Deformable registration and region-of-interest image reconstruction in sparse repeat CT scanning

被引:5
|
作者
Adelman, Zeev [1 ]
Joskowicz, Leo [1 ]
机构
[1] Hebrew Univ Jerusalem, Sch Comp Sci & Engn, Jerusalem, Israel
关键词
Sparse CT scanning; repeat scanning; ROI reconstruction; deformable registration; 3D Radon space; COMPUTED-TOMOGRAPHY; SCANS;
D O I
10.3233/XST-200706
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Repeat CT scanning is ubiquitous in many clinical situations, e.g. to follow disease progression, to evaluate treatment efficacy, and to monitor interventional CT procedures. However, it incurs in cumulative radiation to the patient which can be significantly reduced by using a region of interest (ROI) and the existing baseline scan. OBJECTIVE: To obtain a high-quality reconstruction of a ROI with a significantly reduced X-ray radiation dosage that accounts for deformations. METHODS: We present a new method for deformable registration and image reconstruction inside an ROI in repeat CT scans with a highly reduced X-ray radiation dose based on sparse scanning. Our method uses the existing baseline scan data, a user-defined ROI, and a new sparse repeat scan to compute a high-quality repeat scan ROI image with a significantly reduced radiation dose. Our method first performs rigid registration between the densely scanned baseline and the sparsely scanned repeat CT scans followed by deformable registration with a low-order parametric model, both in 3D Radon space and without reconstructing the repeat scan image. It then reconstructs the repeat scan ROI without computing the entire repeat scan image. RESULTS: Our experimental results on clinical lung and liver CT scans yield a mean x 14 computation speedup and a x 7.6-12.5 radiation dose reduction, with a minor image quality loss of 0.0157 in the NRMSE metric. CONCLUSION: Our method is considerably faster than existing methods, thereby enabling intraoperative online repeat scanning that it is accurate and accounts for position, deformation, and structure changes at a fraction of the radiation dose required by existing methods.
引用
收藏
页码:1069 / 1089
页数:21
相关论文
共 50 条
  • [1] Dual-resolution image reconstruction for region-of-interest CT scan
    Jin, S. O.
    Shin, K. Y.
    Yoo, S. K.
    Kim, J. G.
    Kim, K. H.
    Huh, Y.
    Lee, S. Y.
    Kwon, O. -K.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [2] Refining a region-of-interest within an available CT image
    Enjilela, Esmaeil
    Hussein, Esam M. A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2013, 75 : 77 - 84
  • [3] Region-of-interest image reconstruction in circular cone-beam microCT
    Cho, Seungryong
    Bian, Junguo
    Pelizzari, Charles A.
    Chen, Chin-Tu
    He, Tong-Chuan
    Pan, Xiaochuan
    [J]. MEDICAL PHYSICS, 2007, 34 (12) : 4923 - 4933
  • [4] A general region-of-interest image reconstruction approach with truncated Hilbert transform
    Li, Liang
    Kang, Kejun
    Chen, Zhiqiang
    Zhang, Li
    Xing, Yuxiang
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2009, 17 (02) : 135 - 152
  • [5] Region-of-Interest CT Reconstruction Using Object Extent and Singular Value Decomposition
    Coussat, Aurelien
    Rit, Simon
    Clackdoyle, Rolf
    Defrise, Michel
    Desbat, Laurent
    Letang, Jean Michel
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (05) : 537 - 551
  • [6] CNN-based Region-of-Interest Image Reconstruction from Truncated Data in Cone-Beam CT
    Son, Kihong
    Kim, Hyoeun
    Jang, Yurim
    Chae, Seunghoon
    Lee, Sooyeul
    [J]. MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [7] Penalized-likelihood region-of-interest CT reconstruction by local object supersampling
    Hamelin, Benoit
    Goussard, Yves
    Dussault, Jean-Pierre
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 739 - +
  • [8] Mutual information-based methods to improve local region-of-interest image registration
    Wilkie, KP
    Vrscay, ER
    [J]. IMAGE ANALYSIS AND RECOGNITION, 2005, 3656 : 63 - 72
  • [9] Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy
    Cho, Seungryong
    Pearson, Erik
    Pelizzari, Charles A.
    Pan, Xiaochuan
    [J]. MEDICAL PHYSICS, 2009, 36 (04) : 1184 - 1192
  • [10] Region-of-interest reconstruction for a cone-beam dental CT with a circular trajectory
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Zheng, Hairong
    Xia, Dan
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 708 : 39 - 45