shan [1 ]
Li, Yi-Gang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Xinhua Hosp, Sch Med, Dept Cardiol, 1665 Kong Jiang Rd, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
imaging fusion; left atrial appendage closure; computed tomography; fluoroscopy; transseptal puncture;
D O I
10.1093/ehjci/jez286
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We evaluated the feasibility of left atrial appendage (LAA) closure guided by the image fusion of integrating fluoroscopy into 3D computed tomography (CT). Methods and results A total of 117 consecutive patients who underwent LAA closure with or without the image fusion were matched (1:2). Each LAA closure step of the Image fusion group was guided by the preprocedure CT and image fusion, especially in the plan of LAA measurement and transseptal puncture. All patients were successfully implanted with a WATCHMAN closure device. Comparing the two groups, the mean number of recapture times and the number of devices per patient of the Image fusion group were significantly lower (0.4 +/- 0.5 vs. 0.7 +/- 0.8, P = 0.031 and 1.0 +/- 0.2 vs. 1.1 +/- 0.3, P = 0.027, respectively). The one-time successful deployment rate by the support of the image fusion was higher than in the control group (66.7% vs. 44.9%, P = 0.026). Each case of the Image fusion group was completely occluded with one transseptal puncture, while five of the Non-image fusion group required redo transseptal punctures. During the 45-day follow-up, both group cases presented occlusion efficiency and no major adverse cardiac events were observed. Conclusion Image fusion technique integrating fluoroscopy into the 3D CT is safe and feasible which can be easily incorporated into the procedural work-flow of percutaneous LAA closure. The fusion image can play an important alternative role in the plan of LAA measurement and transseptal puncture site for improving the LAA closure procedure.
引用
收藏
页码:92 / 101
页数:10
相关论文
共 50 条
  • [1] 3D-Multidetector Computed Tomography and Fluoroscopy Fusion in Left Atrial Appendage Closure
    Carneiro, Herman
    Rashid, Imran
    Dallan, Luis Augusto Palma
    Yoon, Sung-Han
    Knezevich, Juliana
    Wass, Sojin
    Lobo, Tabitha
    Mogalapalli, Akhil
    Reed, Joseph
    Galo, Jason
    Rana, Mohammad
    Filby, Steven
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B156 - B157
  • [2] Novel integrated 3D multidetector computed tomography and fluoroscopy fusion for left atrial appendage occlusion procedures
    Roy, A. K.
    Horvilleur, J.
    Cormier, B.
    Cazalas, M.
    Fernandez, L.
    Patane, M.
    Neylon, A.
    Spaziano, M.
    Sawaya, F. J.
    Arai, T.
    Bouvier, E.
    Hovasse, T.
    Lefevre, T.
    Chevalier, B.
    Garot, P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (02) : 322 - 329
  • [3] Innovative 3D Computed Tomography (CT) Modeling and Image Analyses to Optimize Left Atrial Appendage Closure
    Wiktor, Dominik
    Chen, James
    Hansgen, Adam
    Valle, Javier
    Duy Nguyen
    Carroll, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B217 - B217
  • [4] Novel Integrated 3D Multi-Detector Computed Tomography and Fluoroscopy Fusion for Left Atrial Appendage Occlusion Procedures
    Roy, Andrew
    Horvilleur, Jerome
    Cormier, Bertrand
    Cazalas, Maxime
    Fernandez-Lopez, Leticia
    PatanS, Martina
    Neylon, Antoinette
    Spaziano, Marco
    Sawaya, Fadi
    Bouvier, Erik
    Hovasse, Thomas
    Lefevre, Thierry
    Chevalier, Bernard
    Garot, Philippe
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B255 - B255
  • [5] Efficacy of 3D-multidetector computed tomography and fluoroscopy fusion for percutaneous left atrial appendage occlusion procedures
    Carneiro, Herman A. A.
    Dallan, Luis A. P.
    Yoon, Sung-Han
    Arora, Shilpkumar
    Knezevich, Juliana
    Wass, Sojin
    Lobo, Tabitha
    Arruda, Mauricio
    Rashid, Imran
    Filby, Steven J. J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (10) : 2076 - 2083
  • [6] Computed tomography measurement for left atrial appendage closure
    Asami, Masahiko
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (03) : 440 - 449
  • [7] Computed tomography measurement for left atrial appendage closure
    Masahiko Asami
    Cardiovascular Intervention and Therapeutics, 2022, 37 : 440 - 449
  • [8] Left atrial appendage closure guided by 3D computed tomography printing technology: A case control study
    Conti, Michele
    Marconi, Stefania
    Muscogiuri, Giuseppe
    Guglielmo, Marco
    Baggiano, Andrea
    Italiano, Gianpiero
    Mancini, Maria Elisabetta
    Auricchio, Ferdinando
    Andreini, Daniele
    Rabbat, Mark G.
    Guaricci, Andrea Igoren
    Fassini, Gaetano
    Gasperetti, Alessio
    Costa, Fabrizio
    Tondo, Claudio
    Maltagliati, Anna
    Pepi, Mauro
    Pontone, Gianluca
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (06) : 336 - 339
  • [9] Left atrial appendage closure guided by fusion of 3D computational modelling on real-time fluoroscopy: A multicenter experience
    Garot, Philippe
    Gall, Emmanuel
    Zendjebil, Sandra
    Cepas-Guillen, Pedro
    Iriart, Xavier
    Farah, Bruno
    Skurk, Carsten
    Gautier, Alexandre
    Ho, Cheuk Bong
    Bavo, Alessandra M.
    Vaillant, Regis
    Horvilleur, Jerome
    Freixa, Xavier
    Saw, Jacqueline
    de Backer, Ole
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2025, 418
  • [10] Cardiac Computed Tomography Angiography for Left Atrial Appendage Closure
    Saw, Jacqueline
    Lopes, Joao Pedro
    Reisman, Mark
    McLaughlin, Patrick
    Nicolau, Savvas
    Bezerra, Hiram G.
    CANADIAN JOURNAL OF CARDIOLOGY, 2016, 32 (08) : 1033.e1 - 1033.e9