Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

被引:10
|
作者
Brown, Shannon E. [1 ]
Sargent, Steve [2 ]
Wagner-Riddle, Claudia [1 ]
机构
[1] Univ Guelph, Sch Environm Sci, Guelph, ON, Canada
[2] Campbell Sci Inc, Logan, UT USA
关键词
FREQUENCY-RESPONSE CORRECTIONS; GAS ANALYZERS; SPECTRAL CHARACTERISTICS; MANAGED GRASSLAND; DIODE-LASER; N2O FLUXES; EMISSIONS; FIELD; PATH; CO2;
D O I
10.5194/amt-11-1583-2018
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Nitrous oxide (N2O) fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path tracegas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2) The system features a relatively small, single-pass sample cell (200 mL) that provides good frequency response with a lower-powered pump (similar to 250 W). A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016) in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: -26.1 to 31.6 degrees C). The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz) and similar to that of a closed-path CO2 eddy-covariance system (4.05 Hz), using shorter tubing and no dryer, that was also collocated at the site. Values of the N2O fluxes were similar between the two spectrometer systems (slope = 1.01, r(2) = 0.96); CO2 fluxes as measured by the short-tubed eddy-covariance system and the two spectrometer systems correlated well (slope = 1.03, r(2) = 0.998). The new lower-powered tunable diode laser absorption spectrometer configuration with the filterless intake and singletube dryer showed promise for deployment in remote areas.
引用
收藏
页码:1583 / 1597
页数:15
相关论文
共 50 条
  • [1] Eddy-covariance measurements of nitrous oxide fluxes above a city
    Famulari, Daniela
    Nemitz, Elko
    Di Marco, Chiara
    Phillips, Gavin J.
    Thomas, Rick
    House, Emily
    Fowler, David
    [J]. AGRICULTURAL AND FOREST METEOROLOGY, 2010, 150 (06) : 786 - 793
  • [2] Standardisation of eddy-covariance flux measurements of methane and nitrous oxide
    Nemitz, Eiko
    Mammarella, Ivan
    Ibrom, Andreas
    Aurela, Mika
    Burba, George G.
    Dengel, Sigrid
    Gielen, Bert
    Grelle, Achim
    Heinesch, Bernard
    Herbst, Mathias
    Hortnagl, Lukas
    Klemedtsson, Leif
    Lindroth, Anders
    Lohila, Annalea
    McDermitt, Dayle K.
    Meier, Philip
    Merbold, Lutz
    Nelson, David
    Nicolini, Giacomo
    Nilsson, Mats B.
    Peltola, Olli
    Rinne, Janne
    Zahniser, Mark
    [J]. INTERNATIONAL AGROPHYSICS, 2018, 32 (04) : 517 - +
  • [3] Urban nitrous-oxide fluxes measured using the eddy-covariance technique in Helsinki, Finland
    Jarvi, Leena
    Nordbo, Annika
    Rannik, Ullar
    Haapanala, Sami
    Riikonen, Anu
    Mammarella, Ivan
    Pihlatie, Mari
    Vesala, Timo
    [J]. BOREAL ENVIRONMENT RESEARCH, 2014, 19 : 108 - 121
  • [4] Limitations of an Eddy-Covariance System in Measuring Low Ammonia Fluxes
    Ferrara, Rossana Monica
    Di Tommasi, Paul
    Famulari, Daniela
    Rana, Gianfranco
    [J]. BOUNDARY-LAYER METEOROLOGY, 2021, 180 (01) : 173 - 186
  • [5] Limitations of an Eddy-Covariance System in Measuring Low Ammonia Fluxes
    Rossana Monica Ferrara
    Paul Di Tommasi
    Daniela Famulari
    Gianfranco Rana
    [J]. Boundary-Layer Meteorology, 2021, 180 : 173 - 186
  • [6] Correction of eddy-covariance measurements incorporating both advective effects and density fluxes
    Paw U K.T.
    Baldocchi D.D.
    Meyers T.P.
    Wilson K.B.
    [J]. Boundary-Layer Meteorology, 2000, 97 (3) : 487 - 511
  • [7] Correction of eddy-covariance measurements incorporating both advective effects and density fluxes
    Paw, KT
    Baldocchi, DD
    Meyers, TP
    Wilson, KB
    [J]. BOUNDARY-LAYER METEOROLOGY, 2000, 97 (03) : 487 - 511
  • [8] Estimating the uncertainty in annual net ecosystem carbon exchange: spatial variation in turbulent fluxes and sampling errors in eddy-covariance measurements
    Oren, R
    Hseih, CI
    Stoy, P
    Albertson, J
    McCarthy, HR
    Harrell, P
    Katul, GG
    [J]. GLOBAL CHANGE BIOLOGY, 2006, 12 (05) : 883 - 896
  • [9] Permafrost nitrous oxide emissions observed on a landscape scale using the airborne eddy-covariance method
    Wilkerson, Jordan
    Dobosy, Ronald
    Sayres, David S.
    Healy, Claire
    Dumas, Edward
    Baker, Bruce
    Anderson, James G.
    [J]. ATMOSPHERIC CHEMISTRY AND PHYSICS, 2019, 19 (07) : 4257 - 4268
  • [10] Area-Averaged Surface Fluxes Over the Litfass Region Based on Eddy-Covariance Measurements
    Frank Beyrich
    Jens-Peter Leps
    Matthias Mauder
    Jens Bange
    Thomas Foken
    Sven Huneke
    Horst Lohse
    Andreas Lüdi
    Wouter M. L. Meijninger
    Dmitrii Mironov
    Ulrich Weisensee
    Peter Zittel
    [J]. Boundary-Layer Meteorology, 2006, 121 : 33 - 65