Predictors of permanent pacemaker implantation after ACURATE neo transcatheter heart valve implantation

被引:15
|
作者
Kim, Won-Keun [1 ,2 ]
Moellmann, Helge [3 ]
Walther, Thomas [4 ]
Hamm, Christian W. [1 ,2 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiol, Campus Univ Giessen, Bad Nauheim, Germany
[2] Justus Liebig Univ Giessen, Dept Cardiol, Giessen, Germany
[3] St Johannes Hosp, Dept Cardiol, Dortmund, Germany
[4] Goethe Univ Frankfurt, Dept Cardiac Surg, Frankfurt, Germany
来源
关键词
aortic stenosis; pacemaker implantation; self‐ expanding; TAVI; THV;
D O I
10.1111/pace.14155
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Rates of permanent pacemaker implantation (PPI) have been low using the self-expanding ACURATE neo device, but data regarding risk factors of PPI for this specific device are scarce. Methods The study cohort consisted of patients (n = 1000) with severe aortic stenosis undergoing transfemoral transcatheter aortic valve implantation (TAVI) using the ACURATE neo prosthesis in our center between May 2012 and December 2019. For the present analysis, we excluded patients with previous permanent pacemaker (n = 110), high-grade AV block prior to TAVI (n = 3), and patients requiring conversion to surgical valve replacement (n = 4) or the implantation of a second prosthesis as valve-in-valve (n = 15). Preexisting conduction abnormalities were determined, and the implantation depth of the prosthesis was measured on final angiography. Differences across quartiles based on the original consecutive cohort were analyzed with respect to implantation depth and PPI rate. Predictors of PPI were identified using logistic regression. Results The PPI rate was 10%. Preexisting AV block I degrees, right bundle branch block (RBBB), and the implantation depth were independent predictors of PPI. Across quartiles, the implantation depth differed significantly with lowest values in the last quartile, whereas differences of PPI rates across quartiles were not statistically significant, but showed a notable decrease in the last quartile. Conclusion Preexisting RBBB, AV block I degrees, and low implantation depth were independent predictors of PPI following TAVI using the ACURATE neo device. Instead of deliberately aiming at a high position, avoidance of a low implantation depth may represent a reasonable compromise to reduce the rate of PPI without increasing the risk of malpositioning.
引用
收藏
页码:410 / 415
页数:6
相关论文
共 50 条
  • [1] Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation
    Fateh-Moghadam, Suzanne
    Pachlhofer, Amelie
    Steeg, Martin
    Mueller, Iris
    Doernberger, Volker
    Doernberger, Volker
    Gawaz, Meinrad
    Bocksch, Wolfgang
    [J]. CIRCULATION, 2014, 130
  • [2] Very low pacemaker rate following ACURATE neo transcatheter heart valve implantation
    Toggweiler, Stefan
    Nissen, Henrik
    Mogensen, Brynjolfur
    Cuculi, Florim
    Fallesen, Christian
    Veien, Karsten Tange
    Brinkert, Miriam
    Kobza, Richard
    Ruck, Andreas
    [J]. EUROINTERVENTION, 2017, 13 (11) : 1274 - 1281
  • [3] Paravalvular Leak After Implantation of the ACURATE neo and the ACURATE neo2 Transcatheter Heart Valve
    Toggweiler, Stefan
    Brinkert, Miriam
    Wolfrum, Mathias
    Moccetti, Federico
    Stampfli, Simon F.
    De Boeck, Bart W. L.
    Magarzo, Getulio
    Gassenmaier, Tobias
    Attinger-Toller, Adrian
    Bossard, Matthias
    Fornaro, Jurgen
    Buhmann, Ralf
    Cuculi, Florim
    Kobza, Richard
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 45 : 37 - 43
  • [4] Hypoattenuated Leaflet Thickening After Implantation of the ACURATE neo or the ACURATE neo2 Transcatheter Heart Valve
    Brunner, Stephanie
    Brinkert, Miriam
    Moccetti, Federico
    Loretz, Lucca
    Fornaro, Jurgen
    Stampfli, Simon F.
    Attinger-Toller, Adrian
    Bossard, Matthias
    Buhmann, Ralf
    Cuculi, Florim
    Wolfrum, Mathias
    Toggweiler, Stefan
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2023, 200 : 146 - 152
  • [5] Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with the CoreValve prosthesis
    Hausen, S.
    Sinning, J. M.
    Werner, N.
    Nickenig, G.
    Grube, E.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 578 - 578
  • [6] Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve implantation
    Chen, Bing-Ying
    Huang, Ting-Feng
    Jiang, Xin-Da
    Ding, Xiao-Yan
    Zhou, Xiao-Fen
    [J]. BMC CARDIOVASCULAR DISORDERS, 2024, 24 (01):
  • [7] Predictors of permanent pacemaker implantation after transcatheter corevalve implantation
    Giannini, C.
    De Carlo, M.
    Bedogni, F.
    Klugmann, S.
    Brambilla, N.
    De Marco, F.
    Zucchelli, G.
    Testa, L.
    Oreglia, J.
    Petronio, A. S.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 481 - 481
  • [8] Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Hoyt, Matthew J.
    Hathaway, Jessica
    Palmer, Roseanne
    Beach, Michael
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (05) : 1162 - 1166
  • [9] Rate and Predictors of Permanent Pacemaker Implantation after Transcatheter Aortic Valve Implantation: Current Status
    Russo, Elconora
    Potenza, Domenico R.
    Casclla, Michela
    Massaro, Raimondo
    Russo, Giulio
    Braccio, Maurizio
    Dello Russo, Antonio
    Cassese, Mauro
    [J]. CURRENT CARDIOLOGY REVIEWS, 2019, 15 (03) : 205 - 218
  • [10] Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with the Medtronic CoreValve system
    Fateh-Moghadam, S.
    Pachelhofer, A.
    Steeg, M.
    Doernberger, V.
    Gawaz, M.
    Bocksch, W.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 412 - 412