The deformation of an adherent leukocyte under steady shear flow: a numerical study

被引:16
|
作者
Liu, XH
Wang, X
机构
[1] UHP, INPL, CNRS,UMR 7563, LEMTA, F-54500 Vandoeuvre Les Nancy, France
[2] Sichuan Univ, W China Med Ctr, Inst Biomed Engn, Chengdu 610041, Peoples R China
基金
中国国家自然科学基金;
关键词
leukocyte; deformation; numerical simulation; shear flow; adhesion;
D O I
10.1016/j.jbiomech.2003.11.015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Leukocyte adhesion is a pathophysiological process in which the balance between hemodynamic and adhesion forces (molecular bonds) plays a key role. In this work, we studied the deformation of an adherent leukocyte and calculated the forces exerted on it. Three model cells were proposed, considering the leukocyte as a single drop, a compound drop, and a nucleus drop, representing a cell without nucleus, a cell with a nucleus, and a nucleus only, respectively. These model cells were supposedly adherent to a smooth substrate under steady shear flow. Our numerical results showed that all three model cells deformed in function of the initial contact angle, capillary number, and Reynolds number. The single drop was the most deformable, while the nucleus drop was the most resistant to the external flow. Each of the model cells showed maximum cell deformation at a high Reynolds number. The distribution of pressure on the cell confirmed the existence of a high-pressure region downstream of the drop, which retarded further deformation of the cell and provided a positive lift force on the drop. The consideration of a highly viscous nucleus can correct the over evaluation of the cell deformation in a flow. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1079 / 1085
页数:7
相关论文
共 50 条
  • [1] Numerical analysis of the deformation of an adherent drop under shear flow
    Kan, HC
    Udaykumar, HS
    Shyy, W
    Tran-Son-Tay, R
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (02): : 160 - 169
  • [3] Deformation mechanism of leukocyte adhering to vascular surface under steady shear flow
    Liu, XH
    Wang, X
    Yin, HM
    Chen, HQ
    SCIENCE IN CHINA SERIES C-LIFE SCIENCES, 2004, 47 (02): : 165 - 174
  • [4] Deformation mechanism of leukocyte adhering to vascular surface under steady shear flow
    Xiaoheng Liu
    Xiong Wang
    Hongmei Yin
    Huaiqing Chen
    Science in China Series C: Life Sciences, 2004, 47 : 165 - 174
  • [5] Deformation mechanism of leukocyte adhering to vascular surface under steady shear flow
    LIU Xiaoheng1
    2. LEMTA-UMR-CNRS 7563
    3. West China School of Pharmacy
    Science in China(Series C:Life Sciences), 2004, (02) : 165 - 174
  • [6] Study on the deformation of leukocyte adhered to vascular surface under steady shear flow by using a compound drop model
    Liu, Xiaoheng
    Wang, Xiong
    Yin, Hongmei
    Beijing Shengwu Yixue Gongcheng/Beijing Biomedical Engineering, 2003, 22 (04):
  • [7] Cell-fluid Interaction: Coupling Between the Deformation of an Adherent Leukocyte and the Shear Flow
    XH LIU H HUANG C YU MJ ZOU X WANG Institute of Biomedical Engineering Center of West China Medical Sciences Sichuan University Chengdu ChinaLaboratory of Cardiovascular Diseases West China Hospital Sichuan University Chengdu ChinaLEMTAUMRCNRS VandoeuvrelesNancy BP France
    生物医学工程学杂志, 2005, (S1) : 22 - 22
  • [8] Transient and steady deformation of isolated viscoelastic drops under shear flow
    Guido, S
    Villone, M
    XIITH INTERNATIONAL CONGRESS ON RHEOLOGY, PROCEEDINGS, 1996, : 127 - 128
  • [9] NUMERICAL SIMULATION OF THE DEFORMATION OF DROPS UNDER SIMPLE SHEAR FLOW
    Fortin, A.
    Kane, A. S.
    Guenette, R.
    JOURNAL OF POLYMER ENGINEERING, 2010, 30 (08) : 495 - 521
  • [10] Numerical modeling of the deformation in polymer blends under shear flow
    Shahshahani, Azadeh
    Dufour, Steven
    Heuzey, Marie-Claude
    NUMIFORM '07: MATERIALS PROCESSING AND DESIGN: MODELING, SIMULATION AND APPLICATIONS, PTS I AND II, 2007, 908 : 349 - +