Axial restraint effects on the fire resistance of composite columns encasing I-section steel

被引:45
|
作者
Huang, Zhan-Fei [1 ]
Tan, Kang-Hai [1 ]
Phng, Guan-Hwee [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Dept Struct & Mech, Singapore 639798, Singapore
关键词
axial restraint; fire resistance; fire tests; encased I-section steel stanchion;
D O I
10.1016/j.jcsr.2006.07.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental study of the axial restraint effect on fire resistance of four unprotected encased I-section composite columns. Axial restraints were applied to simulate thermal restraints from adjoining cool structures onto a heated composite column in a compartment. These real-sized 3.54 m long columns were subjected to concentric axial force at a load ratio of 0.7 at normal ambient temperature. Different degrees of axial restraint are investigated. An electric furnace was used to apply four-face heating condition on the columns for approximating a realistic fire scenario. All columns failed in flexural buckling mode. In the later part of the paper, finite element simulations were conducted to compare with test results. Numerical predictions of both temperature distribution and structural response during heating agree reasonably well with experimental data. Both test results and numerical analyses show that axial restraint significantly reduces the column fire resistance. Moreover, it was also observed that during heating all specimens underwent concrete spalling at mid-height, which noticeably decreased the fire resistance. Column critical times are also predicted according to Eurocode 4 Part 1.2, which are consistently shorter than the numerical predictions. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 50 条
  • [1] Fire resistance of composite columns with embedded I-section steel - Effects of section size and load level
    Huang, Zhan-Fei
    Tana, Kang-Hai
    Toh, Wee-Siang
    Phng, Guan-Hwee
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (03) : 312 - 325
  • [2] Testing of stainless steel I-section columns in fire
    Xing, Zhe
    Zhao, Ou
    Kucukler, Merih
    Gardner, Leroy
    ENGINEERING STRUCTURES, 2021, 227 (227)
  • [3] Behaviour and design of stainless steel I-section columns in fire
    Kucukler, Merih
    Xing, Zhe
    Gardner, Leroy
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 165 (165)
  • [4] FLEXURAL BUCKLING OF STAINLESS STEEL I-SECTION COLUMNS IN FIRE
    Kucukler, Merih
    Xing, Zhe
    Gardner, Leroy
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1569 - 1580
  • [5] Experimental study on axial compressive behavior of steel-bamboo I-section composite columns
    Zhang J.
    Mao M.
    Yu B.
    Wang J.
    Li Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (02): : 105 - 115
  • [6] Fire testing of austenitic stainless steel I-section beam-columns
    Xing, Zhe
    Zhao, Ou
    Kucukler, Merih
    Gardner, Leroy
    THIN-WALLED STRUCTURES, 2021, 164
  • [7] Effect of axial restraint on the performance of Elliptical Hollow Section steel columns, in hydrocarbon fire
    Scullion, Tom
    Ali, Faris
    Nadjai, Ali
    ENGINEERING STRUCTURES, 2011, 33 (12) : 3155 - 3161
  • [8] Fire resistance of axial restraint composite floor steel cellular beams
    Nadjai, Ali
    Han, Sanghoon
    Ali, Faris
    Alam, Naveed
    Allam, Ahmed
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 136 : 229 - 237
  • [9] Stainless steel I-section columns fire design considering the influence of loading history
    Rajic, Nikola
    Raseta, Andrija
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 198
  • [10] Evaluation of the Influence of Axial Loading on the Lateral Buckling Resistance of Tapered Laminated Composite I-Section Beam-Columns
    Abolghasemian, R.
    Soltani, M.
    Ghasemi, A. R.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2024, 48 (02) : 779 - 797