Label-free Separation of Circulating Tumor Cells Using a Self-Amplified Inertial Focusing (SAIF) Microfluidic Chip

被引:26
|
作者
Abdulla, Aynur [1 ]
Zhang, Ting [1 ]
Ahmad, Khan Zara [1 ]
Li, Shanhe [1 ]
Lou, Jiatao [2 ]
Ding, Xianting [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Inst Personalized Med, State Key Lab Oncogenes & Related Genes, Shanghai 200030, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Chest Hosp, Dept Lab Med, Shanghai 200030, Peoples R China
基金
中国国家自然科学基金;
关键词
CANCER-CELLS; BLOOD; MICROCHANNEL;
D O I
10.1021/acs.analchem.0c03920
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Circulating tumor cells (CTCs) are rare cells existing in the bloodstream with a relatively low number, which facilitate as a predictor of cancer progress. However, it is difficult to obtain highly purified intact CTCs with desired viability due to the low percentage of CTCs among blood cells. In this work, we demonstrate a novel self-amplified inertial focused (SAIF) microfluidic chip that enables size-based, high-throughput, label-free separation of CTCs from a patient's blood. The SAIF chip introduced in this study demonstrated the feasibility of an extremely narrow zigzag channel (with 40 mu m channel width) connected with two expansion regions to effectively separate different-sized cells with amplified separation distance. The chip performance was optimized with different-sized polystyrene (PS) particles and blood cells spiked with three different types of cancer cells. The separation efficiencies for blood cells and spiked cancer cells are higher than 80%. Recovery rates of cancer cells were tested by spiking 1500 lung cancer cells (A549), breast cancer cells (MCF-7), and cervical cancer cells (HeLa) separately to 3 mL 0.09% saline with 3 x 10(6) white blood cells (WBCs). The recovery rates for larger cells (MCF-7 and HeLa) were 79.1 and 85.4%, respectively. Viabilities of the cells harvested from outlets were all higher than 97% after culturing for 24, 48, and 72 h. The SAIF chip performance was further confirmed using the real clinical patient blood samples from four lung cancer patients. Theoretical force balance analysis in physics, computational simulations, and experimental observations indicate that the SAIF chip is simple but effective, and high-throughput separation CTCs can be readily achieved without complex structures.
引用
收藏
页码:16170 / 16179
页数:10
相关论文
共 50 条
  • [1] Optimal Parameter Configuration of a Microfluidic Chip for High-Throughput, Label-Free Circulating Tumor Cell Separation and Enrichment Based on Inertial Focusing
    Sun, Xiaoyi
    Ma, Yuqi
    Lu, Chunyang
    Cai, Ziwei
    Han, Jintao
    Wang, Zhigang
    Yang, Gen
    [J]. DIAGNOSTICS, 2023, 13 (23)
  • [2] Investigation on a cascaded inertial and acoustic microfluidic device for sheathless and label-free separation of circulating tumor cells
    Peng, Tao
    Qiang, Jun
    Yuan, Shuai
    [J]. PHYSICS OF FLUIDS, 2023, 35 (08)
  • [3] Label-Free Separation of Circulating Tumor Cells and Clusters by Alternating Frequency Acoustic Field in a Microfluidic Chip
    Zhang, Yan
    Zhang, Ziang
    Zheng, Dongbang
    Huang, Tuchen
    Fu, Qibin
    Liu, Yang
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (04)
  • [4] A micropillar array-based microfluidic chip for label-free separation of circulating tumor cells: The best micropillar geometry?
    Rahmanian, Mehdi
    Hematabad, Omid Sartipzadeh
    Askari, Esfandyar
    Shokati, Farhad
    Bakhshi, Atin
    Moghadam, Shiva
    Olfatbakhsh, Asiie
    Hashemi, Esmat Al Sadat
    Ahmadi, Mohammad Khorsand
    Naghib, Seyed Morteza
    Sinha, Nidhi
    Tel, Jurjen
    Amirabadi, Hossein Eslami
    den Toonder, Jaap M. J.
    Majidzadeh-A, Keivan
    [J]. JOURNAL OF ADVANCED RESEARCH, 2023, 47 : 105 - 121
  • [5] The label-free separation and culture of tumor cells in a microfluidic biochip
    Zhou, Jian
    Tu, Chunlong
    Liang, Yitao
    Huang, Bobo
    Fang, Yifeng
    Liang, Xiao
    Ye, Xuesong
    [J]. ANALYST, 2020, 145 (05) : 1706 - 1715
  • [6] Dielectrophoresis based Microfluidic chip for continuous label-free separation of cells
    Das, Debanjan
    Biswas, Karabi
    Das, Soumen
    [J]. 2015 9TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2015, : 728 - 732
  • [7] Label-free ferrohydrodynamic cell separation of circulating tumor cells
    Zhao, Wujun
    Cheng, Rui
    Jenkins, Brittany D.
    Zhu, Taotao
    Okonkwo, Nneoma E.
    Jones, Courtney E.
    Davis, Melissa B.
    Kavuri, Sravan K.
    Hao, Zhonglin
    Schroeder, Carsten
    Mao, Leidong
    [J]. LAB ON A CHIP, 2017, 17 (18) : 3097 - 3111
  • [8] Label-Free, High-Throughput Purification of Satellite Cells Using Microfluidic Inertial Separation
    Syverud, Brian C.
    Lin, Eric
    Nagrath, Sunitha
    Larkin, Lisa M.
    [J]. TISSUE ENGINEERING PART C-METHODS, 2018, 24 (01) : 32 - 41
  • [9] Label-free isolation of prostate circulating tumor cells using Vortex microfluidic technology
    Corinne Renier
    Edward Pao
    James Che
    Haiyan E. Liu
    Clementine A. Lemaire
    Melissa Matsumoto
    Melanie Triboulet
    Sandy Srivinas
    Stefanie S. Jeffrey
    Matthew Rettig
    Rajan P. Kulkarni
    Dino Di Carlo
    Elodie Sollier-Christen
    [J]. npj Precision Oncology, 1
  • [10] Label-free isolation of prostate circulating tumor cells using Vortex microfluidic technology
    Renier, Corinne
    Pao, Edward
    Che, James
    Liu, Haiyan E.
    Lemaire, Clementine A.
    Matsumoto, Melissa
    Triboulet, Melanie
    Srivinas, Sandy
    Jeffrey, Stefanie S.
    Rettig, Matthew
    Kulkarni, Rajan P.
    Di Carlo, Dino
    Sollier-Christen, Elodie
    [J]. NPJ PRECISION ONCOLOGY, 2017, 1