Optimization and Validation of an ETAAS Method for the Determination of Nickel in Postmortem Material

被引:4
|
作者
Dudek-Adamska, Danuta [1 ]
Lech, Teresa [2 ]
Koscielniak, Pawel [1 ]
机构
[1] Jagiellonian Univ, PL-30060 Krakow, Poland
[2] Inst Forens Res, PL-31033 Krakow, Poland
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; ELEMENT REFERENCE VALUES; TRACE-ELEMENTS; EMISSION-SPECTROMETRY; BIOLOGICAL MATRICES; EUROPEAN-COMMUNITY; WHOLE-BLOOD; ICP-MS; URINE; PLASMA;
D O I
10.1093/jat/bkv039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, optimization and validation of a procedure for the determination of total nickel in wet digested samples of human body tissues (internal organs) for forensic toxicological purposes are presented. Four experimental setups of the electrothermal atomic absorption spectrometry (ETAAS) using a Solaar MQZe (Thermo Electron Co.) were compared, using the following (i) no modifier, (ii) magnesium nitrate, (iii) palladium nitrate and (iv) magnesium nitrate and ammonium dihydrogen phosphate mixture as chemical modifiers. It was ascertained that the ETAAS without any modifier with 1,300/2,400 degrees C as the pyrolysis and atomization temperatures, respectively, can be used to determine total nickel at reference levels in biological materials as well as its levels found in chronic or acute poisonings. The method developed was validated, obtaining a linear range of calibration from 0.76 to 15.0 mu g/L, limit of detection at 0.23 mu g/L, limit of quantification at 0.76 mu g/L, precision (as relative standard deviation) up to 10% and accuracy of 97.1% for the analysis of certified material (SRM 1577c Bovine Liver) and within a range from 99.2 to 109.9% for the recovery of fortified liver samples.
引用
收藏
页码:460 / 464
页数:5
相关论文
共 50 条
  • [1] Optimization and Validation of a Procedure for the Determination of Total Chromium in Postmortem Material by ETAAS
    Lech, Teresa
    Dudek-Adamska, Danuta
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2013, 37 (02) : 97 - 101
  • [2] ETAAS determination of nickel in serum and urine
    Todorovska, N
    Karadjova, I
    Stafilov, T
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (4-5) : 310 - 313
  • [3] ETAAS determination of nickel in serum and urine
    Nadica Todorovska
    Irina Karadjova
    Trajče Stafilov
    Analytical and Bioanalytical Chemistry, 2002, 373 : 310 - 313
  • [4] Development and Validation of an ETAAS Method for the Determination of Tin in Canned Tomato Paste Samples
    Ioannis N. Pasias
    Vassiliki Papageorgiou
    Nikolaos S. Thomaidis
    Charalampos Proestos
    Food Analytical Methods, 2012, 5 : 835 - 840
  • [5] Development and Validation of an ETAAS Method for the Determination of Tin in Canned Tomato Paste Samples
    Pasias, Ioannis N.
    Papageorgiou, Vassiliki
    Thomaidis, Nikolaos S.
    Proestos, Charalampos
    FOOD ANALYTICAL METHODS, 2012, 5 (04) : 835 - 840
  • [6] THE VALIDATION OF THE QUANTITATIVE HISTOCHEMICAL METHOD FOR USE ON HUMAN POSTMORTEM MATERIAL
    SMITH, DE
    ROBINS, E
    EYDT, KM
    DAESCH, GE
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1956, 4 (05) : 420 - 421
  • [7] A rapid solid sampling method for determination of nickel and copper along human hair by ETAAS
    Baysal, Asli
    Akman, Suleyman
    MICROCHEMICAL JOURNAL, 2011, 98 (02) : 291 - 296
  • [8] Application of the fast ETAAS method for the determination of chromium, cobalt and nickel in samples of preserved food
    Baralkiewicz, D
    Karas, Z
    Siepak, J
    CHEMIA ANALITYCZNA, 1997, 42 (05): : 691 - 695
  • [9] Determination of copper in wine by ETAAS using conventional and fast thermal programs: Validation of analytical method
    Catarino, S
    Pimentel, I
    Curvelo-Garcia, AS
    ATOMIC SPECTROSCOPY, 2005, 26 (02) : 73 - 78
  • [10] A generalized method for the determination of nickel in different samples by ETAAS after rapid microwave-assisted digestion
    Chakraborty, R
    Das, AK
    Cervera, ML
    delaGuardia, M
    ANALYTICAL LETTERS, 1997, 30 (02) : 283 - 303