Reliability of radiomics features due to image reconstruction using a standardized T2-weighted pulse sequence for MR-guided radiotherapy: An anthropomorphic phantom study

被引:7
|
作者
Xue, Cindy [1 ]
Zhou, Yihang [1 ]
Lo, Gladys Goh [2 ]
Wong, Oi Lei [1 ]
Yu, Siu Ki [1 ]
Cheung, Kin Yin [1 ]
Yuan, Jing [1 ]
机构
[1] Hong Kong Sanat & Hosp, Med Phys & Res Dept, 8-F,Li Shu Fan Block,2 Village Rd, Hong Kong, Peoples R China
[2] Hong Kong Sanat & Hosp, Dept Diagnost & Intervent Radiol, Hong Kong, Peoples R China
关键词
compressed sensing; MR‐ guided radiotherapy; MRI reconstruction; parallel imaging; radiomics; SENSE; SIGNATURE;
D O I
10.1002/mrm.28650
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To prospectively investigate the impact of image reconstruction on MRI radiomics features. Methods An anthropomorphic phantom was scanned at 1.5 T using a standardized sequence for MR-guided radiotherapy under SENSE and compressed-SENSE reconstruction settings. A total of 93 first-order and texture radiomics features in 10 volumes of interest were assessed based on (1) accuracy measured by the percentage deviation from the reference, (2) robustness on reconstruction in all volumes of interest measured by the intraclass correlation coefficient, and (3) repeatability measured by the coefficient of variance over the repetitive acquisitions. Finally, reliable and unreliable radiomics features were comprehensively determined based on their accuracy, robustness, and repeatability. Results Better accuracy and robustness of the radiomics features were achieved under SENSE than compressed-SENSE reconstruction. The feature accuracy under SENSE reconstruction was more affected by acceleration factor than direction, whereas under compressed-SENSE reconstruction, accuracy was substantially impacted by the increasing denoising levels. Feature repeatability was dependent more on feature types than on reconstruction. A total of 45 reliable features and 13 unreliable features were finally determined for SENSE, compared with 22 reliable and 26 unreliable features for compressed SENSE. First-order and gray-level co-occurrence matrix features were generally more reliable than other features. Conclusion Radiomics features could be substantially affected by MRI reconstruction, so precautions need to be taken regarding their reliability for clinical use. This study helps the guidance of the preselection of reliable radiomics features and the preclusion of unreliable features in MR-guided radiotherapy.
引用
收藏
页码:3434 / 3446
页数:13
相关论文
共 14 条
  • [1] Quantitative assessment of acquisition imaging parameters on MRI radiomics features: a prospective anthropomorphic phantom study using a 3D-T2W-TSE sequence for MR-guided-radiotherapy
    Yuan, Jing
    Xue, Cindy
    Lo, Gladys
    Wong, Oi Lei
    Zhou, Yihang
    Yu, Siu Ki
    Cheung, Kin Yin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (05) : 1870 - +
  • [2] MR-guided biopsy using a T2-weighted single-shot Zoom-imaging sequence (Local Look Technique)
    Buecker, A
    Adam, GB
    Neuerburg, J
    Glowinski, A
    VanVaals, JJ
    Guenther, RW
    RADIOLOGY, 1997, 205 : 155 - 155
  • [3] MR-guided biopsy using respiratory-triggered high-resolution T2-weighted sequences
    Langen, HJ
    Kugel, H
    Grewe, S
    Gindele, A
    Landwehr, P
    Fischbach, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) : 834 - 836
  • [4] Fast T2-weighted MR imaging: impact of variation in pulse sequence parameters on image quality and artifacts
    Li, T
    Mirowitz, SA
    MAGNETIC RESONANCE IMAGING, 2003, 21 (07) : 745 - 753
  • [5] A study of T2-weighted MR image texture features and diffusion-weighted MR image features for computer-aided diagnosis of prostate cancer
    Peng, Yahui
    Jiang, Yulei
    Antic, Tatjana
    Giger, Maryellen L.
    Eggener, Scott
    Oto, Aytekin
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [6] Evaluation of T2-Weighted MRI Pulse Sequences for Visualization and Sparing of Urethra with MR-Guided Radiation Therapy (MRgRT) On-Board MRI
    Pham, J.
    Savjani, R.
    Gao, Y.
    Cao, M.
    Hu, P.
    Low, D.
    Steinberg, M.
    Kishan, A.
    Yang, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E616 - E616
  • [7] T2-WEIGHTED SPIN-ECHO PULSE SEQUENCE WITH VARIABLE REPETITION AND ECHO TIMES FOR REDUCTION OF MR IMAGE ACQUISITION TIME
    BUTTS, RK
    FARZANEH, F
    RIEDERER, SJ
    RYDBERG, JN
    GRIMM, RC
    RADIOLOGY, 1991, 180 (02) : 551 - 556
  • [8] MR-Guided Sclerotherapy of Low-Flow Vascular Malformations Using T2-Weighted Interrupted bSSFP (T2W-iSSFP): Comparison of Pulse Sequences for Visualization and Needle Guidance
    Xu, Di
    Herzka, Daniel A.
    Gilson, Wesley D.
    McVeigh, Elliot R.
    Lewin, Jonathan S.
    Weiss, Clifford R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (02) : 525 - 535
  • [9] Robustness and reproducibility of radiomics in T2 weighted images from magnetic resonance image guided linear accelerator in a phantom study
    Sun, Mengdi
    Baiyasi, Ahmad
    Liu, Xuechun
    Shi, Xihua
    Li, Xu
    Zhu, Jian
    Yin, Yong
    Hu, Jiani
    Li, Zhenjiang
    Li, Baosheng
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 96 : 130 - 139
  • [10] A multicenter study on radiomic features from T2-weighted images of a customized MR pelvic phantom setting the basis for robust radiomic models in clinics
    Bianchini, Linda
    Santinha, Joao
    Loucao, Nuno
    Figueiredo, Mario
    Botta, Francesca
    Origgi, Daniela
    Cremonesi, Marta
    Cassano, Enrico
    Papanikolaou, Nikolaos
    Lascialfari, Alessandro
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1713 - 1726