摘要
Images acquired during free breathing using contrast enhanced ultrasound hepatic perfusion imaging exhibits a periodic motion pattern. It needs to be compensated for if a further accurate quantification of the hepatic perfusion analysis is to be executed. To reduce the impact of respiratory motion, image-based breathing gating algorithm was used to compensate the respiratory motion in contrast enhanced ultrasound. The algorithm contains three steps of which respiratory kinetics extracted, image subsequences determined and image subsequences registered. The basic performance of the algorithm was to extract the respiratory kinetics of the ultrasound hepatic perfusion image sequences accurately. In this paper, we treated the kinetics extracted model as a non-negative matrix factorization (NMF) problem. We extracted the respiratory kinetics of the ultrasound hepatic perfusion image sequences by non-negative matrix factorization (NMF). The technique involves using the NMF objective function to accurately extract respiratory kinetics. It was tested on simulative phantom and used to analyze 6 liver CEUS hepatic perfusion image sequences. The experimental results show the effectiveness of our proposed method in quantitative and qualitative.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Manifold learning for image-based breathing gating in ultrasound and MRI
    Wachinger, Christian
    Yigitsoy, Mehmet
    Rijkhorst, Erik-Jan
    Navab, Nassir
    MEDICAL IMAGE ANALYSIS, 2012, 16 (04) : 806 - 818
  • [2] Manifold Learning for Image-Based Breathing Gating with Application to 4D Ultrasound
    Wachinger, Christian
    Yigitsoy, Mehmet
    Navab, Nassir
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT II,, 2010, 6362 : 26 - 33
  • [3] Manifold Learning for Image-Based Breathing Gating in MRI
    Yigitsoy, Mehmet
    Wachinger, Christian
    Navab, Nassir
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [4] Image-based gating of intravascular ultrasound pullback sequences
    O'Malley, Sean M.
    Granada, Juan F.
    Carlier, Stephane
    Naghavi, Morteza
    Kakadiaris, Ioannis A.
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (03): : 299 - 306
  • [5] Automatic image-based gating for 4D ultrasound
    Karadayi, Kerem
    Hayashi, Tetsuya
    Kim, Yongmin
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 4675 - +
  • [6] Image data compression based on non-negative incoherent imaging systems
    Duadi, Hamootal
    Lohmann, Adolf W.
    Zalevsky, Zeev
    APPLIED OPTICS, 2010, 49 (30) : 5713 - 5720
  • [7] Dispersion Constraint Based Non-negative Sparse Coding Model
    Wang, Xin
    Wang, Can
    Shang, Li
    Sun, Zhan-Li
    NEURAL PROCESSING LETTERS, 2016, 43 (02) : 603 - 609
  • [8] Dispersion constraint based non-negative sparse coding algorithm
    Shang, Li
    Wang, Xin
    Sun, Zhan-Li
    NEUROCOMPUTING, 2016, 188 : 253 - 261
  • [9] Dispersion Constraint Based Non-negative Sparse Coding Model
    Xin Wang
    Can Wang
    Li Shang
    Zhan-Li Sun
    Neural Processing Letters, 2016, 43 : 603 - 609
  • [10] Image fusion based on non-negative matrix factorization
    Zhang, JY
    Wei, L
    Miao, QG
    Wang, Y
    ICIP: 2004 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1- 5, 2004, : 973 - 976