Radiation dose absorbed by operators during transradial percutaneous coronary procedures comparing different protective drapes: the RADIATION study

被引:12
|
作者
Sciahbasi, Alessandro [1 ]
Rigattieri, Stefano [1 ]
Sarandrea, Alessandro [2 ]
Cera, Maria [1 ]
Di Russo, Cristian [1 ]
Fedele, Silvio [1 ]
Romano, Silvio [3 ]
Pugliese, Francesco Rocco [1 ]
Penco, Maria [3 ]
机构
[1] Sandro Pertini Hosp, Intervent Cardiol & Emergency Dept, Rome, Italy
[2] HSE Management, Rome, Italy
[3] Univ Aquila, Cardiol Dept, Laquila, Italy
关键词
clinical trials; radial; radiation protection; PELVIC LEAD SHIELD; FEMORAL ACCESS; EXPOSURE; INTERVENTIONS; ANGIOGRAPHY; CATHETERIZATION; METAANALYSIS; REDUCTION; PATIENT; TALENT;
D O I
10.4244/EIJ-D-16-00288
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The aim of this study was to compare different radiation protection drapes in terms of radiation dose absorbed by operators during right or left transradial procedures. Methods and results: Patients who underwent transradial coronary procedures were randomised initially into four groups: Group 1 (no drapes), Group 2 (drape on patients arm), Group 3 (pelvic drape), Group 4 (combined ann and pelvic drapes). Subsequently, each group was further randomised to right or left radial access. The primary endpoint was the operator radiation dose at the thorax. A total of 452 procedures were included. The use of drapes was associated with a lower radiation dose compared to no drapes (8.6 mu Sv [4.1-17.9] Group 1, 5.8 mu Sv [3.4-13] Group 2, 3.6 mu Sv [2.1-6.9] Group 3, 3.7 mu Sv [1.9-10.3] Group 4, p<0.001). Among radiation protection drapes groups the radiation dose was significantly lower in Groups 3 and 4 compared to Group 2 (p<0.008). Compared to Group 1, the dose in Group 2 was significantly lower only in right radial procedures (p<0.008) whereas in Groups 3 and 4 the dose was significantly lower in both radial accesses (p<0.008). Conclusions: The use of radiation protection drapes during transradial coronary procedures is associated with a significantly lower radiation dose to operators, with the pelvic drape more effective than the use of a single ann drape.
引用
收藏
页码:E2253 / E2261
页数:9
相关论文
共 50 条
  • [1] Radiation dose absorbed by operators during transradial percutaneous coronary procedures comparing different protective drapes: the RADIATION study
    Sciahbasi, A.
    Rigattieri, S.
    Sarandrea, A.
    Cera, M.
    Di Russo, C.
    Fedele, S.
    Romano, S.
    Pugliese, F. R.
    Penco, M.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1030 - 1030
  • [2] Staff radiation dose during percutaneous coronary procedures: Role of adjunctive protective drapes
    Sciahbasi, Alessandro
    Sarandrea, Alessandro
    Rigattieri, Stefano
    Patrizi, Roberto
    Cera, Maria
    Di Russo, Cristian
    Perone, Francesco
    Porretta, Vanessa
    Fedele, Silvio
    Romano, Silvio
    Penco, Maria
    Ferraiuolo, Giuseppe
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (07) : 755 - 758
  • [3] Decreasing Operators' Radiation Exposure During Coronary Procedures: The Transradial Radiation Protection Board
    Behan, Miles
    Haworth, Peter
    Colley, Paul
    Brittain, Michael
    Hince, Andrew
    Clarke, Michael
    Ghuran, Azad
    Saha, Mrinal
    Hildick-Smith, David
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (01) : 79 - 84
  • [4] Clinical Determinants of Radiation Dose in Percutaneous Coronary Interventional Procedures
    Fetterly, Kenneth A.
    Lennon, Ryan J.
    Bell, Malcolm R.
    Holmes, David R., Jr.
    Rihal, Charanjit S.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) : 336 - 343
  • [5] Role of Different Adjunctive Protective Devices to Reduce Operator Radiation Exposure in Percutaneous Coronary Procedures: The RAPTOR Study
    Sciahbasi, Alessandro
    Salvi, Nicolo
    Patrizi, Roberto
    Di Russo, Cristian
    Cera, Maria
    Bocci, Alessandro
    Starnazzi, Francesco
    Fedele, Silvio
    Granatelli, Antonino
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2024, 2024
  • [6] Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX)
    Sciahbasi, Alessandro
    Calabro, Paolo
    Sarandrea, Alessandro
    Rigattieri, Stefano
    Tomassini, Francesco
    Sardella, Gennaro
    Zavalloni, Dennis
    Cortese, Bernardo
    Limbruno, Ugo
    Tebaldi, Matteo
    Gagnor, Andrea
    Rubartelli, Paolo
    Zingarelli, Antonio
    Valgimigli, Marco
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2014, 15 (04) : 209 - 213
  • [7] Vascular access and radiation exposure during percutaneous coronary procedures
    Sciahbasi, Alessandro
    Babbaro, Mario
    Confessore, Pierpaolo
    Cera, Maria
    Di Russo, Cristian
    Patrizi, Roberto
    Fedele, Silvio
    MINERVA CARDIOANGIOLOGICA, 2020, 68 (06): : 592 - 598
  • [8] Anthropometric parameters and radiation doses during percutaneous coronary procedures
    Manicardi, Marcella
    Nocetti, Luca
    Brigidi, Alessio
    Cadioli, Cecilia
    Sgreccia, Daria
    Valenti, Anna Chiara
    Vitolo, Marco
    Arrotti, Salvatore
    Monopoli, Daniel Enrique
    Sgura, Fabio
    Rossi, Rosario
    Guidi, Gabriele
    Boriani, Giuseppe
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 100 : 164 - 175
  • [9] Operator Pelvic Radiation Exposure During Percutaneous Coronary Procedures
    Sciahbasi, Alessandro
    Piccaluga, Emanuela
    Sarandrea, Alessandro
    Nucci, Giacomo
    Caretto, Nicola
    Rigattieri, Stefano
    Fedele, Silvio
    Romano, Silvio
    Penco, Maria
    JOURNAL OF INVASIVE CARDIOLOGY, 2018, 30 (02): : 71 - 74
  • [10] Determinants of operator radiation exposure during percutaneous coronary procedures
    Sciahbasi, Alessandro
    Rigattieri, Stefano
    Sarandrea, Alessandro
    Cera, Maria
    Di Russo, Cristian
    Fedele, Silvio
    Patrizi, Roberto
    Romano, Silvio
    Pugliese, Francesco Rocco
    Penco, Maria
    Pancholy, Samir B.
    AMERICAN HEART JOURNAL, 2017, 187 : 10 - 18