Does Heparin Coating Improve Patency or Reduce Infection of Tunneled Dialysis Catheters?

被引:48
|
作者
Jain, Gaurav [1 ]
Allon, Michael [1 ]
Saddekni, Souheil [2 ]
Barker-Finkel, Jill [3 ]
Maya, Ivan D. [1 ]
机构
[1] Univ Alabama, Intervent Nephrol Sect, Div Nephrol, Birmingham, AL 35294 USA
[2] Univ Alabama, Div Intervent Radiol, Birmingham, AL 35294 USA
[3] Montana State Univ, Dept Microbiol, Bozeman, MT 59717 USA
关键词
OUTCOMES; ACCESS; TRIAL;
D O I
10.2215/CJN.03920609
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: Tunneled dialysis catheters are prone to frequent malfunction and infection. Catheter thrombosis occurs despite prophylactic anticoagulant locks. Catheter thrombi may also serve as a nidus for catheter infection, thereby increasing the risk of bacteremia. Thus, heparin coating of catheters may reduce thrombosis and infection. This study evaluated whether heparin-coated hemodialysis catheters have fewer infections or greater cumulative survival than noncoated catheters. Design, setting, participants, & measurements: We retrospectively queried a prospective access database to analyze the outcomes of 175 tunneled dialysis catheters placed in the internal jugular vein, including 89 heparin-coated catheters and 86 noncoated catheters. The primary outcome was cumulative catheter survival, and the secondary outcome was infection-free catheter survival. Results: The two patient groups were similar in demographics and clinical and catheter features. Catheter-related bacteremia occurred less frequently with heparin-coated catheters than with noncoated catheters (34 versus 60%, P < 0.001). Cumulative catheter survival was similar in heparin-coated and noncoated catheters (hazard ratio, 0.87; 95% confidence interval, 0.55 to 1.36; P = 0.53). On multiple variable survival analysis including catheter type, age, sex, diabetes, coronary artery disease, peripheral vascular disease, cerebrovascular disease, catheter location, and previous catheter, only catheter location predicted cumulative catheter survival (hazard ratio, 2.03; 95% Cl, 1.27 to 3.25, with the right internal jugular location being the reference group, P = 0.003). The frequency of thrombolytic instillation was 1.8 per 1000 catheter-days in both groups. Conclusions: Heparin coating decreases the frequency of catheter-related bacteremia but does not reduce the frequency of catheter malfunction. Clin J Am Soc Nephrol 4: 1787-1790, 2009. doi: 10.2215/CJN.03920609
引用
收藏
页码:1787 / 1790
页数:4
相关论文
共 36 条
  • [1] Silver coating of dialysis catheters to reduce bacterial colonization and infection
    Tobin, EJ
    Bambauer, R
    THERAPEUTIC APHERESIS AND DIALYSIS, 2003, 7 (06): : 504 - 509
  • [2] Heparin Bonding Does Not Improve Patency of Polytetrafluoroethylene Arteriovenous Grafts
    Allemang, Matthew T.
    Schmotzer, Brian
    Wong, Virginia L.
    Chang, Alexander
    Lakin, Ryan O.
    Woodside, Kenneth J.
    Wang, John
    Kashyap, Vikram S.
    ANNALS OF VASCULAR SURGERY, 2014, 28 (01) : 28 - 34
  • [3] Infectious Recidivism in Tunneled Dialysis Catheters Removed for Bloodstream Infection in the Intensive Care Unit
    Hung, Matthew L.
    DePietro, Daniel M.
    Trerotola, Scott O.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 32 (05) : 650 - 655
  • [4] RANDOMIZED, PROSPECTVE STUDY OF ZURAGEN™ VERSUS HEPARIN AS LOCKS FOR TUNNELED CENTRAL VENOUS CATHETERS FOR DIALYSIS (CVCD)
    Ash, S. R.
    Steczko, J.
    Winger, R.
    Brewer, L.
    Lavin, P.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (07): : 402 - 402
  • [5] Randomized study of silver coating (Silvergard) for prevention of infection in tunneled hemodialysis catheters.
    Trerotola, SO
    Kraus, M
    Johnson, MS
    Harris, VJ
    Snidow, JJ
    Shah, H
    McKusky, M
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0878 - A0878
  • [6] DOES CONTINUOUS HEPARIN INFUSION REDUCE OCCLUSION OF UMBILICAL ARTERY CATHETERS
    BOSQUE, E
    WEAVER, L
    CLINICAL RESEARCH, 1985, 33 (01): : A135 - A135
  • [7] A New Method for the Measurement of International Normalized Ratio in Hemodialysis Patients with Heparin-Locked Tunneled Dialysis Catheters
    Seghers, Celine B.
    Ver Elst, Kristien
    Claessens, Jolien
    Weekx, Steven
    Vermeiren, Sigrid
    Henckes, Manu
    INTERNATIONAL JOURNAL OF NEPHROLOGY, 2020, 2020
  • [8] A NEW METHOD FOR THE MEASUREMENT OF INTERNATIONAL NORMALIZED RATIO IN HEMODIALYSIS PATIENTS WITH HEPARIN-LOCKED TUNNELED DIALYSIS CATHETERS
    Seghers, Celine B.
    Ver Elst, Kristien
    Claessens, Jolien
    Henckes, Manu
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34
  • [9] Randomized study of silver coating (Silvergard) for prevention of infection in tunneled hemodialysis catheters: Final report
    Trerotola, SO
    Johnson, MS
    Shah, H
    Kraus, M
    McKusky, M
    Ambrosius, WT
    RADIOLOGY, 1997, 205 : 639 - 639
  • [10] THROMBOGENICITY OF UMBILICAL ARTERY CATHETERS - DOES BONDING HEPARIN TO POLYURETHANE REDUCE COMPLICATIONS
    JACKSON, JC
    TRUOG, WE
    WATCHKO, JF
    MACK, LA
    PEDIATRIC RESEARCH, 1986, 20 (04) : A350 - A350