A biosensor based on fungal soil biomass for electrochemical detection of lead (II) and cadmium (II) by differential pulse anodic stripping voltammetry

被引:53
|
作者
Dali, Mounira [1 ]
Zinoubi, Khaoula [2 ]
Chrouda, Amani [2 ]
Abderrahmane, Sihem [1 ]
Cherrad, Semcheddine [3 ]
Jaffrezic-Renault, N. [4 ]
机构
[1] Badji Mokhtar Univ, Fac Sci, Lab Surface Engn, POB 12, Annaba 23000, Algeria
[2] Univ Monastir, Fac Sci, Lab Interfaces & Adv Mat, Monastir, Tunisia
[3] Univ Lyon 1, Pathogenesis Mushrooms Necro Trophies Team, UMR Lab 5240, Bayer Crop Sci,CNRS, F-69263 Lyon, France
[4] Lab Analyt Sci, F-69100 Lyon, France
关键词
Fungal soil biomass; Single walled carbon nanotubes (SWCNTs); Chemically modified CGE; DPASV; Heavy metals biosensor; HEAVY-METAL CONTAMINATION; GRAPHENE QUANTUM DOTS; CARBON NANOTUBES; CELL-WALL; FILM ELECTRODE; BIOSORPTION; SPECTROSCOPY; SENSOR; OXIDE; IONS;
D O I
10.1016/j.jelechem.2018.02.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive voltammetric method for detection of trace heavy metal ions using a glassy carbon electrode surfaces chemically modified by a mixture of (SWCNTs/Biomass) was applied. The fungus is used as an inactive biomass, which was selected from soil contaminated with metals. The cell walls have a large number of chemical groups such as carboxyl, sulfonate, amine, hydroxyl, carbonyl and imidazole with which may affect and intervene in the fixing of metal ions. In this assay, heavy metals ions accumulated on the GCE/SWCNTs/Biomass electrode surfaces prior to being subjected to differential pulse anodic stripping voltammetry analysis (DPASV). The resulting peak currents were linearly related to the concentrations of the metal ions. The method was optimized with respect to accumulation time, reduction time and reduction potential. The detection limits were found to be 10(-8)M and 10(-7)M for Pb2+ and Cd2+ respectively.
引用
收藏
页码:9 / 19
页数:11
相关论文
共 50 条
  • [1] An electrochemical sensor based on green tea extract for detection of Cd(II) ions by differential pulse anodic stripping voltammetry
    Incebay, Hilal
    Aktepe, Leyla
    Leblebici, Zeliha
    [J]. SURFACES AND INTERFACES, 2020, 21
  • [2] Determination of lead and cadmium in titanium dioxide by differential pulse anodic stripping voltammetry
    Panigati, M
    Piccone, M
    D'Alfonso, G
    Orioli, M
    Carini, M
    [J]. TALANTA, 2002, 58 (03) : 481 - 488
  • [3] DETERMINATION OF MERCURY(II) BY "DIFFERENTIAL-PULSE-ANODIC-STRIPPING VOLTAMMETRY
    SONTAG, G
    KERSCHBAUMER, M
    KAINZ, G
    [J]. MIKROCHIMICA ACTA, 1976, 2 (3-4) : 411 - 422
  • [4] DETERMINATION OF CADMIUM, LEAD AND COPPER IN WINE BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    OEHME, M
    LUND, W
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1979, 294 (05): : 391 - 397
  • [5] DETERMINATION OF CADMIUM, LEAD AND COPPER IN URINE BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    LUND, W
    ERIKSEN, R
    [J]. ANALYTICA CHIMICA ACTA, 1979, 107 (JUN) : 37 - 46
  • [6] Determination of bioavailable species of lead and cadmium in soils by differential pulse anodic stripping voltammetry
    Kudravá, M
    Rúriková, D
    [J]. CHEMICKE LISTY, 2005, 99 (10): : 731 - 736
  • [7] DETERMINATION OF LEAD AND CADMIUM IN URINE BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    ONAR, AN
    TEMIZER, A
    [J]. ANALYST, 1987, 112 (03) : 227 - 229
  • [8] Forms of binding of copper, lead, and cadmium in carbonate type soil studied by differential pulse anodic stripping voltammetry
    Kozakova, E
    Spankova, M
    Kandrac, J
    Mikus, P
    [J]. CHEMICAL PAPERS-CHEMICKE ZVESTI, 1996, 50 (06): : 334 - 340
  • [9] On-line detection of Cu (II) in bioleaching system by anodic stripping differential pulse voltammetry
    Jin, Yan
    Chen, Miao
    Jin, Qing-hui
    Zhao, Jian-long
    [J]. TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2014, 24 (02) : 582 - 587
  • [10] Investigation of Copper(II) Interference on the Anodic Stripping Voltammetry of Lead(II) and Cadmium(II) at Bismuth Film Electrode
    Yang, Die
    Wang, Liang
    Chen, Zuliang
    Megharaj, Mallavarapu
    Naidu, Ravi
    [J]. ELECTROANALYSIS, 2013, 25 (12) : 2637 - 2644