Water vapor cross-sensitivity of open path H2O/CO2 sensors

被引:0
|
作者
Kohsiek, W [1 ]
机构
[1] Royal Netherlands Meteorol Inst, NL-3730 AE De Bilt, Netherlands
关键词
D O I
10.1175/1520-0426(2000)017<0299:WVCSOO>2.0.CO;2
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
When measuring the flux of CO2 with an open-path infrared absorption sensor, cross-sensitivity by water vapor is a source of concern. This is particularly true ii the flux is small. such as over the sea. In this paper some possible mechanisms for cross-sensitivity are discussed. Pressure broadening by water vapor, and absorption and scattering by water adhered to the optics are the processes of major concern. Two types of open-path sensors were tested in a climate chamber for cross-sensitivity-one was constructed by the National Oceanic and Atmospheric Administration Atmospheric Turbulence and Diffusion Division (NOAA/ATDD) in Oak Ridge, Tennessee, and the other by the Royal Netherlands Meteorological Institute (KNMI). For the NOAA sensor it was found that cross-sensitivity is absent below 50% relative humidity, bur with increasing relative humidity the CO2 concentration apparently decreases. A possible explanation for this effect is scattering of radiation by water adhered to the optics. In the case of the KNMI sensor, the CO2 concentration apparently increases with increasing absolute humidity. This can be explained by pressure broadening. With this sensor the optics are heated and interference by water on the optics is not likely.
引用
收藏
页码:299 / 311
页数:13
相关论文
共 50 条
  • [1] Experimental evaluation of water vapour cross-sensitivity for accurate eddy covariance measurement of CO2 flux using open-path CO2/H2O gas analysers
    Kondo, Fumiyoshi
    Ono, Keisuke
    Mano, Masayoshi
    Miyata, Akira
    Tsukamoto, Osamu
    [J]. TELLUS SERIES B-CHEMICAL AND PHYSICAL METEOROLOGY, 2014, 66
  • [2] CROSS-SENSITIVITY OF VARIOUS DOPED STRONTIUM-TITANATE FILMS TO CO, CO2, H2, H2O AND CH4
    GERBLINGER, J
    LAMPE, U
    MEIXNER, H
    PERCZEL, IV
    GIBER, J
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) : 529 - 534
  • [3] Suppression of NO and SO2 cross-sensitivity in electrochemical CO2 sensors with filter layers
    Hong, HS
    Kim, JW
    Jung, SJ
    Park, CO
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01) : 71 - 79
  • [4] ADSORPTION OF CO2 AND H2O VAPOR ON ACTIVATED CARBONS
    STEWART, ML
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 38 - FUEL
  • [5] OXIDATION OF ZINC VAPOR IN MIXTURES OF CO/CO2/A AND H2/H2O/A
    CLARKE, JA
    FRAY, DJ
    [J]. JOM-JOURNAL OF METALS, 1976, 28 (12): : A33 - A33
  • [6] PHOTOIONIZATION CROSS SECTIONS OF CO2,A,H2, AND H2O
    WAINFAN, N
    WALKER, WC
    WEISSLER, GL
    [J]. PHYSICAL REVIEW, 1955, 98 (02): : 561 - 562
  • [7] The sensitivity of Diel CO2 and H2O vapor exchange of a tropical transitional forest to seasonal variation in meteorology and water availability
    Vourlitis, George L.
    Nogueira, Jose de Souza
    Priante Filho, Nicolau
    Hoeger, Wander
    Raiter, Fernando
    Biudes, Marcelo Sacardi
    Arruda, Jose Carlos
    Capistrano, Vinicius Buscioli
    Brito de Faria, Jorge Luiz
    Lobo, Francisco de Almeida
    [J]. EARTH INTERACTIONS, 2005, 9 : 1 - 23
  • [8] Effect of Water on CO2 Adsorption on CaNaY Zeolite: Formation of Ca2+(H2O)(CO2), Ca2+(H2O)(CO2)2 and Ca2+(H2O)2(CO2) Complexes
    Drenchev, Nikola L.
    Shivachev, Boris L.
    Dimitrov, Lubomir D.
    Hadjiivanov, Konstantin I.
    [J]. NANOMATERIALS, 2023, 13 (16)
  • [9] An open path H2O/CO2 gas analyzer for eddy correlation systems:: theory and design
    Kidd, G
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (11) : 2373 - 2388
  • [10] AN OPEN PATH, FAST RESPONSE INFRARED-ABSORPTION GAS ANALYZER FOR H2O AND CO2
    AUBLE, DL
    MEYERS, TP
    [J]. BOUNDARY-LAYER METEOROLOGY, 1992, 59 (03) : 243 - 256