Spatial and temporal variability in outdoor, indoor, and personal PM2.5 exposure

被引:91
|
作者
Adgate, JL
Ramachandran, G
Pratt, GC
Waller, LA
Sexton, K
机构
[1] Univ Minnesota, Sch Publ Hlth, Div Environm & Occupat Hlth, Minneapolis, MN 55455 USA
[2] Minnesota Pollut Control Agcy, St Paul, MN 55155 USA
[3] Emory Univ, Rollins Sch Publ Hlth, Dept Biostat, Atlanta, GA 30322 USA
关键词
particulate matter; urban; monitoring; season; human exposure;
D O I
10.1016/S1352-2310(02)00326-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Outdoor, indoor and personal PM2.5 measurements were made in a population of nonsmoking adults from three communities in the Minneapolis-St. Paul metropolitan area between April and November 1999. Thirty-two healthy adult subjects (23 females, 9 males; mean age 42 +/- 10, range: 24-64 yr) were monitored for 2-15 days during the spring, summer, and fall monitoring seasons. Twenty-four hour average gravimetric PM2.5 samples were collected using a federal reference monitor (Anderson RAAS2.5-300) located at outdoor (O) central sites in the Battle Creek (BCK), East St. Paul (ESP) and Phillips (PHI) communities. Concurrent 24-h average indoor (1) and personal (P), and a limited number of outdoor-at-home (O@H) samples were collected using inertial impactors (PEM(TM) Model 200, MSP, Inc). The O (geometric mean {GM} = 8.6; n = 271; range: 1.0-41 mug/m(3)) were lower than I concentrations (GM = 10.7; n = 294; range 1.3-131 mug/m(3)), which were lower than P concentrations (GM =19.0; n = 332; range 2.2-298 mug/m(3)). Correlation coefficients between O concentrations in the three communities were high and measured GM O levels in BCK were significantly lower than ESP, most likely because of local sources, but GM concentrations in PHI were not significantly different from BCK or ESP. On days with paired samples (n = 29), O concentrations were significantly lower (mean difference 2.9 mug/m(3); p = 0.026) than O@H measurements (GM =11.3; range: 3.5-33.8 mug/m(3)), likely due to local sources in communities. Observed I and P concentrations were more variable, probably because of residential central air conditioning and hours of household ventilation for I and P, and occupational and environmental tobacco smoke exposures outside the residence for P. Across all individuals and days the median PM2.5 "personal cloud" was 5.7mug/m(3), but the mean of the average for each participant was 15.7 mug/m(3), with very low values in participants who did not work outside the home and much higher values in subjects with active lifestyles. Across all households and individuals the correlation between P and O concentrations was not significant, but the overall I-O correlation (0.27) and P-I correlation (0.51) were significant (p<0.05). Relatively little spatial variability was observed in O PM2.5 concentrations across the three communities compared to the variability associated with I and P samples, and the measured O levels were relatively low compared to other large metropolitan areas in the United States. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3255 / 3265
页数:11
相关论文
共 50 条
  • [1] Personal exposure monitoring of PM2.5 in indoor and outdoor microenvironments
    Steinle, Susanne
    Reis, Stefan
    Sabel, Clive E.
    Semple, Sean
    Twigg, Marsailidh M.
    Braban, Christine F.
    Leeson, Sarah R.
    Heal, Mathew R.
    Harrison, David
    Lin, Chun
    Wu, Hao
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 508 : 383 - 394
  • [2] Longitudinal variability in outdoor, indoor, and personal PM2.5 exposure in healthy non-smoking adults
    Adgate, JL
    Ramachandran, G
    Pratt, GC
    Waller, LA
    Sexton, K
    [J]. ATMOSPHERIC ENVIRONMENT, 2003, 37 (07) : 993 - 1002
  • [3] Determinants of indoor and personal exposure to PM2.5 of indoor and outdoor origin during the RIOPA study
    Meng, Qing Yu
    Spector, Dalia
    Colome, Steven
    Turpin, Barbara
    [J]. ATMOSPHERIC ENVIRONMENT, 2009, 43 (36) : 5750 - 5758
  • [4] Contribution of indoor and outdoor environments to PM2.5 personal exposure of children -: VESTA study
    Gauvin, S
    Reungoat, P
    Cassadou, S
    Déchenaux, J
    Momas, I
    Just, J
    Zmirou, D
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2002, 297 (1-3) : 175 - 181
  • [5] Personal, indoor and outdoor PM2.5 and its elemental composition associated with heart rate variability
    de Hartog, JJ
    Lanki, T
    Janssen, N
    Hoek, G
    Pekkanen, J
    Timonen, K
    Tarkiainen, T
    Peters, A
    Brunekreef, B
    [J]. EPIDEMIOLOGY, 2002, 13 (04) : S126 - S126
  • [6] Source apportionment of indoor, outdoor and personal PM2.5 exposure of pregnant women in Barcelona, Spain
    Minguillon, M. C.
    Schembari, A.
    Triguero-Mas, M.
    de Nazelle, A.
    Dadvand, P.
    Figueras, F.
    Salvado, J. A.
    Grimalt, J. O.
    Nieuwenhuijsen, M.
    Querol, X.
    [J]. ATMOSPHERIC ENVIRONMENT, 2012, 59 : 426 - 436
  • [7] Indoor, outdoor, and personal exposure to PM2.5 and their bioreactivity among healthy residents of Hong Kong
    Chen, Xiao-Cui
    Chuang, Hsiao-Chi
    Ward, Tony J.
    Tian, Linwei
    Cao, Jun-Ji
    Ho, Steven Sai-Hang
    Lau, Ngar-Cheung
    Hsiao, Ta-Chih
    Yim, Steve H. L.
    Ho, Kin-Fai
    [J]. ENVIRONMENTAL RESEARCH, 2020, 188
  • [8] Does the elemental composition of indoor and outdoor PM2.5 accurately represent the elemental composition of personal PM2.5?
    Brokamp, Cole
    Rao, M. B.
    Fan, Zhihua
    Ryan, Patrick H.
    [J]. ATMOSPHERIC ENVIRONMENT, 2015, 101 : 226 - 234
  • [9] Spatial and temporal variability of urban cyclists' exposure to PM2.5 in Medellin, Colombia
    Martinez, Jenny
    Morales, Yris Olaya
    Kumar, Prashant
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2024, 15 (01)
  • [10] Personal exposure and indoor PM2.5 concentrations in an urban population
    Mohammadyan, M
    Ashmore, M
    [J]. INDOOR AND BUILT ENVIRONMENT, 2005, 14 (3-4) : 313 - 320