Effects of an Automated External Defibrillator With Additional Video Instructions on the Quality of Cardiopulmonary Resuscitation

被引:2
|
作者
Ettl, Florian [1 ]
Fischer, Eva [1 ,2 ]
Losert, Heidrun [1 ]
Stumpf, Dominik [3 ]
Ristl, Robin [4 ]
Ruetzler, Kurt [5 ]
Greif, Robert [6 ,7 ]
Fischer, Henrik [7 ]
机构
[1] Med Univ Vienna, Dept Emergency Med, Vienna, Austria
[2] Klin Donaustadt, Dept Anaesthesiol & Intens Care, Vienna, Austria
[3] Ordensklinikum Linz Hosp Sisters Charity, Dept Anaesthesia & Intens Care, Linz, Austria
[4] Med Univ Vienna, Ctr Med Stat Informat & Intelligent Syst, Vienna, Austria
[5] Cleveland Clin, Dept Outcomes Res, Cleveland, OH 44106 USA
[6] Univ Bern, Bern Univ Hosp, Dept Anaesthesiol & Pain Med, Inselspital, Bern, Switzerland
[7] Sigmund Freud Private Univ, Sch Med, Vienna, Austria
关键词
resuscitation; basic life support; automated external defbrillator; quality; video instructions;
D O I
10.3389/fmed.2021.640721
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim of the Study: The aim was to compare cardiopulmonary resuscitation (CPR) quality of an automated external defibrillator (AED) with and without additional video instruction during basic life support (BLS) by laypersons. Methods: First-year medical students were randomized either to an AED with audio only or audio with additional video instructions during CPR. Each student performed 4 min of single-rescuer chest compression only BLS on a manikin (Ambu Man C, Ballerup, Denmark) using the AED. The primary outcome was the effective compression ratio during this scenario. This combined parameter was used to evaluate the quality of chest compressions by multiplying compressions with correct depth, correct hand position, and complete decompression by flow time. Secondary outcomes were percentages of incomplete decompression and hand position, mean compression rate, time-related parameters, and subjective assessments. Results: Effective compression ratio did not differ between study groups in the overall sample (p = 0.337) or in students with (p = 0.953) or without AED experience (p = 0.278). Additional video instruction led to a higher percentage of incorrect decompressions (p = 0.014). No significant differences could be detected in time-related resuscitation parameters. An additional video was subjectively rated as more supporting (p = 0.001). Conclusions: Audio-video instructions did not significantly improve resuscitation quality in these laypersons despite that it was felt more supportive. An additional video to the verbal AED prompts might lead to cognitive overload. Therefore, future studies might target the influence of the video content and the potential benefits of video instructions in specific populations.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Predictors of cardiopulmonary resuscitation and automated external defibrillator skill retention
    Riegel, B
    Birnbaum, A
    Aufderheide, TP
    Thode, HC
    Henry, MC
    Van Ottingham, L
    Swor, R
    [J]. AMERICAN HEART JOURNAL, 2005, 150 (05) : 927 - 932
  • [2] Automated external defibrillator use during cardiopulmonary resuscitation during flight
    Lapostolle, F
    Mahaut, JM
    Crocheton, N
    Levasseur, J
    Adnet, F
    [J]. ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2003, 22 (03): : 235 - 237
  • [3] Effects and limitations of an automated external defibrillator with audiovisual feedback for cardiopulmonary resuscitation: a randomized manikin study
    H Fischer
    J Gruber
    S Neuhold
    S Frantal
    E Hochbrugger
    B Steinlechner
    R Greif
    [J]. Critical Care, 15 (Suppl 1):
  • [4] Automated External Defibrillator with Real-Time Audiovisual Feedback System Improves the Quality of Cardiopulmonary Resuscitation
    Hayashi, Kenji
    Ushikoshi, Hiroaki
    Matsumaru, Naoki
    Nachi, Sho
    Nachi, Hikaru
    Morishita, Kentaro
    Sugihara, Hiroko
    Fukao, Ayumi
    Toyoda, Izumi
    Ogura, Shinji
    [J]. CIRCULATION, 2014, 130
  • [5] Rate of bystander cardiopulmonary resuscitation and feasibility of automated external defibrillator in lay population
    Kleemann, T.
    Strauss, M.
    Dyck, N.
    Becker, T.
    Skarlos, A.
    Seidl, K.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 645 - 646
  • [6] Training Athletes and School Personnel in Automated External Defibrillator Application and Cardiopulmonary Resuscitation
    Kang, GuanYang
    Zhang, HuiQing
    [J]. AMERICAN JOURNAL OF MEDICINE, 2019, 132 (12): : E860 - E860
  • [7] THE USE OF CARDIOPULMONARY RESUSCITATION AND THE AUTOMATED EXTERNAL DEFIBRILLATOR IN THE PRACTICE OF SPORTS PHYSICAL THERAPY
    Smith, Danny
    Hoogenboom, Barb
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2011, 6 (03): : 267 - 270
  • [8] ABC of resuscitation - The automated external defibrillator
    Liddle, R
    Davies, CS
    Colquhoun, M
    Handley, AJ
    [J]. BRITISH MEDICAL JOURNAL, 2003, 327 (7425): : 1216 - 1218
  • [9] Cardiopulmonary Resuscitation/Automated External Defibrillator Olympic Competition Enhances Resuscitation Skills in High School Students
    Haley, Danielle M.
    Dugan, Noreen P.
    Hall, Christopher N.
    Guo, Rong
    Nadkarni, Vinay
    Vetter, Victoria L.
    [J]. CIRCULATION, 2011, 124 (21)
  • [10] Does the Real-Time Audio Feedback From an Automated External Defibrillator Enhance Cardiopulmonary Resuscitation Quality During Emergency Resuscitation?
    O'Hare, Peter
    Di Maio, Rebecca
    Torney, Hannah
    McIntyre, Colette
    McCanny, Paul
    Adgey, Jennifer
    [J]. CIRCULATION, 2013, 128 (22)