Harmonic Response Analysis of Tank Design Effect on Ultrasonic Cleaning Process

被引:8
|
作者
Phophayu, Suchada [1 ]
Kliangklom, Ketmanee [1 ]
Thongsri, Jatuporn [1 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Coll Adv Mfg Innovat, Comp Simulat Engn Res Grp, Bangkok 10520, Thailand
关键词
acoustic pressure; cavitation; harmonic response analysis; horn transducer; simulation; ultrasonic cleaning; vibration analysis;
D O I
10.3390/fluids7030099
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Several ultrasonic cleaning tanks (UCTs) had a problem: a manufacturer complained that there were damages to cleaning objects, they were unclarified, and it needed to be abruptly solved. To investigate and solve the problem, a small UCT filled with 3.92 L of water, with a frequency of 28 kHz, two horn transducers, and a total power of 100 W was built for simulation and experiment. A built tank body material of UCT can be adjustable to acrylic, glass, and stainless steel. Since the cavitation causing the cleaning relates to acoustic pressure, harmonic response analysis (HRA) in ANSYS software was employed to calculate the acoustic pressure inside the UCT for different designs such as mentioned materials, power, thickness, volume, and frequency. The HRA results revealed uneven acoustic pressure depending on the tank designs, consistent with foil corrosion and power concentration experiments. Furthermore, using the tank body material with acrylic, glass, and stainless steel provided the highest, moderate, and lowest acoustic pressure levels, respectively. The uneven acoustic pressure resulted from the differences in material transmission coefficients. In addition, the damage occurred because of improper tank design, resulting in excessive acoustic pressure. Therefore, the tank design is indispensable in designing high-efficiency UCTs to reduce damage and meet customer requirements.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Improved Design of Ultrasonic Cleaning Tank Using Harmonic Response Analysis in ANSYS
    Tangsopa, W.
    Keawklan, T.
    Kesngam, K.
    Ngaochai, S.
    Thongsri, J.
    2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND RENEWABLE ENERGY (ICERE 2018), 2018, 159
  • [2] Development of an industrial ultrasonic cleaning tank based on harmonic response analysis
    Tangsopa, Worapol
    Thongsri, Jatuporn
    ULTRASONICS, 2019, 91 : 68 - 76
  • [3] A Novel Ultrasonic Cleaning Tank Developed by Harmonic Response Analysis and Computational Fluid Dynamics
    Tangsopa, Worapol
    Thongsri, Jatuporn
    METALS, 2020, 10 (03)
  • [4] Development of a Small Ultrasonic Cleaning Bath based on Harmonic Response Analysis
    Worradechaudom, Warakorn
    Chaiaiad, Chatchapat
    Thongsri, Jatuporn
    2024 INTERNATIONAL TECHNICAL CONFERENCE ON CIRCUITS/SYSTEMS, COMPUTERS, AND COMMUNICATIONS, ITC-CSCC 2024, 2024,
  • [5] A Dual Frequency Ultrasonic Cleaning Tank Developed by Transient Dynamic Analysis
    Tangsopa, Worapol
    Thongsri, Jatuporn
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 20
  • [6] Finite element modeling and harmonic analysis of miniature transducer for ultrasonic cleaning
    Liang, Li
    Chen, Weilin
    Zhang, Tiemin
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2013, 33 (SUPPL.1): : 61 - 64
  • [7] Optimization Design and Flow Field Characteristics Study of Cleaning Process Tank for Wafer Wet
    Xie, Zhenmin
    Chen, Zhao
    Liu, Guangjie
    Li, Changcheng
    Li, Guosen
    Li, Ge
    2024 25TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY, ICEPT, 2024,
  • [8] Monitoring the cleaning process in ultrasonic baths
    Köchel, Matthias
    JOT, Journal fuer Oberflaechentechnik, 2023, 63 : 28 - 29
  • [9] PROCESS-CONTROL ULTRASONIC CLEANING
    PUSKAS, WL
    FERRELL, GW
    PROCEEDING OF THE TECHNICAL PROGRAM OF NEPCON WEST 89, VOLS 1 AND 2, 1989, : 1017 - 1023
  • [10] Design and Development of Tank Cleaning Inspection Robot
    Shanmugasundar, G.
    Gurudarshan, S.
    Kirubaharan, N.
    Sundar, M. S.
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 1009 - 1012