Degradation of secondary polyamide reverse osmosis membrane by hypochlorite in the presence of calcium ions

被引:8
|
作者
Hashiba, Koki [1 ]
Nakai, Satoshi [1 ]
Nishijima, Wataru [2 ]
Ohno, Masaki [3 ]
Gotoh, Takehiko [1 ]
机构
[1] Hiroshima Univ, Grad Sch Engn, Dept Chem Engn, Hiroshima 7398527, Japan
[2] Hiroshima Univ, Environm Res & Management Ctr, Hiroshima 7398527, Japan
[3] Niigata Univ Pharm & Appl Life Sci, Dept Appl Life Sci, Niigata 9568603, Japan
关键词
Acceleration; Calcium ion; Degradation; Hypochlorite; Secondary polyamide membrane; FILM COMPOSITE MEMBRANES; FREE CHLORINE-KINETICS; ACTIVE LAYERS; METAL-IONS; EXPOSURE; MONOCHLORAMINE; PERFORMANCE; MECHANISMS; DYNAMICS; INSIGHTS;
D O I
10.1016/j.polymdegradstab.2020.109351
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Certain metal ions accelerate deterioration of secondary polyamide reverse osmosis membranes during hypochlorite treatment. However, the mechanisms underlying this metal ion-mediated membrane deterioration have not been clarified. Here, we examined the deterioration of a secondary polyamide reverse osmosis membrane during hypochlorite treatment at various pHs by Ca2+, one of the most abundant ions in surface water. In the presence of Ca2+, accelerated membrane deterioration was observed after chlorination and hydrolysis treatment. In addition, the greater membrane deterioration was observed under neutral and alkaline conditions than under acidic conditions, suggesting that Ca2+ might accelerate hydrolysis rather than chlorination. X-ray photoelectron spectroscopy analysis confirmed that the Cl atomic concentration in the active layer was increased by hypochlorite treatment; however, the presence of Ca2+ did not enhance chlorination of the membrane. In addition, measurement of the water contact angle of the active layer of membranes treated by hypochlorite in the presence of Ca2+ showed a significant increase of wettability. Together, these results provided the evidence that Ca2+ increased hydrolysis rather than chlorination. Solid-state C-13 nuclear magnetic resonance spectra of the membranes after hypochlorite treatment showed a signal attributed to the -C*-NH2 of phenylenediamine structures in the active layer, the intensity of which was increased in the presence of Ca2+, indicating that the presence of Ca2+ in hypochlorite treatment resulted in increased hydrolysis of the polyamide structure. In addition, evolved gas analysis-mass spectrometry analysis provided further evidence supporting the production of ions with an m/z of 108, which corresponds to phenylenediamine. Together, the present results showed that deterioration of polyamide membrane by hypochlorite is increased in the presence of Ca2+ via acceleration of hydrolysis but not of chlorination. Based on these findings, we proposed a mechanism for the accelerated degradation of polyamide membrane by Ca2+. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Effect of coexisting metal ions on the degradation of polyamide reverse osmosis membrane by hypochlorite treatment
    Ohno, Masaki
    Manalo, Cervinia
    Rossetto, Laura
    Okuda, Tetsuji
    Nakai, Satoshi
    Nishijima, Wataru
    DESALINATION, 2016, 381 : 126 - 134
  • [2] Study on hypochlorite degradation of aromatic polyamide reverse osmosis membrane
    Kang, Guo-Dong
    Gao, Cong-Jie
    Chen, Wei-Dong
    Jie, Xing-Ming
    Cao, Yi-Ming
    Yuan, Quan
    JOURNAL OF MEMBRANE SCIENCE, 2007, 300 (1-2) : 165 - 171
  • [3] Potential applications of abandoned aromatic polyamide reverse osmosis membrane by hypochlorite degradation
    Zeng, Ganning
    Lian, Guannan
    Zhang, Yicheng
    Gan, Lu
    Zhou, Yong
    Qiu, Junhong
    van der Bruggencd, Bart
    Shen, Jiangnan
    RSC ADVANCES, 2016, 6 (15): : 12263 - 12271
  • [4] Degradation of Polyamide Nanofiltration and Reverse Osmosis Membranes by Hypochlorite
    Van Thanh Do
    Tang, Chuyang Y.
    Reinhard, Martin
    Leckie, James O.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (02) : 852 - 859
  • [5] Hypochlorite treatment of polyamide membrane for improved reverse osmosis performance
    Shao, P.
    Kurth, C. J.
    MEMBRANE WATER TREATMENT, 2013, 4 (01) : 69 - 81
  • [6] Deterioration Mechanism of a Tertiary Polyamide Reverse Osmosis Membrane by Hypochlorite
    Hashiba, Koki
    Nakai, Satoshi
    Ohno, Masaki
    Nishijima, Wataru
    Gotoh, Takehiko
    Iizawa, Takashi
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (15) : 9109 - 9117
  • [7] Hypochlorite treatment of polyamide membrane for improved reverse osmosis performance
    Shao, P.
    Kurth, C.J.
    Membrane Water Treatment, 2012, 4 (01) : 69 - 81
  • [8] Assessing the oxidative degradation of polyamide reverse osmosis membrane-Accelerated ageing with hypochlorite exposure
    Antony, Alice
    Fudianto, Rudy
    Cox, Shane
    Leslie, Greg
    JOURNAL OF MEMBRANE SCIENCE, 2010, 347 (1-2) : 159 - 164
  • [9] Degradation of polyamide reverse osmosis membranes in the presence of chloramine
    Cran, Marlene J.
    Bigger, Stephen W.
    Gray, Stephen R.
    DESALINATION, 2011, 283 : 58 - 63
  • [10] Effects of membrane chemistry on hypochlorite degradation of nanofiltration and reverse osmosis membranes
    Tang, Chuyang Y.
    Thanh Van Do
    Reinhard, Martin
    Leckie, James O.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243