Impact of diet on stool signal in dark lumen magnetic resonance colonography

被引:10
|
作者
Goehde, SC [1 ]
Ajaj, W [1 ]
Lauenstein, T [1 ]
Debatin, JF [1 ]
Ladd, ME [1 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
关键词
magnetic resonance imaging; magnetic resonance colonography; barium; fecal tagging; nutrition; food; relaxation time; signal;
D O I
10.1002/jmri.20098
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the magnetic resonance (MR) properties of different foods and their effect on the colonic stool signal to potentially support fecal tagging strategies for dark lumen MR colonography (MRC). Materials and Methods: T1 relaxation times of 120 different foods (partially diluted with sufficient water) were determined by use of a multi-flip-angle two-dimensional gradient echo (GRE) sequence and correlated to the foods' signal in a three-dimensional GRE volumetric interpolated breath-hold examination (VIBE) sequence. Different dilutions of six foods were examined. VIBE stool signal was determined in six volunteers under two different conditions: after a three-day diet of short T1 food and of long T1 food, respectively. Results: Most foods exhibit short to very short T1 relaxation times. T1 correlates well with the fat-saturated VIBE signal except for fatty products. Diluted food exhibits T1 times similar to water; concentrated food strongly varies according to their T1 values. No significant difference in stool signal could be found in the in vivo examination comparing the two diets. Conclusion: According to our results, a restricted diet strategy to reduce fecal signal for dark lumen MRC is unlikely to be successful. Moreover, the stool signal reduction found in the other fecal tagging studies can be explained at least to a great extent by the relative content of other material with long T1 relaxation times, such as water or oral barium.
引用
收藏
页码:272 / 278
页数:7
相关论文
共 50 条
  • [1] Dark-lumen magnetic resonance colonography
    Goyen, M
    Ajaj, W
    Lauenstein, TC
    [J]. SAUDI MEDICAL JOURNAL, 2006, 27 (01) : 116 - 119
  • [2] Dark lumen magnetic resonance colonography: comparison with conventional colonoscopy for the detection of colorectal pathology
    Ajaj, W
    Pelster, G
    Treichel, U
    Vogt, FM
    Debatin, JF
    Ruehm, SG
    Lauenstein, TC
    [J]. GUT, 2003, 52 (12) : 1738 - 1743
  • [3] Dark-lumen magnetic resonance colonography in patients with suspected sigmoid diverticulitis: a feasibility study
    Waleed Ajaj
    Stefan G. Ruehm
    Thomas Lauenstein
    Susanne Goehde
    Christiane Kuehle
    Christoph U. Herborn
    Jost Langhorst
    Thomas Zoepf
    Guido Gerken
    Mathias Goyen
    [J]. European Radiology, 2005, 15 : 2316 - 2322
  • [4] Dark-lumen magnetic resonance colonography in patients with suspected sigmoid diverticulitis: a feasibility study
    Ajaj, W
    Ruehm, SG
    Lauenstein, T
    Goehde, S
    Kuehle, C
    Herborn, CU
    Langhorst, J
    Zoepf, T
    Gerken, G
    Goyen, M
    [J]. EUROPEAN RADIOLOGY, 2005, 15 (11) : 2316 - 2322
  • [5] Dark lumen magnetic resonance colonography in a rodent polyp model -: Initial experience and demonstration of feasibility
    Herborn, CU
    Yang, F
    Robert, P
    Laclédère, C
    Violas, X
    Bara, J
    Corot, C
    Debatin, JF
    Ruehm, SG
    [J]. INVESTIGATIVE RADIOLOGY, 2004, 39 (12) : 723 - 727
  • [6] Dark-lumen MR colonography
    Ajaj, W
    Debatin, JF
    Lauenstein, T
    [J]. ABDOMINAL IMAGING, 2004, 29 (04): : 429 - 433
  • [7] Dark-lumen MR colonography
    W. Ajaj
    J. F. Debatin
    T. Lauenstein
    [J]. Abdominal Imaging, 2004, 29 : 429 - 433
  • [8] Prospective study on, bright lumen magnetic resonance colonography in comparison with conventional colonoscopy
    Saar, B.
    Meining, A.
    Beer, A.
    Settles, M.
    Helmberger, H.
    Frimberger, E.
    Rummeny, E. J.
    Roesch, T.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (952): : 235 - 241
  • [9] Dark lumen MR colonography for the detection of diverticulosis/diverticulitis
    Lauenstein, TC
    Holtmann, G
    Herborn, CU
    Debatin, JF
    Ruehm, SG
    [J]. RADIOLOGY, 2002, 225 : 446 - 446
  • [10] Dark lumen MR-Colonography:: initial experience
    Lauenstein, TC
    Herborn, CU
    Vogt, FM
    Göhde, SC
    Debatin, JF
    Ruehm, SG
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (09): : 785 - 789