Impact of HVAC filter on indoor air quality in terms of ozone removal and carbonyls generation

被引:21
|
作者
Lin, Chi-Chi [1 ]
Chen, Hsuan-Yu [1 ]
机构
[1] Natl Univ Kaohsiung, Dept Civil & Environm Engn, Kaohsiung, Taiwan
关键词
Chamber experiments; HVAC filters; Ozone; Carbonyl; Formaldehyde; Organic carbon; VENTILATION FILTERS; ACTIVATED CARBON; SENSORY POLLUTION; PRODUCTS; POLLUTANTS; DESORPTION; ADSORPTION; AEROSOLS; LEVEL;
D O I
10.1016/j.atmosenv.2014.02.020
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aims at detecting ozone removal rates and corresponding carbonyls generated by ozone reaction with HVAC filters from various building, i.e., shopping mall, school, and office building. Studies were conducted in a small-scale environmental chamber. By examining dust properties including organic carbon proportion and specific surface area of dusts adsorbed on filters along with ozone removal rates and carbonyls generation rate, the relationship among dust properties, ozone removal rates, and carbonyls generation was identified. The results indicate a well-defined positive correlation between ozone removal efficiency and carbonyls generation on filters, as well as a positive correlation among the mass of organic carbon on filters, ozone removal efficiency and carbonyls generations. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 50 条
  • [1] POTENTIAL IMPACT OF DELIBERATELY INTRODUCED OZONE ON INDOOR AIR-QUALITY
    KISSEL, JC
    [J]. JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 1993, 3 (02): : 155 - 164
  • [2] Indoor air quality: Clean, green HVAC machine
    Townsend, Terry
    [J]. FILTRATION + SEPARATION, 2007, 44 (01) : 24 - 26
  • [3] Ozone generation by indoor, electrostatic air cleaners
    Boelter, KJ
    Davidson, JH
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1997, 27 (06) : 689 - 708
  • [4] The relationship between filter pressure drop, indoor air quality, and energy consumption in rooftop HVAC units
    Zaatari, Marwa
    Novoselac, Atila
    Siegel, Jeffrey
    [J]. BUILDING AND ENVIRONMENT, 2014, 73 : 151 - 161
  • [5] Current and recent trend of HVAC filters for Indoor Air Quality
    Choi, KJ
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1228 - 1230
  • [6] Influence of indoor air quality on energy performance of HVAC systems
    Kajtar, Laszlo
    Hrustinszky, Tamas
    [J]. PROCEEDINGS OF THE 6TH IASME/WSEAS INTERNATIONAL CONFERENCE ON HEAT TRANSFER, THERMAL ENGINEERING AND ENVIRONMENT (HTE'08), PTS I AND II: NEW ASPECTS OF HEAT TRANSFER, THERMAL ENGINEERING AND ENVIRONMENT, 2008, : 360 - +
  • [7] Indoor Air Quality Assessment in an Art Gallery with an HVAC System
    Cai, Wei
    Wang, Danjun
    Wen, Xiaodong
    Yu, Xubo
    [J]. 2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [8] Evaluation of ozone generation and indoor organic compounds removal by air cleaners based on chamber tests
    Yu, Kuo-Pin
    Lee, Grace Whei-May
    Hsieh, Ching-Pei
    Lin, Chi-Chi
    [J]. ATMOSPHERIC ENVIRONMENT, 2011, 45 (01) : 35 - 42
  • [9] Enhancing indoor air quality -The air filter advantage
    Vijayan, Vannan Kandi
    Paramesh, Haralappa
    Salvi, Sundeep Santosh
    Dalal, Alpa Anil Kumar
    [J]. LUNG INDIA, 2015, 32 (05) : 473 - 479
  • [10] Indoor air quality impacts of ventilation ducts: Ozone removal and emissions of volatile organic compounds
    Morrison, GC
    Nazaroff, WW
    Cano-Ruiz, JA
    Hodgson, AT
    Modera, MP
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1998, 48 (10): : 941 - 952