Study and Implementation of Closed Loop Control Based on Double Synchronous Rotating Frame for EMU Auxiliary Inverter with Unbalanced Load

被引:0
|
作者
Du, Huiqing [1 ]
Liu, Zhigang [1 ]
Fu, Yao [1 ]
Wang, Lei [1 ]
Diao, Lijun [1 ]
机构
[1] Beijing Jiaotong Univ, Sch Elect Engn, Beijing, Peoples R China
关键词
Auxiliary inverter; Unbalanced load; Method of symmetrical component; Double-loop control; Double synchronous rotating frame; NONLINEAR LOADS;
D O I
10.1007/978-3-642-53751-6_15
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
As one of the EMU auxiliary inverter's important performances, the symmetry of three-phase voltage puts forward high requirement in the inverter's topologies and control strategies. Based on the method of symmetrical component, this paper builds positive-, negative-, and zero-sequence mathematical model of the three-phase inverter system with unbalanced load, and then analyses the generation mechanism of asymmetry output voltage. Afterwards it is proposed a double-loop SVPWM control strategy based on double synchronous rotating frame, and further analysis of the working mechanism and realization mode is raised. Finally, it turns out to be reliable and feasible to apply the control strategy after being tested with virtual DSP simulation model with MATLAB, and on a 3 kVA experimental prototype.
引用
收藏
页码:147 / 159
页数:13
相关论文
共 39 条
  • [1] Study of closed loop control based on double synchronous rotating frame for two-stage matrix converter under unbalanced load
    Institute of Information and Engineering, Xiangtan University, Xiangtan 411105, China
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2006, 19 (70-75):
  • [2] Study of EMU auxiliary inverter double-loop control strategy with PR controller in nonlinear load condition
    Du Huiqing
    Wang Lei
    2013 FOURTH INTERNATIONAL CONFERENCE ON DIGITAL MANUFACTURING AND AUTOMATION (ICDMA), 2013, : 1240 - 1244
  • [3] Synchronous Vibration Control of MSCSG Based on High-Precision Closed-Loop Synchronous Rotating Frame Transformation
    Han, Wenjing
    Cai, Yuanwen
    Han, Wenting
    Yu, Chunmiao
    Ren, Yuan
    Wang, Weijie
    Yin, Zengyuan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (04) : 4793 - 4804
  • [4] A double-loop control strategy for three-phase inverter with unbalanced load
    Wang, Hengli
    Fu, Lijun
    Xiao, Fei
    Jie, Guisheng
    Zhu, Wei
    Dianwang Jishu/Power System Technology, 2013, 37 (02): : 398 - 404
  • [5] Study on the Simulation for Closed-Loop Control Based on Synchronous Rotating Coordinate for MC
    Huai, Wen-Jun
    Zhang, Jin-Feng
    Ren, She-Yi
    2010 INTERNATIONAL CONFERENCE ON COMMUNICATION AND VEHICULAR TECHNOLOGY (ICCVT 2010), VOL II, 2010, : 94 - 97
  • [6] Study on the Simulation for Closed-Loop Control Based on Synchronous Rotating Coordinate for MC
    Huai, Wen-Jun
    Zhang, Jin-Feng
    Ren, She-Yi
    2012 INTERNATIONAL CONFERENCE ON FUTURE ELECTRICAL POWER AND ENERGY SYSTEM, PT B, 2012, 17 : 1281 - 1287
  • [7] Unbalanced Load Compensation by Power-Based Control in the Synchronous Reference Frame
    Gothner, F.
    Brandao, D., I
    Tedeschi, E.
    2019 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE 2019 - ECCE ASIA), 2019, : 1383 - 1388
  • [8] Research on Double Buck Inverter Based on Double Closed-loop Control
    Yue, Zhou
    PROCEEDINGS OF THE 39TH CHINESE CONTROL CONFERENCE, 2020, : 1203 - 1208
  • [9] Grid-connected auxiliary inverter control of EMU based on coordinate transformation phase-locked loop
    Li, Wei
    Zhang, Li
    Zhao, Zhen
    Ma, Chi
    Zhongguo Tiedao Kexue/China Railway Science, 2011, 32 (05): : 100 - 103
  • [10] A High-Frequency Inverter Based on Double Closed-loop Control
    Yang, Lin
    Liu, Genwang
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 509 - 512