Monitoring of breathing motion in image-guided PBS proton therapy: comparative analysis of optical and electromagnetic technologies

被引:22
|
作者
Fattori, Giovanni [1 ]
Safai, Sairos [1 ]
Carmona, Pablo Fernandez [1 ]
Peroni, Marta [1 ]
Perrin, Rosalind [1 ]
Weber, Damien Charles [1 ,2 ]
Lomax, Antony John [1 ,3 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, CH-5232 Villigen, Switzerland
[2] Inselspital Univ tsspital Bern, Dept Radiat Oncol, CH-3010 Bern, Switzerland
[3] ETH Honggerberg, Dept Phys, CH-8093 Zurich, Switzerland
来源
RADIATION ONCOLOGY | 2017年 / 12卷
关键词
Respiratory motion; Optical tracking; Electromagnetic tracking; Proton therapy; Gantry; CT imaging; TIME TUMOR TRACKING; FIDUCIAL MARKERS; TREATMENT DELIVERY; SYSTEM; RADIOTHERAPY; CANCER; LUNG; ACCURACY; PROSTATE; ENVIRONMENT;
D O I
10.1186/s13014-017-0797-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Motion monitoring is essential when treating non-static tumours with pencil beam scanned protons. 4D medical imaging typically relies on the detected body surface displacement, considered as a surrogate of the patient's anatomical changes, a concept similarly applied by most motion mitigation techniques. In this study, we investigate benefits and pitfalls of optical and electromagnetic tracking, key technologies for non-invasive surface motion monitoring, in the specific environment of image-guided, gantry-based proton therapy. Methods: Polaris SPECTRA optical tracking system and the Aurora V3 electromagnetic tracking system from Northern Digital Inc. (NDI, Waterloo, CA) have been compared both technically, by measuring tracking errors and system latencies under laboratory conditions, and clinically, by assessing their practicalities and sensitivities when used with imaging devices and PBS treatment gantries. Additionally, we investigated the impact of using different surrogate signals, from different systems, on the reconstructed 4D CT images. Results: Even though in controlled laboratory conditions both technologies allow for the localization of static fiducials with sub-millimetre jitter and low latency (31.6 +/- 1 msec worst case), significant dynamic and environmental distortions limit the potential of the electromagnetic approach in a clinical setting. The measurement error in case of close proximity to a CT scanner is up to 10.5 mm and precludes its use for the monitoring of respiratory motion during 4DCT acquisitions. Similarly, the motion of the treatment gantry distorts up to 22 mm the tracking result. Conclusions: Despite the line of sight requirement, the optical solution offers the best potential, being the most robust against environmental factors and providing the highest spatial accuracy. The significant difference in the temporal location of the reconstructed phase points is used to speculate on the need to apply the same monitoring system for imaging and treatment to ensure the consistency of detected phases.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Monitoring of breathing motion in image-guided PBS proton therapy: comparative analysis of optical and electromagnetic technologies
    Giovanni Fattori
    Sairos Safai
    Pablo Fernández Carmona
    Marta Peroni
    Rosalind Perrin
    Damien Charles Weber
    Antony John Lomax
    [J]. Radiation Oncology, 12
  • [2] Advanced technologies in image-guided radiation therapy
    Balter, James M.
    Cao, Yue
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2007, 17 (04) : 293 - 297
  • [3] Image-Guided Proton Therapy: A Comprehensive Review
    Lane, Shelby A.
    Slater, Jason M.
    Yang, Gary Y.
    [J]. CANCERS, 2023, 15 (09)
  • [4] Optical Image-Guided Cancer Therapy
    Bu, Lihong
    Ma, Xiaowei
    Tu, Yingfeng
    Shen, Baozhong
    Cheng, Zhen
    [J]. CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2013, 14 (08) : 723 - 732
  • [5] The implementation of an image-guided system at a proton therapy center facility
    Arjomandy, Bijan
    Buele, Ana Isabel Bejarano
    Clinthorne, Neal
    Vujasevic, Milos
    Athar, Basit
    Deemer, James
    Alkhatib, Ahmad
    Hussain, Abrar
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (03):
  • [6] The role of image-guided intensity modulated proton therapy in glioma
    Grosshans, David R.
    Mohan, Radhe
    Gondi, Vinai
    Shih, Helen A.
    Mahajan, Anita
    Brown, Paul D.
    [J]. NEURO-ONCOLOGY, 2017, 19 : 30 - 37
  • [7] Biological lung phantom for image-guided proton therapy validation
    Folkert, M. R.
    Chen, G. T. Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S496 - S496
  • [8] Shifting Focus in Optical Image-Guided Cancer Therapy
    Stijn Keereweer
    Pieter B. A. A. Van Driel
    Dominic J. Robinson
    Clemens W. G. M. Lowik
    [J]. Molecular Imaging and Biology, 2014, 16 : 1 - 9
  • [9] Shifting Focus in Optical Image-Guided Cancer Therapy
    Keereweer, Stijn
    Van Driel, Pieter B. A. A.
    Robinson, Dominic J.
    Lowik, Clemens W. G. M.
    [J]. MOLECULAR IMAGING AND BIOLOGY, 2014, 16 (01) : 1 - 9
  • [10] A pencil beam algorithm for magnetic resonance image-guided proton therapy
    Padilla-Cabal, Fatima
    Georg, Dietmar
    Fuchs, Hermann