TECHNICAL ASPECTS IN STUDYING PERITONEAL MORPHOLOGY IN ANIMAL MODELS OF PERITONEAL DIALYSIS

被引:0
|
作者
Duman, Soner [1 ]
Sen, Sait [2 ]
机构
[1] Ege Univ, Sch Med, Dept Nephrol, Izmir, Turkey
[2] Ege Univ, Sch Med, Dept Pathol, Izmir, Turkey
来源
关键词
Peritoneal histology; experimental studies; fixatives; standardization; VASCULATURE; PREVENT;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: Peritoneal biopsies are considered useful for gaining a better understanding of the pathophysiology of the peritoneum during experimental peritoneal dialysis (PD). Different peritoneal tissue samples (i.e., abdominal wall, liver, diaphragm, intestine, and omentum) may be used, but there can be artifacts due to peritoneal tissue processing. Aim: To investigate differences in peritoneal membranes from different parts of the peritoneum, and also 2 different fixatives, in experimental PD and a peritonitis model in rats. Methods: Peritoneal tissues from the anterior abdominal wall, liver, omentum, and intestine were taken from each of 3 groups of animals: sham, experimental PD, and peritonitis model. Tissue samples were immediately fixed with 4% formaldehyde and routinely processed for histological examination. Two parietal peritoneal tissue samples according to longitudinal and horizontal sections of anterior wall inner abdominal muscle were also taken. All samples were immediately fixed with 4% formaldehyde and B5 fixative (B5), and then routinely processed for histological examination. Results: In all groups, histopathological findings were more commonly seen in the abdominal wall samples. There were no changes observed in peritoneal membranes other than those of anterior abdominal wall samples from both sham and PD model rats. However, there was a significant difference between anterior and posterior facets of liver in the peritonitis model. Furthermore, the antimesenteric site of intestinal peritoneum was less affected than the mesenteric site. There were no significant histopathological differences between B5 and 4% formaldehyde fixation (p > 0.05). Conclusion: Our results suggest that peritoneum obtained from the anterior abdominal wall is the most affected area and therefore the most suitable site to investigate peritoneal changes in the experimental rat PD model. There were no significant differences between fixation with 4% formaldehyde and B5 solution. Abdominal wall samples should be of the same direction of inner abdominal muscle, that is, horizontal sectioning should be used for measurements of the submesothelial area.
引用
收藏
页码:S40 / S44
页数:5
相关论文
共 50 条
  • [1] Animal models for peritoneal dialysis
    Wieczorowska-Tobis, K
    Breborowicz, A
    Pawlaczyk, K
    Kuzlan-Pawlaczyk, M
    Polubinska, A
    Oreopoulos, DG
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 1999, 19 : S189 - S192
  • [2] Animal models in peritoneal dialysis
    Nikitidou, Olga
    Peppa, Vasiliki I.
    Leivaditis, Konstantinos
    Eleftheriadis, Theodoros
    Zarogiannis, Sotirios G.
    Liakopoulos, Vassilios
    [J]. FRONTIERS IN PHYSIOLOGY, 2015, 6
  • [3] Animal models in peritoneal dialysis
    Stojimirovic, B.
    Trbojevic-Stankovic, J.
    Nesic, D.
    [J]. SCANDINAVIAN JOURNAL OF LABORATORY ANIMAL SCIENCE, 2007, 34 (04) : 283 - 289
  • [4] Animal models of peritoneal dialysis - Discussion
    Topley, N
    Lameire, N
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (03) : 683 - 685
  • [5] Animal models of peritoneal dialysis: relevance, difficulties, and future
    Gonzalez-Mateo, G. T.
    Loureiro-Alvarez, J.
    Rayego-Mateos, S. .
    Ruiz-Ortega, M.
    Lopez-Cabrera, M.
    Selgas, R.
    Aroeira, L. S.
    [J]. NEFROLOGIA, 2008, 28 : 17 - 22
  • [6] Animal models in peritoneal dialysis: A story of kangaroos and ostriches
    Van Biesen, Wim
    Vanholder, Raymond
    Lameire, Norbert
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2006, 26 (05): : 571 - 573
  • [7] Animal models in peritoneal dialysis research: A need for consensus
    Mortier, S
    Lameire, NH
    De Vriese, AS
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2005, 25 (01): : 16 - 24
  • [8] Automated cyclers used in peritoneal dialysis: technical aspects for the clinician
    Chaudhry, Rafia I.
    Golper, Thomas A.
    [J]. MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2015, 8 (95-102): : 95 - 102
  • [9] PERITONEAL MORPHOLOGY AT THE INITIATION OF CHRONIC PERITONEAL DIALYSIS AND DIABETES
    Branco, Patricia
    Martins, Ana
    Carvalho, Tiago
    Ramos, Sancia
    Gaspar, Augusta
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33