Comparison of two types of acoustic biosensors to detect immunoreactions: Love-wave sensor working in dynamic mode and QCM working in static mode

被引:16
|
作者
Matatagui, D. [1 ]
Fontecha, J. [1 ]
Fernandez, M. J. [1 ]
Oliver, M. J. [2 ]
Hernando-Garcia, J. [2 ]
Sanchez-Rojas, J. L. [2 ]
Gracia, I. [3 ]
Cane, C. [3 ]
Santos, J. P. [1 ]
Horrillo, M. C. [1 ]
机构
[1] ISI CSIC, GRIDSEN, Madrid 28006, Spain
[2] Univ Castilla La Mancha, ETSI Ind, Area Tecnol Elect, E-13071 Ciudad Real, Spain
[3] CSIC, Inst Microelect Barcelona, Bellaterra 08193, Spain
来源
关键词
Love wave; Microfluidic; QCM; Immunodetection; Biosensor; Antibody conjugated; SENSITIVITY; ARRAY;
D O I
10.1016/j.snb.2013.02.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Love-wave device and a PDMS microfluidic chip have been developed in order to measure immunoreactions in liquid media, operating in dynamic mode (continuous flow-through). The obtained results with the above system for the detection of rabbit immunoglobulin by means of an antibody of goat anti-rabbit have been compared with those obtained by the most used acoustic wave device, the quartz crystal microbalance (QCM), which has worked in static mode. It has been demonstrated once again that QCM is an excellent tool as an immunosensor, although the Love-wave device is a good alternative due to its higher sensitivity. The dynamic mode improves the response time and the limit of detection. In addition, the use of microchannels has allowed working with a small sample volume for a long period of time in dynamic mode. On the other hand, a secondary antibody conjugated with gold nanoparticles has been used as a different method to measure the desired concentrations of antigens, obtaining in this case, a greater frequency shift. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 3 条
  • [1] Comparative evaluation between two acoustic immunosensors: Love-wave and QCM, and systems of measurement: dynamic and static
    Matatagui, D.
    Fontecha, J.
    Fernandez, M. J.
    Oliver, M. J.
    Hernando-Garcia, J.
    Sanchez-Rojas, J. L.
    Gracia, I.
    Cane, C.
    Santos, J. P.
    Horrillo, M. C.
    26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 174 - 177
  • [2] Microfluidics applied to Love-wave devices to detect biological warfare agents in dynamic mode
    Matatagui, D.
    Fontecha, J.
    Fernandez, M. J.
    Santos, J. P.
    Horrillo, M. C.
    Gracia, I.
    Cane, C.
    PROCEEDINGS OF THE 2013 SPANISH CONFERENCE ON ELECTRON DEVICES (CDE 2013), 2013, : 115 - 118
  • [3] Comparison of Acoustic Wave Sensors With Different Cut LiNbO3 Working on Pseudo-LFE Mode
    Zhang, Zhitian
    Zhang, Chao
    Ma, Tingfeng
    Wang, Wenyan
    Chen, Jin
    Liu, Yan
    IEEE SENSORS JOURNAL, 2013, 13 (06) : 2109 - 2114