共 7 条
Metabolism of a 14C/3H-labeled GABAA receptor partial agonist in rat, dog and human liver microsomes:: Evaluation of a dual-radiolabel strategy
被引:7
|作者:
Shaffer, Christopher L.
[1
]
Langer, Connie S.
[1
]
机构:
[1] Pfizer Inc, Groton New London Labs, Pfizer Global Res & Dev, Dept Pharmacokenet Pharmacodynam & Metab, Groton, CT 06340 USA
关键词:
in vitro drug metabolism;
dual-radiolabel compounds;
metabolite structure elucidation;
D O I:
10.1016/j.jpba.2006.11.022
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
The metabolism of 2-{[2-(3-fluoropyrid-2-yl)-1H-imidazol-1-yl]methyl}-1-propyl-5-cyano-1H-benzimidazole (1), a potent subtype-selective GABA(A) receptor partial agonist, was investigated in rat, dog and human liver microsomes. Due to its significant metabolic cleavage at C(8) observed in preliminary biotransformation studies with non-radiolabeled 1, both [(14)C]1 and [(3)H]1 were synthesized with respective radioisotopes placed on either side of C(8) to determine if all microsomal metabolites formed after C(8) N-dealkylation of I (or its core-intact metabolites) could be detected and quantified adequately. Both radiolabeled forms of 1, used separately in mono-radiolabel studies in cross-species microsomes and concomitantly in dual-radiolabel studies in rat microsomes, permitted the detection and quantification of all metabolites of 1, and a combination of radioactive and mass spectral data allowed structural elucidation of its Phase I metabolites. As expected, the sum of (14)C-only metabolites equaled that of (3)H-only metabolites in all incubations. In-line radiometric analysis worked extremely well (and was very reproducible) for quantifying either (14)C- or (3)H-compounds within separate incubations when using mono-radiolabeled 1. However, although the in-line radiodetector provided a comprehensive qualitative metabolic profile using dual-radiolabled 1, its inability to exclude completely (14)C- from (3)H-generated counts caused a degree of ambiguity pertaining to metabolite quantification. Thus, off-line liquid scintillation counting of collected dual-radiolabeled incubation I-C-fractions was employed to quantify, both (14)C- and (3)H-metabolites simultaneously, while in-line radiodetection was only used for qualitative analyses accompanying MS and MS/MS experiments. These studies demonstrated the analytical feasibility of using a dual-radiolabel approach for subsequent in vivo ADME studies with 1. (c) 2006 Elsevier B.V. All fights reserved.
引用
收藏
页码:1195 / 1205
页数:11
相关论文