摘要
Previously we presented a morphologic concentric layered (MCL) algorithm for the detection of masses in screening mammograms. The algorithm achieved high sensitivity (92%) but it also generated 3.26 false positives (FPs) per image. In the present study we propose a false positive reduction strategy based on using an artificial neural network that merges feature and knowledge-based analysis of suspicious mammographic locations. The ANN integrates two types of information regarding the suspicious candidates: (i) directional and fractal neighborhood analysis features, and (ii) knowledge-based analysis using an information-theoretic similarity metric. The study hypothesis is that the synergistic application of feature and knowledge-based analysis will be an effective strategy to reduce false positives while still maintaining sufficiently the detection rate for true masses. The study was performed using mammograms from the Digital Database of Screening Mammography. Using the fusion ANN decision strategy 56% of the FPs were reduced while maintaining 95% of the true masses.
引用
收藏
页码:6524 / 6527
页数:4
相关论文
共 50 条
  • [1] Adaptive feature analysis of false positives for computerized detection of lung nodules in digital chest images
    Xu, XW
    MacMahon, H
    Giger, ML
    Doi, K
    [J]. IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 : 428 - 436
  • [2] Computerized detection of pulmonary nodules in chest radiographs: Reduction of false positives based on radiologists' visual analysis strategy
    Yoshida, H
    Li, L
    Doi, K
    MacMahon, H
    [J]. RADIOLOGY, 2000, 217 : 548 - 548
  • [3] Reduction of false positives in the screening CAD tool for microcalcification detection
    Karale, Vikrant A.
    Singh, Tulika
    Sadhu, Anup
    Khandelwal, Niranjan
    Mukhopadhyay, Sudipta
    [J]. SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2020, 45 (01):
  • [4] Reduction of false positives in the screening CAD tool for microcalcification detection
    Vikrant A Karale
    Tulika Singh
    Anup Sadhu
    Niranjan Khandelwal
    Sudipta Mukhopadhyay
    [J]. Sādhanā, 2020, 45
  • [5] Reduction of false positives in computerized detection of pulmonary nodules in chest radiographs based on local contralateral comparison of lungs
    Yoshida, H
    Lan, L
    Doi, K
    MacMahon, H
    [J]. CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 809 - 813
  • [6] Local contralateral subtraction based on bilateral symmetry of lung for reduction of false positives in computerized detection of pulmonary nodules
    Yoshida, H
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (05) : 778 - 789
  • [7] ON THE REDUCTION OF FALSE POSITIVES IN SINGING VOICE DETECTION
    Lehner, Bernhard
    Widmer, Gerhard
    Sonnleitner, Reinhard
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2014,
  • [8] Computerized detection of pulmonary nodules in chest radiographs: reduction of false positives based on symmetry between left and right lungs
    Yoshida, H
    Doi, K
    [J]. MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 97 - 102
  • [9] Sources of false positives in computerized detection of polyps in CT colonography
    Dachman, AH
    Nappi, JJ
    Frimmel, H
    Yoshida, H
    [J]. RADIOLOGY, 2002, 225 : 303 - 304
  • [10] Computerized detection of unruptured aneurysms in MRA images: Reduction of false positives using anatomical location features
    Uchiyama, Yoshikazu
    Gao, Xin
    Hara, Takeshi
    Fujita, Hiroshi
    Ando, Hiromichi
    Yamakawa, Hiroyasu
    Asano, Takahiko
    Kato, Hiroki
    Iwama, Toru
    Kanematsu, Masayuki
    Hoshi, Hiroaki
    [J]. MEDICAL IMAGING 2008: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2008, 6915