Transtibial amputee joint rotation moments during straight-line walking and a common turning task with and without a torsion adapter

被引:22
|
作者
Segal, Ava D. [1 ,2 ]
Orendurff, Michael S. [1 ]
Czerniecki, Joseph M. [1 ,3 ]
Shofer, Jane B. [1 ]
Klute, Glenn K. [1 ,2 ,4 ]
机构
[1] Puget Sound Hlth Care Syst, Dept Vet Affairs, Rehabil Res & Dev Serv, Ctr Excellence Limb Loss Prevent & Prosthet Engn, Seattle, WA 98108 USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Rehabil Med, Seattle, WA 98195 USA
[4] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
来源
关键词
amputee; kinetics; moment; prosthesis; rehabilitation; rotation; torque; torsion adapter; transtibial; transverse plane; turning; GAIT; ADULTS; OLDER;
D O I
10.1682/JRRD.2008.06.0070
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Amputees lack movement and control mechanisms at the foot and ankle that result in different strategies for locomotion than nonamputees. The torsion adapter is a prosthetic device designed to minimize shear stress at the residual limb by facilitating rotation in the transverse plane. This study determined if the addition of a torsion adapter alters lower-limb joint rotation moments of transtibial amputees walking in a straight line and turning. Ten transtibial amputees wore either a torsion adapter or a rigid adapter for an acclimation period of 3 weeks in random order. Ten nonamputees were also included for comparison. Kinetics were collected as participants walked in a straight line and around a 1 m-radius circular path at their self-selected turning walking speed. When amputee participants wore the torsion adapter, they demonstrated decreased prosthetic-limb peak internal rotation moments at the inside limb knee and hip compared with when they wore the rigid adapter, which may facilitate changes in orientation by not actively resisting the turn. Nonamputees exhibited larger moments compared with the prosthetic limb for both the amputee participants wearing either the torsion or rigid adapters. No differences were found in the moments for the intact limb between torsion and rigid adapter conditions during turning and for both limbs during straight-line walking.
引用
收藏
页码:375 / 383
页数:9
相关论文
共 3 条
  • [1] Comparison of transtibial amputee and non-amputee biomechanics during a common turning task
    Segal, Ava D.
    Orendurff, Michael S.
    Czerniecki, Joseph M.
    Schoen, Jason
    Klute, Glenn K.
    GAIT & POSTURE, 2011, 33 (01) : 41 - 47
  • [2] Local dynamic stability of amputees wearing a torsion adapter compared to a rigid adapter during straight-line and turning gait
    Segal, Ava D.
    Orendurff, Michael S.
    Czerniecki, Joseph M.
    Shofer, Jane B.
    Klute, Glenn K.
    JOURNAL OF BIOMECHANICS, 2010, 43 (14) : 2798 - 2803
  • [3] Gait events during turning can be detected using kinematic features originally proposed for the analysis of straight-line walking
    Ulrich, Baptiste
    Santos, Alejandro N.
    Jolles, Brigitte M.
    Benninger, David H.
    Favre, Julien
    JOURNAL OF BIOMECHANICS, 2019, 91 : 69 - 78