Choroidal Variations in Diabetic Macular Edema: Fluorescein Angiography and Optical Coherence Tomography

被引:13
|
作者
Wang, Xiangning [1 ]
Li, Shuting [1 ]
Li, Wei [1 ]
Hua, Yanjun [1 ]
Wu, Qiang [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Ophthalmol, Shanghai, Peoples R China
[2] Shanghai Key Lab Diabet Mellitus, Shanghai, Peoples R China
关键词
Choroid; diabetic macular edema; enhanced depth imaging; fluorescein angiography; optical coherence tomography; HEALTHY-SUBJECTS; THICKNESS; RETINOPATHY; VOLUME; SEVERITY; PATTERNS;
D O I
10.1080/02713683.2017.1370115
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purposes: To (i) evaluate variations in choroidal thickness (CT) and choroidal volume (CV) in diabetic macular edema (DME), as demonstrated by fluorescein angiography (FA) and enhanced depthimaging (EDI) optical coherence tomography (OCT) (EDI-OCT) and (ii) correlate these variations with visual acuity. Methods: This study was a retrospective observational case series of patients with diabetic retinopathy (DR) and DME. The study groups comprised 77 DR patients (n = 87), all of whom underwent color fundus photography, FA, and OCT on the same day. The control group comprised 25 age-matched healthy individuals (n = 50 eyes). CT was measured by manual segmentation (EDI-OCT built-in automated retinal segmentation software). Variations in CT in DME patterns were analyzed. Results: We studied a total of 87 eyes from patients with DR, including 50 eyes from 25 patients with DME (DME group) and 37 eyes from 22 patients without DME (non-DME group). For DME-group patients, mean subfoveal choroidal thickness (SFCT) and total CV (TCV) were 258.8 +/- 81.7 mu m and 6.6 +/- 1.8 mm(3), respectively. For non-DME group patients, mean SFCT and TCV values were 247.6 +/- 73.3 mu m and 6.6 +/- 1.6 mm(3), respectively. SFCT and TCV values for both groups were significantly lower than for healthy controls (294.3 +/- 87.6 mu m and 7.7 +/- 1.8 mm(-3) respectively) (p = 0.040 and 0.019, respectively). CTs varied according to morphological FA and OCT patterns of DME, but did not differ significantly (p > 0.05). Conclusions: CT and CV in DR patients were decreased compared with healthy controls. CTs did not differ significantly between DME patterns demonstrated by OCT and FA.
引用
收藏
页码:102 / 108
页数:7
相关论文
共 50 条
  • [1] Choroidal Variations in Diabetic Macular Edema: Fluorescein Angiography and Optical Coherence Tomography (Vol 43, Pg 102, 2017)
    Xiangning, W.
    Shuting, L.
    Wei, L.
    Yanjun, H.
    Qiang
    CURRENT EYE RESEARCH, 2018, 43 (01)
  • [2] Correlation between optical coherence tomography and fluorescein angiography findings in diabetic macular edema
    Otani, Tomohiro
    Kishi, Shoji
    OPHTHALMOLOGY, 2007, 114 (01) : 104 - 107
  • [3] Optical coherence tomography angiography analysis of choroidal microvasculature in various forms of diabetic macular edema
    Sargues, L. Remoli
    Navarro, V. Castro
    Adsuara, C. Monferrer
    Palop, C. Navarro
    Hernandez, J. Montero
    Taulet, E. Cervera
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (01):
  • [4] Discrepancies Between Fluorescein Angiography and Optical Coherence Tomography in Macular Edema in Uveitis
    Norel, Jeannette Ossewaarde-Van
    Camfferman, Laurens P.
    Rothova, Aniki
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (02) : 233 - 239
  • [5] Fluorescein Angiography versus Optical Coherence Tomography for Diagnosis of Uveitic Macular Edema
    Kempen, John H.
    Sugar, Elizabeth A.
    Jaffe, Glenn J.
    Acharya, Nisha R.
    Dunn, James P.
    Elner, Susan G.
    Lightman, Susan L.
    Thorne, Jennifer E.
    Vitale, Albert T.
    Altaweel, Michael M.
    OPHTHALMOLOGY, 2013, 120 (09) : 1852 - 1859
  • [6] FLUORESCEIN ANGIOGRAPHY VERSUS OPTICAL COHERENCE TOMOGRAPHY-GUIDED PLANNING FOR MACULAR LASER PHOTOCOAGULATION IN DIABETIC MACULAR EDEMA
    Kozak, Igor
    El-Emam, Sharif Y.
    Cheng, Lingyun
    Bartsch, Dirk-Uwe
    Chhablani, Jay
    Freeman, William R.
    Arevalo, J. Fernando
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (08): : 1600 - 1605
  • [7] Comparison of Optical Coherence Tomography Angiography and Fluorescein Angiography for the Identification of Retinal Vascular Changes in Eyes With Diabetic Macular Edema
    Peres, Murilo Bertazzo
    Kato, Renata Tiemi
    Kniggendorf, Vinicius F.
    Cole, Emily D.
    Onal, Sumru
    Torres, Elmar
    Louzada, Ricardo
    Belfort, Rubens, Jr.
    Duker, Jay S.
    Novais, Eduardo A.
    Regatieri, Caio V.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2016, 47 (11): : 1013 - 1019
  • [8] Evaluation of diabetic macular ischemia using Optical Coherence Tomography Angiography and Fluorescein Angiography
    Trenado Luna, Jeniffer
    Rojas Juarez, Sergio
    Ramirez Estudillo, Abel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [9] Clinical application of optical coherence tomography angiography in diabetic macular edema
    Lv, Meng
    Li, Tuo
    Li, Yin
    AFRICAN HEALTH SCIENCES, 2023, 23 (02) : 484 - 489
  • [10] Detection of diabetic foveal edema with biomicroscopy, fluorescein angiography and optical coherence tomography
    Hannouche, Rosana Zacarias
    Avila, Marcos Pereira
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2008, 71 (05) : 759 - 763