3D imaging of fetus vertebra by synchrotron radiation microtomography

被引:5
|
作者
Peyrin, F
Salome, M
Denis, F
Braillon, P
LavalJeantet, AM
Cloetens, P
机构
来源
关键词
synchrotron radiation; computed microtomography; x-ray; bone density; bone architecture; fetus vertebra;
D O I
10.1117/12.292725
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A synchrotron radiation computed microtomography (SRCMT) system allowing high resolution three-dimensional imaging of bone samples has been developed at ESRF. The system uses a high resolution 2D detector based on a CCD camera coupled to a fluorescent screen through light optics. The spatial resolution of the device is particularly well adapted to the imaging of bone structure. In view of studying growth, vertebra samples of fetus with different gestational ages were imaged. The first results show that fetus vertebra is quite different from adult bone both in terms of density and organization.
引用
收藏
页码:44 / 52
页数:9
相关论文
共 50 条
  • [1] Local reconstruction in 3D Synchrotron Radiation MicroTomography
    Peyrin, F
    Bonnet, S
    Ludwig, W
    Baruchel, J
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 128 - 137
  • [2] Synchrotron Radiation Microtomography for Large Area 3D Imaging of Multilevel Microelectronic Packages
    Elmer, John W.
    Li, Yan
    Barth, Holly D.
    Parkinson, Dilworth Y.
    Pacheco, Mario
    Goyal, Deepak
    [J]. JOURNAL OF ELECTRONIC MATERIALS, 2014, 43 (12) : 4421 - 4427
  • [3] Synchrotron Radiation Microtomography for Large Area 3D Imaging of Multilevel Microelectronic Packages
    John W. Elmer
    Yan Li
    Holly D. Barth
    Dilworth Y. Parkinson
    Mario Pacheco
    Deepak Goyal
    [J]. Journal of Electronic Materials, 2014, 43 : 4421 - 4427
  • [4] 3D microtomography of cancellous bone samples using synchrotron radiation
    Pateyron, M
    Peyrin, F
    LavalJeantet, AM
    Spanne, P
    Cloetens, P
    Peix, G
    [J]. PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 417 - 426
  • [5] Synchrotron X-ray microtomography for 3D imaging of polymer blends
    Pyun, Ahram
    Bell, Joel R.
    Won, Kyu Hwang
    Weon, Byung Mook
    Seol, Seung Kwon
    Je, Jung Ho
    Macosko, Christopher W.
    [J]. MACROMOLECULES, 2007, 40 (06) : 2029 - 2035
  • [6] 3d synchrotron radiation microtomography investigation of bone architecture for a mice model of osteoporosis
    Martín-Badosa, E
    Amblard, D
    Nuzzo, S
    Elmoutaouakkil, A
    Vico, L
    Peyrin, F
    [J]. OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 12 - 12
  • [7] Evaluation of bone mineral content from 3D synchrotron radiation microtomography images
    Nuzzo, S
    Peyrin, F
    Martín-Badosa, E
    Boivin, G
    Lafage-Proust, MH
    [J]. OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 10 - 10
  • [8] 3D histomorphometric quantification of trabecular bones by computed microtomography using synchrotron radiation
    Nogueira, L. P.
    Braz, D.
    Barroso, R. C.
    Oliveira, L. F.
    Pinheiro, C. J. G.
    Dreossi, D.
    Tromba, G.
    [J]. MICRON, 2010, 41 (08) : 990 - 996
  • [9] CHARACTERISATION OF THE 3D PAPER STRUCTURE WITH X-RAY SYNCHROTRON RADIATION MICROTOMOGRAPHY
    du Roscoat, S. Rolland
    Bloch, J-F.
    Thibault, X.
    [J]. ADVANCES IN PAPER SCIENCE AND TECHNOLOGY: TRANSACTIONS OF THE 13TH FUNDAMENTAL RESEARCH SYMPOSIUM, VOLS 1-3, 2005, : 901 - 920
  • [10] 3D imaging of fracture propagation using synchrotron X-ray microtomography
    Renard, Francois
    Bernard, Dominique
    Desrues, Jacques
    Ougier-Simonin, Audrey
    [J]. EARTH AND PLANETARY SCIENCE LETTERS, 2009, 286 (1-2) : 285 - 291