A filtering method for signal equalization in region-of-interest fluoroscopy

被引:9
|
作者
Robert, N
Komljenovic, PT
Rowlands, JA
机构
[1] Canadian Heart Res Ctr, Toronto, ON M5H 4E6, Canada
[2] Univ Toronto, Sunnybrook & Womens Coll Hlth Sci Ctr, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
关键词
fluoroscopy; angiography; coronary angiograms; ROI fluoroscopy; equalization;
D O I
10.1118/1.1470205
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method to significantly reduce the exposure area product in fluoroscopy using a pre-patient region-of-interest (ROI) attenuator is presented. The attenuator has a thin central region and a gradually increasing thickness away from the center. It is shown that the unwanted brightening artifact caused by the attenuator can be eliminated by attenuating the low spatial frequencies in the detected image using digital image processing techniques. An investigation of the best image processing method to correct for the presence of the attenuator is undertaken. The correction procedure selected is suitable for use with real-time image processors and the ROI attenuator can be permitted to move during image acquisition. Images of an anthropomorphic chest phantom acquired in the presence of the ROI attenuator using an x-ray image intensifier/video chain are corrected to illustrate the clinical feasibility of our approach. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:736 / 747
页数:12
相关论文
共 50 条
  • [1] Real-time contrast and brightness equalization in region-of-interest fluoroscopy
    Rudin, S
    Bednarek, DR
    [J]. RADIOLOGY, 1996, 201 : 688 - 688
  • [2] REGION-OF-INTEREST FLUOROSCOPY AND ANGIOGRAPHY IN INTERVENTIONAL RADIOLOGY
    RUDIN, S
    BEDNAREK, DR
    GRANGER, W
    HOPKINS, LN
    GUTERMAN, LR
    WAKHLOO, AK
    [J]. RADIOLOGY, 1995, 197 : 289 - 289
  • [3] REGION-OF-INTEREST FLUOROSCOPY APPLIED TO INTERVENTIONAL RADIOLOGIC PROCEDURES
    RUDIN, S
    BEDNAREK, DR
    [J]. RADIOLOGY, 1992, 185 : 159 - 160
  • [4] Organ and effective dose reduction for region-of-interest (ROI) CBCT and fluoroscopy
    Xiong, Zhenyu
    Vijayan, Sarath
    Rudin, Stephen
    Bednarek, Daniel R.
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [5] A vehicle number plate recognition system using region-of-interest based filtering method
    Ghosh, Rajib
    Thakre, Suraj
    Kumar, Prabhat
    [J]. 2018 CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY (CICT'18), 2018,
  • [6] Demonstration of real-time equalization of region-of-interest fluoroscopic images
    Rudin, S
    Bednarek, DR
    Massoumzadeh, P
    Kezerashvili, M
    Granger, WE
    [J]. RADIOLOGY, 1996, 201 : 795 - 795
  • [7] A Kalman filtering approach to stochastic global and region-of-interest tomography
    Luo, DSS
    Yagle, AE
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (03) : 471 - 479
  • [8] New region-of-interest image coding method
    Wang, Ruixin
    Wu, Jin
    Chen, Min
    Chen, Jingjing
    [J]. REMOTE SENSING AND GIS DATA PROCESSING AND APPLICATIONS; AND INNOVATIVE MULTISPECTRAL TECHNOLOGY AND APPLICATIONS, PTS 1 AND 2, 2007, 6790
  • [9] Preprocessing method for region-of-interest video call compression
    Heo, Seon
    Koo, Hyung Il
    Cho, Nam Ik
    [J]. 2014 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA), 2014,
  • [10] A new method in locating and segmenting palmprint into region-of-interest
    Poon, C
    Wong, DCM
    Shen, HC
    [J]. PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 4, 2004, : 533 - 536