Determination of estrogens in environmental water samples using 1,3-dipentylimidazolium hexafluorophosphate ionic liquid as extraction solvent in dispersive liquid-liquid microextraction

被引:25
|
作者
Socas-Rodriguez, Barbara [1 ]
Hernandez-Borges, Javier [1 ]
Asensio-Ramos, Maria [2 ]
Herrera-Herrera, Antonio V. [3 ]
Palenzuela, Jose A. [4 ]
Angel Rodriguez-Delgado, Miguel [1 ]
机构
[1] Univ La Laguna, Fac Quim, Dept Quim Analit Nutr & Bromatol, San Cristobal la Laguna 38206, Tenerife, Spain
[2] Inst Volcanol Canarias INVOLCAN, Tenerife, Spain
[3] Univ La Laguna, Serv Gen Apoyo Invest SEGAI, San Cristobal la Laguna 38206, Tenerife, Spain
[4] Univ La Laguna, Dept Quim Organ, Inst Univ Bioorgan Antonio Gonzalez, San Cristobal la Laguna 38206, Tenerife, Spain
关键词
Dispersive liquid-phase microextraction; Estrogens; HPLC; Ionic liquid; Mycotoxin; TANDEM MASS-SPECTROMETRY; WASTE-WATER; FLUORESCENCE DETECTION; PHASE MICROEXTRACTION; MICRO-EXTRACTION; STEROID-HORMONES; TREATMENT PLANTS; SURFACE WATERS; CHROMATOGRAPHY; METABOLITES;
D O I
10.1002/elps.201400024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, the potential of a symmetric dialkyl-substituted ionic liquid (IL), 1,3-dipenthylimidazolium hexafluorophosphate ([PPIm][PF6]), as extraction solvent in dispersive liquid-liquid microextraction (DLLME) has been studied for the analysis of a group of three natural (estriol, 17-estradiol, and 17-estradiol) and four synthetic (17-ethynylestradiol, diethylstibestrol, dienestrol, and hexestrol) estrogenic compounds as well as one mycotoxin with estrogenic activity (zearalenone) in different types of water samples (Milli-Q, mineral, and wastewater). Separation, determination, and quantification were developed by HPLC-DAD and a fluorescence detector (FD) connected in series. Factors influencing the IL-DLLME procedure (sample pH, amount of IL, type and volume of disperser solvent, ionic strength, and assistance of vortex agitation) were investigated and optimized by means of a step-by-step approach. Once the optimum extraction conditions were established (10 mL of water at pH 8, 60 mg of [PPIm][PF6], 500 L of ACN as disperser solvent and vortex agitation for 1 min), the calibration curves of the whole method (IL-DLLME-HPLC-DAD/FD) were obtained and precision and accuracy were evaluated. It was demonstrated that the developed methodology was repeatable, accurate, and selective with limits of detection in the 0.30-0.57 g/L and 13.8-37.1 g/L range for FD and DAD, respectively. Relative recovery values were higher than 85% for the different types of water samples and the Student's t test demonstrated that there were not significant differences between the added and the found concentration.
引用
收藏
页码:2479 / 2487
页数:9
相关论文
共 50 条
  • [1] Dispersive liquid-liquid microextraction of pesticides and metabolites from soils using 1,3-dipentylimidazolium hexafluorophosphate ionic liquid as an alternative extraction solvent
    Asensio-Ramos, Maria
    Hernandez-Borges, Javier
    Ravelo-Perez, Lidia M.
    Afonso, Maria M.
    Antonio Palenzuela, J.
    Angel Rodriguez-Delgado, Miguel
    ELECTROPHORESIS, 2012, 33 (9-10) : 1449 - 1457
  • [2] Determination of Pyrethroid Pesticides in Environmental Samples using Ionic Liquid Dispersive Liquid-Liquid Microextraction
    Wu, Tong
    Liu, Yu
    Yang, Zhonghua
    Gao, Haixiang
    Zhou, Zhiqiang
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (07) : 1327 - 1333
  • [3] Dispersive liquid-liquid microextraction of zinc from environmental water samples using ionic liquid
    Preethi, A.
    Vijayalakshmi, R.
    Lakshmi, Brinda A.
    CHEMICAL ENGINEERING COMMUNICATIONS, 2021, 208 (06) : 914 - 923
  • [4] Dispersive liquid-liquid microextraction for four phenolic environmental estrogens in water samples followed by determination using capillary electrophoresis
    Liu, Junying
    Lu, Wenhui
    Liu, Huitao
    Wu, Xiaqing
    Li, Jinhua
    Chen, Lingxin
    ELECTROPHORESIS, 2016, 37 (19) : 2502 - 2508
  • [5] DETERMINATION OF ESTROGENS IN WATER SAMPLES BY IONIC LIQUID-BASED DISPERSIVE LIQUID-LIQUID MICROEXTRACTION COMBINED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
    Wu, Cui-Qin
    Chen, Di-Yun
    Feng, Yin-Si
    Deng, Hong-Mei
    Liu, Yong-Hui
    Zhou, Ai-Ju
    ANALYTICAL LETTERS, 2012, 45 (14) : 1995 - 2005
  • [6] Determination of medroxyprogesterone in water samples using dispersive liquid-liquid microextraction with low solvent consumption
    Shaofei Xie
    Bingren Xiang
    Ming Zhang
    Haishan Deng
    Microchimica Acta, 2010, 168 : 253 - 258
  • [7] Determination of medroxyprogesterone in water samples using dispersive liquid-liquid microextraction with low solvent consumption
    Xie, Shaofei
    Xiang, Bingren
    Zhang, Ming
    Deng, Haishan
    MICROCHIMICA ACTA, 2010, 168 (3-4) : 253 - 258
  • [8] Determination of four heterocyclic insecticides by ionic liquid dispersive liquid-liquid microextraction in water samples
    Liu, Yu
    Zhao, Ercheng
    Zhu, Wentao
    Gao, Haixiang
    Zhou, Zhiqiang
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (06) : 885 - 891
  • [9] Dispersive liquid-liquid microextraction based on ionic liquid and spectrophotometric determination of mercury in water samples
    Gharehbaghi, Maysam
    Shemirani, Farzaneh
    Baghdadi, Majid
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (01) : 21 - 33
  • [10] Dispersive liquid-liquid microextraction using extraction solvent lighter than water
    Farajzadeh, Mir Ali
    Seyedi, Seyed Esmaeil
    Shalamzari, Mohammad Safi
    Bamorowat, Mehdi
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (18) : 3191 - 3200