Simultaneous determination of indinavir, ritonavir and saquinavir in plasma by high-performance liquid chromatography

被引:0
|
作者
Hsieh, SM
Yu, HY
Chang, SC
机构
[1] Natl Taiwan Univ, Coll Med, Sch Pharm, Taipei 100, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Internal Med, Div Infect Dis, Taipei 100, Taiwan
关键词
chromatography; high performance liquid; drug monitoring; indinavir; ritonavir; saquinavir;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Purpose: Antiretroviral regimens consisting of a combination of protease inhibitors have been shown to be highly potent for the treatment of HIV infection. Therapeutic drug monitoring may ensure optimal drug levels to improve efficacy and minimize side effects. The purpose of this study was to establish a method for simultaneous determination of plasma concentrations of indinavir (IDV), ritonavir (RTV) and saquinavir (SQV) by high-performance liquid chromatography (HPLC) in a single run. Methods. A C-18 column and an ultraviolet detector set at 215 nm were used in the HPLC. The mobile phase consisted of phosphate buffer (50 mM, pH 5.6) and acetonitrile (55:45, v/v), and the flow rate was 1.5 mL/min. Plasma sample (0.5 mL) containing IDV, RTV, and SQV was alkalinized with ammonia water (10%) and propylparaben added as an internal standard (IS), which was then extracted with methyl tert.-butyl ether. The organic layer was taken and evaporated to dryness. The residue was dissolved in the mobile phase, and the solution was washed with n-hexane followed by HPLC analysis. Results: The calibration curves were linear for each of the 3 drugs in the studied concentration range (0.1 to 5 mug/mL). The extraction recoveries were greater than 90%. One HPLC run takes less than 15 minutes. Analysis of plasma samples of patients treated with combinations of these drugs demonstrated that the calibration curves covered the clinical concentration range. Conclusions: This study established a simple and accurate method for simultaneous determination of IDV, RTV, and SQV in plasma by isocratic HPLC. The method is practical for therapeutic drug monitoring.
引用
收藏
页码:191 / 195
页数:5
相关论文
共 50 条
  • [1] Simultaneous determination of amprenavir, indinavir, nelfinavir, ritonavir, saquinavir in human plasma by high-performance liquid chromatography
    Titier, K.
    Lagrange, F.
    Pehourcq, F.
    Moore, N.
    Begaud, B.
    Molimard, M.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2001, 15 : 65 - 65
  • [2] Simultaneous determination of the HIV protease inhibitors indinavir, amprenavir, saquinavir, ritonavir and nelfinavir in human plasma by high-performance liquid chromatography
    Yamada, H
    Kotaki, H
    Nakamura, T
    Iwamoto, A
    JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2): : 85 - 89
  • [3] Simultaneous determination of indinavir, ritonavir and lopinavir (ABT 378) in human plasma by high-performance liquid chromatography
    Ray, J
    Pang, E
    Carey, D
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 775 (02): : 225 - 230
  • [4] Simultaneous determination of the HIV-protease inhibitors indinavir, nelfinavir, saquinavir and ritonavir in human plasma by reversed-phase high-performance liquid chromatography
    Hugen, PWH
    Verweij-van Wissen, CPWGM
    Burger, DM
    Wuis, EW
    Koopmans, PP
    Hekster, YA
    JOURNAL OF CHROMATOGRAPHY B, 1999, 727 (1-2): : 139 - 149
  • [5] Simultaneous determination of the HIV-protease inhibitors indinavir, amprenavir, ritonavir, saquinavir and nelfinavir in human plasma by reversed-phase high-performance liquid chromatography
    Sarasa-Nacenta, M
    López-Púa, Y
    Mallolas, J
    Blanco, JL
    Gatell, JM
    Carné, X
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 757 (02): : 325 - 332
  • [6] Simultaneous quantitative determination of the HIV protease inhibitors amprenavir, indinavir, nelfinavir, ritonavir and saquinavir in human plasma by ion-pair high-performance liquid chromatography with ultraviolet detection
    van Heeswijk, RPG
    Hoetelmans, RMW
    Harms, R
    Meenhorst, PL
    Mulder, JW
    Lange, JMA
    Beijnen, JH
    JOURNAL OF CHROMATOGRAPHY B, 1998, 719 (1-2): : 159 - 168
  • [7] Determination of saquinavir in human plasma by high-performance liquid chromatography
    Ha, HR
    Follath, F
    Bloemhard, Y
    Krahenbuhl, S
    JOURNAL OF CHROMATOGRAPHY B, 1997, 694 (02): : 427 - 433
  • [8] Simultaneous determination of HIV protease inhibitors amprenavir, atazanavir, indinavir, lopinavir, nelfinavir, ritonavir and saquinavir in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Dickinson, L
    Robinson, L
    Tjia, J
    Khoo, S
    Back, D
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2): : 82 - 90
  • [9] Determination of saquinavir and ritonavir in human plasma by reversed-phase high-performance liquid chromatography and the analytical error function
    Albert, V
    Modamio, P
    Lastra, CF
    Mariño, EL
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (04) : 835 - 840
  • [10] Simultaneous liquid chromatographic determination of Indinavir Saquinavir, and Ritonavir in human plasma with combined ultraviolet absorbance and electrochemical detection
    Marchei, E
    Pacifici, R
    Tossini, G
    Di Fava, R
    Valvo, L
    Zuccaro, P
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (15) : 2325 - 2336