The Electromagnetic Calorimeter trigger system for the AMS-2 experiment

被引:0
|
作者
Adloff, C. [1 ]
Cadoux, F. [1 ]
Chen, G. M. [1 ]
Chen, H. S. [1 ]
Cervelli, F. [1 ]
Coignet, G. [1 ]
Cougolat, G. [1 ]
Di Falco, St. [1 ]
Caleotti, St. [1 ]
Goy, C. [1 ]
Hermel, R. [1 ]
Kossakowski, R. [1 ]
Incagli, M. [1 ]
Li, Z. H. [1 ]
Lu, Y. S. [1 ]
Magazzu, C. [1 ]
Pedreschi, E. [1 ]
Piendibene, M. [1 ]
Pilo, F. [1 ]
Pochon, J. [1 ]
Rosier-Lees, S. [1 ]
Spinella, F. [1 ]
Tang, X. W. [1 ]
Vannini, C. [1 ]
Vialle, J. P. [1 ]
Yang, C. G. [1 ]
Yang, M. [1 ]
Yu, Z. Q. [1 ]
Zhuang, H. L. [1 ]
机构
[1] LAPP, Lab Annecy Le Vieux Phys Particules, F-74941 Annecy Le Vieux, France
来源
2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2005年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
AMS-02 is an astroparticle experiment designed for a very precise measurement of primary cosmic rays spectrum. The experiment will operate on board of the ISS at a 400 km altitude for a period of about 3 years. The main scientific goals of the experiment are the search for antimatter, for dark matter and the study of gamma rays. In AXIS the Electromagnetic Calorimeter plays a key role for its high capability to measure e(+), e(-) and gamma spectra and to suppress the background generated by p and He nuclei. To directly detect photons the calorimeter is requested to provide a stand alone trigger. The proposed trigger, presented in this article, will have the capability to detect photons with energy above 4 GeV with an efficiency of about 100%. The hardware implementation foresees an analog section, comparing the photomultiplier signal with a given threshold, and a digital section applying the trigger selection algorithm.
引用
收藏
页码:274 / 277
页数:4
相关论文
共 50 条
  • [1] The Electromagnetic Calorimeter trigger system for the AMS-02 experiment
    Cadoux, F.
    Cervelli, F.
    Coignet, G.
    Cougolat, G.
    Di Falco, S.
    Goy, C.
    Hermel, R.
    Kossakowski, R.
    Incagli, M.
    Li, Z. H.
    Lu, Y. S.
    Magazzu, C.
    Pedreschi, E.
    Piendibene, M.
    Pilo, F.
    Pochon, J.
    Rosier-Lees, S.
    Spinella, Franco
    Vannini, C.
    Vialle, J. P.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (02) : 817 - 821
  • [2] The Transition Radiation Detector of the AMS-2 experiment
    Schwering, G
    Fopp, S
    Karpinski, W
    Kirn, T
    Lübelsmeyer, K
    Orboeck, J
    Schael, S
    Dratzig, ASV
    Siedenburg, T
    Sielding, R
    Wallraff, W
    Becker, U
    Burger, J
    Capell, M
    Corosi, GP
    Demirkoz, B
    Fisher, P
    Henning, R
    Koutsenko, V
    Kunin, A
    Monreal, B
    Scholberg, K
    ADVANCED TECHNOLOGY AND PARTICLE PHYSICS, PROCEEDINGS, 2002, 1 : 57 - 61
  • [3] Design of a Electromagnetic Calorimeter Trigger System for the Belle II Experiment
    Cheon, Byung Gu
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 57 (06) : 1369 - 1375
  • [4] Status of the Electromagnetic Calorimeter Trigger system at the Belle II experiment
    Kim, S. H.
    Lee, I. S.
    Unno, Y.
    Cheon, B. G.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [5] A Digital Trigger for the Electromagnetic Calorimeter at the COMPASS Experiment
    Huber, Stefan
    Friedrich, Jan
    Ketzer, Bernhard
    Konorov, Igor
    Kraemer, Markus
    Mann, Alexander
    Nagel, Thiemo
    Paul, Stephan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (04) : 1719 - 1722
  • [6] The level-1 trigger system for the electromagnetic calorimeter of the COMET experiment
    Epshteyn, L. B.
    Akhmetshin, R. R.
    Grigogiev, D. N.
    Kazanin, V. F.
    Melnik, A. S.
    Shoukovy, Dz. V.
    Yudin, Yu. V.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [7] A study of the electromagnetic calorimeter trigger signal for the BELLE experiment
    Ikeda, H.
    Cheon, B. G.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 50 (05) : 1224 - 1228
  • [8] Progress on the Electromagnetic Calorimeter Trigger Simulation at the Belle II Experiment
    Lee, I. S.
    Kim, S. H.
    Kim, C. H.
    Cho, H. E.
    Kim, Y. J.
    Ahn, J. K.
    Jang, E. J.
    Choi, S. -K.
    Iwasaki, Y.
    Kuzmin, A.
    Unno, Y.
    Cheon, B. G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (09) : 2143 - 2147
  • [9] A Trigger less readout system for the PANDA electromagnetic calorimeter
    Tiemens, M.
    16TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2014), 2015, 587
  • [10] Status of the electromagnetic calorimeter trigger system at Belle II
    Kim, SungHyun
    Lee, InSoo
    Unno, Yuuji
    Cheon, ByungGu
    17TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2016), 2017, 928