A Hybrid Wavelet and Time Plane based method for QT Interval Measurement in ECG Signals

被引:0
|
作者
Majumder, Swanirbhar
Dhar, Sidhartha
Sinha, Abhijit
Roy, Abhijit
机构
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Here we present a method of QT interval measurement for Physionet's online QT Challenge ECG database using the wavelets [1] Daubechies 6 and 8 and Symlet 6 and time plane features [2, 3]. Doing so we found that out of these three wavelets Daubechies 6 gives the best output [1] and when averaged with the interval of time plane feature exit-action method[2,3] it gives least percentage of error with respect to the median reference QT interval [4] as specified by Physionet Our modified time plane feature extraction scheme along with the wavelet method together produces best results for automated QT wave measurement as its regular verification is important for analyzing cardiac health. This is because delay in cardiac repolarization causes ventricular tachyarrhythmias as well as Torsade de pointes (TdP). A feature of TdP is pronounced prolongation of the QT interval in the supraventricular beat preceding the arrhythmia. TdP can degenerate into ventricular fibrillation, leading to sudden death.
引用
收藏
页码:2121 / 2124
页数:4
相关论文
共 50 条
  • [1] Averaging of Time-Warped ECG Signals for QT Interval Measurement
    Moron, Tomasz
    [J]. INFORMATION TECHNOLOGIES IN MEDICINE, ITIB 2016, VOL 1, 2016, 471 : 291 - 302
  • [2] Difference in QT interval measurement on ambulatory ECG compared with standard ECG
    Christiansen, JL
    Guccione, P
    Garson, A
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (09): : 1296 - 1303
  • [3] Implementation of QT Interval Measurement to Remove Errors in ECG
    Chitra, S.
    Jayalakshmi, V
    [J]. INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2022, 13 (02) : 571 - 576
  • [4] Effects of ECG sampling rate on QT interval variability measurement
    Baumert, Mathias
    Schmidt, Martin
    Zaunseder, Sebastian
    Porta, Alberto
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 25 : 159 - 164
  • [5] Lead selection for QT interval measurement for bedside ECG monitoring
    Lo, SL
    Drew, BJ
    [J]. CIRCULATION, 2002, 106 (19) : 489 - 489
  • [6] Accurate wavelet thresholding method for ECG signals
    Yu, Kaimin
    Feng, Lei
    Chen, Yunfei
    Wu, Minfeng
    Zhang, Yuanfang
    Zhu, Peibin
    Chen, Wen
    Wu, Qihui
    Hao, Jianzhong
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2024, 169
  • [7] ECG signals Denoising Method Based on Improved Wavelet Threshold Algorithm
    Zhang Lin
    Lin Jia-lun
    Li Xiao-ling
    Wang Wei-quan
    [J]. PROCEEDINGS OF 2016 IEEE ADVANCED INFORMATION MANAGEMENT, COMMUNICATES, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IMCEC 2016), 2016, : 1779 - 1784
  • [8] 12-Synchronous-lead ECG system and QT interval and QT dispersion measurement
    Zeng, L.P.
    Gao, X.R.
    Li, M.Y.
    Qin, Q.
    [J]. Qinghua Daxue Xuebao/Journal of Tsinghua University, 2000, 40 (09): : 5 - 8
  • [9] QT interval measurement using RMED curve; a novel approach based on wavelet techniques
    Ghasemi, M.
    Ghaffari, A.
    SadAbadi, H.
    Golbayani, H.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (06) : 857 - 864
  • [10] Morphology-based QT Interval Measurement Using Frame-based Representation of the ECG Signal
    Ghodrati, Alireza
    Babajani-Feremi, Abbas
    [J]. 2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 333 - 336