A high performance board for acquisition of 64-channel ultrasound RF data

被引:14
|
作者
Boni, E. [1 ]
Cellai, A. [1 ]
Ramalli, A. [1 ]
Tortoli, P. [1 ]
机构
[1] Univ Florence, Elect & Telecommun Dept, I-50121 Florence, Italy
关键词
Open Ultrasound platform; Ultrasound research systems; Raw data acquisition; ULA-OP; MEDICAL ULTRASOUND; SYSTEM;
D O I
10.1109/ULTSYM.2012.0517
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The experimental test of new advanced ultrasound techniques frequently requires the acquisition of raw radiofrequency (RF) data from the individual elements of an array probe. The throughput rate and the total amount of these "pre-beamforming" data can be so high that only the most advanced research platforms are equipped to perform such acquisition, but may have difficulties to extend it over suitably long time intervals. In this paper, we report on the development of a high capacity (up to 36 GB) memory board which can be installed inside the Ultrasound Advanced Open Platform (ULA-OP). 64 channel raw RF data can be acquired without interfering with the programmed real-time operation modalities of the system. Examples of application are discussed.
引用
收藏
页码:2067 / 2070
页数:4
相关论文
共 50 条
  • [1] Communication Protocol on 64-Channel ECVT Data Acquisition System
    Yusuf, Arbai
    Tamsir, Agus Santoso
    Sudiana, Dodi
    Bastian, Andrew
    Melinda, Melinda
    Sudibyo, Harry S.
    [J]. 2018 5TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, COMPUTER, AND ELECTRICAL ENGINEERING (ICITACEE), 2018, : 11 - 14
  • [2] 64-channel ultrasound transducer amplifier
    Morizio, J
    Guhados, S
    Castellucci, J
    von Ramm, O
    [J]. 2003 SOUTHWEST SYMPOSIUM ON MIXED-SIGNAL DESIGN, 2003, : 228 - 232
  • [3] A 64-Channel Data Acquisition System for Heterodyne Interferometric Plasma Density Diagnostics
    V. F. Gurko
    P. V. Zubarev
    A. N. Kvashnin
    A. D. Khil'chenko
    [J]. Instruments and Experimental Techniques, 2003, 46 : 619 - 623
  • [4] A 64-channel data acquisition system for heterodyne interferometric plasma density diagnostics
    Gurko, VF
    Zubarev, PV
    Kvashnin, AN
    Khil'chenko, AD
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2003, 46 (05) : 619 - 623
  • [5] Design of 64-channel high-speed synchronization acquisition system for vibration
    Li Jin-chuan
    Chen Guo-ping
    Zou Yuan-wen
    Huang Xue-jin
    [J]. ROCK AND SOIL MECHANICS, 2009, 30 : 304 - 308
  • [6] 64-channel fiber-optic ultrasound detector array with high sensitivity for photoacoustic imaging
    Wang, Anqi
    Yang, Liuyang
    Xu, Dongchen
    Chen, Geng
    Dai, Chenhao
    Sun, Qizhen
    [J]. 2023 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXHIBITION, OFC, 2023,
  • [7] A 64-Channel Data Acquisition System-Based Ultralow Noise Transimpedance Amplifier for an Ionization Profile Monitor
    Wang, Tian
    Li, Zhixue
    Xie, Hongming
    Wu, Junxia
    Gu, Kewei
    Wei, Yuan
    Su, Jianjun
    Tian, Ruixia
    Wang, Yanyu
    Pan, Jin
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (08) : 1913 - 1922
  • [8] Real-time monitoring system of RF near-field distribution images on the basis of 64-channel parallel electro-optic data acquisition
    Sasagawa, Kiyotaka
    Tsuchiya, Masahiro
    [J]. IEICE ELECTRONICS EXPRESS, 2005, 2 (24): : 600 - 606
  • [9] 64-channel array coil for single echo acquisition magnetic resonance imaging
    McDougall, MP
    Wright, SM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 386 - 392
  • [10] UltraLight: An Ultrafast Imaging Platform based on a Digital 64-Channel Ultrasound Probe
    Hager, Pascal Alexander
    Speicher, Daniel
    Degel, Christian
    Benini, Luca
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,