Monitoring of side shift exercise using an electromagnetic three-dimensional measuring device

被引:0
|
作者
Maruyama, T [1 ]
Takahashi, M [1 ]
Mochizuki, K [1 ]
Nakamura, K [1 ]
机构
[1] Teikyo Univ, Sch Med, Dept Orthopaed Surg, Itabashi Ku, Tokyo 1738605, Japan
来源
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In order to investigate the usefulness of an electromagnetic three-dimensional measuring device as a monitor for the side shift exercise, the evaluation by the well-trained physical therapist as to whether the exercise was properly performed or not was compared with the evaluation using data obtained by the device. The side shift exercises performed by twenty-four female patients with idiopathic scoliosis were classified as "good," "rotation," or "bend" by the well-trained physical therapist. By the use of the data obtained by the electromagnetic three-dimensional measuring device, whether the exercise was "rotation" or not could be predicted with 100% sensitivity and 100% specificity, and whether the exercise was "bend" or not could be predicted with 83% sensitivity and 100% specificity. These results suggested that the electromagnetic three-dimensional measuring device could be a useful monitor for the side shift exercise.
引用
收藏
页码:212 / 214
页数:3
相关论文
共 50 条
  • [31] Measuring Crack Porosity using Three-Dimensional Electrical Resistivity Tomography
    Ackerson, Jason P.
    McInnes, Kevin J.
    Morgan, Cristine L. S.
    Everett, Mark E.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2017, 81 (05) : 1025 - 1035
  • [32] Measuring the Three-Dimensional Morphology of Crystals Using Regular Reflection of Light
    Chakraborty, Jayanta
    Sarkar, Debasis
    Singh, Abhishek
    Bharti, Aman Kumar
    CRYSTAL GROWTH & DESIGN, 2012, 12 (12) : 6042 - 6049
  • [33] Flexible Electromagnetic Cap for Three-Dimensional Electromagnetic Head Imaging
    Alqadami, Abdulrahman S. M.
    Zamani, Ali
    Trakic, Adnan
    Abbosh, Amin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (09) : 2880 - 2891
  • [34] Three-dimensional axisymmetric flow-focusing device using stereolithography
    Yuya Morimoto
    Wei-Heong Tan
    Shoji Takeuchi
    Biomedical Microdevices, 2009, 11 : 369 - 377
  • [35] Three-dimensional GIS moves to the transmission side
    Anon
    Electrical World, 2001, 215 (02):
  • [36] Three-dimensional axisymmetric flow-focusing device using stereolithography
    Morimoto, Yuya
    Tan, Wei-Heong
    Takeuchi, Shoji
    BIOMEDICAL MICRODEVICES, 2009, 11 (02) : 369 - 377
  • [37] Side branching in the three-dimensional dendritic growth
    Brener, E.A.
    Temkin, D.E.
    JETP Letters (Translation of JETP Pis'ma v Redaktsiyu), 1994, 59 (10):
  • [38] Three-dimensional dose reconstruction using an electronic portal imaging device
    Hagness, C
    Herman, M
    MEDICAL PHYSICS, 2003, 30 (06) : 1345 - 1345
  • [39] A three-dimensional scheme for singlewell electromagnetic inversion
    Lazarev, YN
    Newman, GA
    Petrov, PV
    SUBSURFACE AND SURFACE SENSING TECHNOLOGIES AND APPLICATIONS III, 2001, 4491 : 193 - 202
  • [40] Three-dimensional electromagnetic wave polarizations in a plasma
    Dong, B
    Yeh, KC
    RADIO SCIENCE, 2002, 37 (06)