Detection of COD UV Absorption Spectra Based on PSO-PLS Hybrid Algorithm

被引:4
|
作者
Zheng Pei-chao [1 ]
Zhao Wei-neng [1 ]
Wang Jin-mei [1 ]
Lai Chun-hong [1 ]
Wang Xiao-fa [1 ]
Mao Xue-feng [1 ]
机构
[1] Chongqing Univ Posts & Telecommun, Coll Optoelect Engn, Chongqing Municipal Level Key Lab Photoelect Info, Chongqing 400065, Peoples R China
关键词
Particle swarm optimization; UV absorption spectroscopy; COD measurement; PLS regression; CHEMICAL OXYGEN-DEMAND; OPTIMIZATION;
D O I
10.3964/j.issn.1000-0593(2021)01-0136-05
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Chemical oxygen demand ( COD) is an important indicator of the degree of water pollution by organic matter. Ultraviolet absorption spectroscopy is the most widely used method for COD detection in water. It has the advantages of no pretreatment of samples, low cost, no pollution, and fast measurement speed. However, the original spectral data has high dimensions, and the spectral information contains a large number of redundant variables. Modeling the full spectral data has problems such as low accuracy and complicated calculations. Aiming at the low accuracy of UV absorption full-spectrum modeling and a large amount of collinearity in spectral data, this paper presents a method based on particle swarm optimization (PSO) and partial least squares (PLS) to select characteristic wavelengths to establish a prediction model. Improve the accuracy and applicability of the UV absorption spectrum prediction model and simplify the model. The UV spectrum data of 29 different concentrations of COD standard solutions were collected. Each standard solution was collected 5 times and averaged and smoothed to reduce the errors caused by the instrument and the environment. Taking into account the absorption of the standard solution in the spectral range of 200 similar to 310 nm, 246 wavelength points in this wavelength range were selected as modeling data, and the absorbance data at each wavelength point was used as a particle and numbered in order. PLS was used as the model Method, the correlation coefficient r and the root mean square error (RMSE) are used as evaluation indicators. The particle swarm algorithm fitness function f (x) = min (RMSE) is set. The initial population of particles is 20, the inertia weight w=0. 6, and the self The learning factor c1=1. 6, the group learning factor c2=1. 6, the maximum number of iterations is 200, and the algorithm termination condition is to reach the maximum number of iterations. The output value of the optimal global variable of the algorithm is 168, 94, 181, 183, 175, 209, 106, 142. The correlation coefficient r and the predicted root mean square error RMSE of the PLS prediction model established by the eight wavelength points selected by the particle swarm optimization algorithm were 0. 999 98 and 0. 155 1, respectively. In order to verify the effectiveness of the prediction model established by PSO-PLS, three prediction models of PLS, iPLS and SVR were established for comparison. The verification results show that the correlation coefficient r and the root mean square error RMSE of the PSO-PLS model are better than those of the other three prediction models, which shows that the particle swarm algorithm can effectively extract the characteristic wavelengths used for PLS modeling and eliminate the common of sub-interval variables Linear, improving the accuracy of the prediction model. This method provides an effective way for real-time online monitoring of COD in water bodies.
引用
收藏
页码:136 / 140
页数:5
相关论文
共 7 条
  • [1] Development of variable pathlength UV-vis spectroscopy combined with partial-least-squares regression for wastewater chemical oxygen demand (COD) monitoring
    Chen, Baisheng
    Wu, Huanan
    Li, Sam Fong Yau
    [J]. TALANTA, 2014, 120 : 325 - 330
  • [2] Determination of chemical oxygen demand (COD) using an alternative wet chemical method free of mercury and dichromate
    Kolb, Marit
    Bahadir, Muefit
    Teichgraeber, Burkhard
    [J]. WATER RESEARCH, 2017, 122 : 645 - 654
  • [3] Optimization of COD determination by UV-vis spectroscopy using PLS chemometrics algorithms
    Li, Jingwei
    Tong, Yifei
    Guan, Li
    Wu, Shaofeng
    Li, Dongbo
    [J]. OPTIK, 2018, 174 : 591 - 599
  • [4] FTIR/ATR Spectroscopy Applied to the Rapid Determination of Chemical Oxygen Demand of Wastewater
    Pan, Tao
    Ji, Qiang
    Chen, Jiemei
    Chen, Huazhou
    [J]. ADVANCED MATERIALS IN MICROWAVES AND OPTICS, 2012, 500 : 820 - 825
  • [5] Performance Assessment of a Coupled Particle Swarm Optimization and Network Flow Programming Model for Optimum Water Allocation
    Shourian, Mojtaba
    Mousavi, S. Jamshid
    [J]. WATER RESOURCES MANAGEMENT, 2017, 31 (15) : 4835 - 4853
  • [6] Tang Bin Tang Bin, 2015, China Environmental Science, V35, P478
  • [7] Seasonal dynamics of constitutive levels of phenolic components lead to alterations of antioxidant capacities in Acer truncatum leaves
    Yang, Lingguang
    Yin, Peipei
    Li, Ke
    Fan, Hang
    Xue, Qiang
    Li, Xiang
    Sun, Liwei
    Liu, Yujun
    [J]. ARABIAN JOURNAL OF CHEMISTRY, 2018, 11 (01) : 14 - 25