A size-matching heterotopic aortic valve implantation model in the rat

被引:12
|
作者
Oei, FBS
Welters, MJP
Bonthuis, F
Vaessen, LMB
Marquet, RL
Zondervan, PE
Weimar, W
Bogers, AJJC
机构
[1] Univ Rotterdam Hosp, Dept Thorac Surg, NL-3015 GD Rotterdam, Netherlands
[2] Univ Rotterdam Hosp, Dept Expt Surg, NL-3015 GD Rotterdam, Netherlands
[3] Univ Rotterdam Hosp, Dept Pathol, NL-3015 GD Rotterdam, Netherlands
[4] Univ Rotterdam Hosp, Dept Internal Med 1, NL-3015 GD Rotterdam, Netherlands
关键词
implantation model; aortic valves; rejection; rat;
D O I
10.1006/jsre.1999.5763
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Structural failure of cardiac valve allografts may be related to technical factors such as size mismatch, resulting in early intimal proliferation and fibrosis or immunological reactions against the transplanted valves, featuring lymphocytic infiltration. Objective, To develop a heterotopic aortic valve implantation model in the rat to study the immunological factors leading to graft failure in the setting of a technical adaptation for size mismatch. Methods. Syngeneic (WAG-WAG or DA-DA) and allogeneic (WAG-BN or WAG-DA) rat strain combinations were used to study the effect of the allogeneic response on valve properties. An end-to-side anastomosis was made between the U-shaped aortic root graft and the recipient's abdominal aorta to resolve the problems of size matching. Results. No animals suffered from ischemic or neurological complications during the study period. One hundred percent survival and patency of the aortic grafts were achieved at the end of a 21-day observation period. In the syngeneic group 9 of 10 valves were still competent when assessed during retrograde injection. In contrast, 2 of 10 allogeneic valve grafts were competent on postoperative Day 21, Microscopic evaluation revealed no fibrosis or intimal thickening in the syngeneic valve grafts while the allogeneic valve grafts demonstrated rejection-like morphology, Conclusion. The absence of fibrosis and intimal thickening in the syngeneic transplanted valve grafts indicates that this implantation model is not influenced by nonimmunological-based structural changes. Therefore, this new model enables us to study the association between donor-directed immune responses and allograft degeneration in a technically unbiased manner. (C) 1999 Academic Press.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 50 条
  • [1] Heterotopic implantation of a porcine bioprosthetic heart valve in a dog with aortic valve endocarditis
    Arai, Shiori
    Wright, Bonnie D.
    Miyake, Yukari
    Boon, June A.
    Orton, E. Christopher
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2007, 231 (05): : 727 - 730
  • [2] A new model for heterotopic aortic valve transplantation
    Zhou, ZY
    Golshani, SD
    Wellisz, T
    Rosso, RF
    Nimni, ME
    Reinisch, JF
    [J]. TRANSPLANTATION, 1997, 64 (02) : 228 - 232
  • [3] A model of heterotopic aortic valve replacement: A critique
    Silverman, Norman A.
    [J]. JOURNAL OF SURGICAL RESEARCH, 2007, 141 (02) : 133 - 133
  • [4] Aortic valve regurgitation after heterotopic heart transplantation: Percutaneous treatment with transcatheter aortic valve implantation
    Gopalamurugan, A. B.
    Reinthaler, Markus
    Mullen, Michael J.
    Gerber, Robert T.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (07): : 771 - 772
  • [5] Impact of valve size on outcome after transcatheter aortic valve implantation
    Stastny, L.
    Kofler, M.
    Wachter, K.
    Dumfarth, J.
    Friedrich, G.
    Metzler, B.
    Grimm, M.
    Baumbach, H.
    Bonaros, N.
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 134 - 134
  • [6] ATTITUDE AND DISTANCE-ESTIMATION AS VARIABLES IN SIZE-MATCHING
    JENKIN, N
    HYMAN, R
    [J]. AMERICAN JOURNAL OF PSYCHOLOGY, 1959, 72 (01): : 68 - 76
  • [7] A Model Aortic Valve Bioprosthesis for Sutureless Implantation
    Zhuravleva I.Y.
    Bogachev-Prokophiev A.V.
    Timchenko T.P.
    Trebushat D.V.
    Mayorov A.P.
    Goncharenko A.M.
    Astapov D.A.
    Nushtaev D.V.
    Demidov D.P.
    [J]. Zhuravleva, I. Yu. (juravl_irina@mail.ru), 1600, Springer Science and Business Media, LLC (51): : 170 - 174
  • [8] Chronic orthotopic aortic valve implantation model
    Rakow, N
    Nelson, D
    Boldt, C
    Pfenning, K
    McClay, C
    Waskiewicz, J
    Shecterle, L
    Cyr, JS
    [J]. JOURNAL OF HEART VALVE DISEASE, 2000, 9 (06): : 822 - 826
  • [9] Requirement of Small Size of Prosthetic Aortic Valve in Asian Population; Implication to Select Valve Size for Transcatheter Aortic Valve Implantation in Elderly
    Saji, Mike
    Takayama, Morimasa
    Tobaru, Tetsuya
    Tabata, Minoru
    Nakata, Jun
    Watanabe, Hiroyuki
    Takanashi, Shuichiro
    Sumiyoshi, Tetsuya
    Tomoike, Hitonobu
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B205 - B205
  • [10] Spleen Size and Thrombocytopenia After Transcatheter Aortic Valve Implantation
    Sugiura, Atsushi
    Treiling, Louisa
    Al-Kassou, Baravan
    Shamekhi, Jasmin
    Wilde, Nihal
    Sinning, Jan-Malte
    Zimmer, Sebastian
    Kuetting, Daniel
    Oldenburg, Johannes
    Poetzsch, Bernd
    Nickenig, Georg
    Sedaghat, Alexander
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2021, 157 : 85 - 92