An analysis of potential predictors of tunneled hemodialysis catheter infection or dysfunction

被引:15
|
作者
Coker, M. Austin [1 ]
Black, J. Ryne [1 ]
Li, Yufeng [2 ]
Varma, Rakesh [1 ]
Almehmi, Ammar [3 ]
Aal, Ahmed K. Abdel [1 ]
Gunn, Andrew J. [1 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, Div Vasc & Intervent Radiol, 619 19th St South,NHB 623, Birmingham, AL 35249 USA
[2] Univ Alabama Birmingham, Div Prevent Med, Birmingham, AL 35249 USA
[3] Univ Alabama Birmingham, Div Nephrol, Birmingham, AL 35249 USA
来源
JOURNAL OF VASCULAR ACCESS | 2019年 / 20卷 / 04期
关键词
Dialysis; tunneled catheter; complications; infection; BLOOD-STREAM INFECTIONS; RISK-FACTORS; VASCULAR ACCESS; MAINTENANCE; HEPARIN; DISEASE;
D O I
10.1177/1129729818809669
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: To assess the ability of various clinical factors to predict infection or dysfunction of tunneled hemodialysis catheters. Methods: A retrospective review of all adult patients who had a tunneled hemodialysis catheter placed between 2012 and 2016 was performed. Tunneled hemodialysis catheters were considered infected based on clinical suspicion or culture-positive bacteremia. Dysfunction was defined as all other non-infectious causes for line failure. Time-to-removal or exchange was recorded. Clinical parameters analyzed as potential predictors of tunneled hemodialysis catheter infection or dysfunction, included the following: age, sex, site of placement, inpatient versus outpatient status at time of placement, body mass index, Charlson Comorbidity Index, neutrophil-to-lymphocyte ratio, platelet-to-lymphocyte ratio, platelet count, white blood cell count, international normalized ratio, and partial thromboplastin time. Results: A total of 177 patients (95: female, 82: male; 71.7%: African American; mean age: 54.9 years) qualified for inclusion. The internal jugular vein was the site of placement in 97.1% of patients with 79.7% of lines being placed on the right side. One patient (0.5%) had minor bleeding after catheter insertion but no other complications were recorded. A total of 17 patients (9.6%) had lines removed or exchanged due to infection at a median of 86 (range: 13-626) days, while 68 patients (38.4%) had lines removed or exchanged due to dysfunction at a median of 42 (range: 1-531) days. A total of 92 patients (51.9%) had lines removed due to completion of therapy at a median of 68 (range: 7-433) days. Dysfunctional lines had a shorter time-to-removal than successful lines (p = 0.007). No difference was seen in time-to-removal between infected lines and successful lines (p = 0.16). Multivariate analysis showed that female sex (p = 0.003) and left-sided line placement (p = 0.007) were independent predictors of line dysfunction. No evaluated factors were predictive of tunneled hemodialysis catheter infection. Conclusion: Female sex and left-sided line placement were independent predictors of tunneled hemodialysis catheter dysfunction, but none of the evaluated parameters predicted tunneled hemodialysis catheter infection.
引用
收藏
页码:380 / 385
页数:6
相关论文
共 50 条
  • [1] Prevalence and Predictors of Tunneled Dialysis Catheter Dysfunction
    Rozenberg, Ilan
    Benchetrit, Sydney
    Zitman-Gal, Tali
    Ajaj, Moanis
    Shehab, Maysam
    Nacasch, Naomi
    Cohen-Hagai, Keren
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2024, 26 (09): : 508 - 513
  • [2] Tunneled Internal Jugular Hemodialysis Catheters: Impact of Laterality and Tip Position on Catheter Dysfunction and Infection Rates
    Engstrom, Bjorn I.
    Horvath, Jeffrey J.
    Stewart, Jessica K.
    Sydnor, Ryan H.
    Miller, Michael J.
    Smith, Tony P.
    Kim, Charles Y.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (09) : 1295 - 1302
  • [3] Tunneled Hemodialysis Catheter Tip Design and Risk of Catheter Dysfunction: An Australian Nationwide Cohort Study
    Lazarus, Benjamin
    Polkinghorne, Kevan R.
    Gallagher, Martin
    Coggan, Sarah
    Gray, Nicholas A.
    Talaulikar, Girish
    Kotwal, Sradha
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2024, 83 (04) : 445 - 455
  • [4] A longitudinal study of the repeated use of alteplase as therapy for tunneled hemodialysis catheter dysfunction
    Little, MA
    Walshe, JJ
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 39 (01) : 86 - 91
  • [5] Dislocation of a Double-Lumen Tunneled Hemodialysis Catheter Causing Dysfunction and Bleeding
    Haid, B.
    Zitt, E.
    Meusburger, E.
    Woess, E.
    Lhotta, K.
    BLOOD PURIFICATION, 2009, 27 (02) : 172 - 173
  • [6] Extravascular misplacement of the tunneled hemodialysis catheter
    Castro-Vilanova, M. J.
    Millan, B.
    Novoa, D.
    Arcocha, V.
    NEFROLOGIA, 2008, 28 (06): : 660 - 661
  • [7] Antibiotic Catheter Locks in the Treatment of Tunneled Hemodialysis Catheter-Related Blood Stream Infection
    Joshi, Amit J.
    Hart, Peter D.
    SEMINARS IN DIALYSIS, 2013, 26 (02) : 223 - 226
  • [8] Reducing tunneled catheter-related infection in hemodialysis patients with nationwide standardization of catheter care protocol
    Lee, Kian-Guan
    Ng, Li Choo
    Yeon, Wenxiang
    Thore, Sumathi Silva
    Abd Rahman, Maslinna
    Rofi, Siti Nurhidayah Mohamed
    Lim, Wei Wei
    Ling, Moi Lin
    Choong, Hui Lin
    JOURNAL OF VASCULAR ACCESS, 2018, 19 (01): : 110 - 111
  • [9] Extreme placement of a tunneled cuffed catheter for hemodialysis
    Donati, Gabriele
    Gargiulo, Mauro
    Ullo, Ines
    Mauro, Raffaella
    Cuna, Vania
    Capelli, Irene
    Cappuccilli, Maria
    D'Arcangelo, Giovanni Liviano
    La Manna, Gaetano
    JOURNAL OF VASCULAR ACCESS, 2017, 18 (05): : E74 - E75
  • [10] Taurolidine-based catheter lock regimen significantly reduces overall costs, infection, and dysfunction rates of tunneled hemodialysis catheters
    Winnicki, Wolfgang
    Herkner, Harald
    Lorenz, Matthias
    Handisurya, Ammon
    Kikic, Zeljko
    Bielesz, Bernhard
    Schairer, Benjamin
    Reiter, Thomas
    Eskandary, Farsad
    Sunder-Plassmann, Gere
    Sengoelge, Guerkan
    KIDNEY INTERNATIONAL, 2018, 93 (03) : 753 - 760