Comparison of flat-panel radiography and computed radiography in urography

被引:5
|
作者
Zähringer, M
Kamm, KF
Krug, B
Braun, W
Coburger, S
Winnekendonk, G
Krüger, K
Haupt, G
Lackner, K
机构
[1] Univ Cologne, Inst & Poliklin Radiol Diagnost, D-50924 Cologne, Germany
[2] Philips Med Syst, Hamburg, Germany
[3] Univ Cologne, Inst Med Stat Informat & Epidemiol, Cologne, Germany
[4] Univ Cologne, Klin & Poliklin Urol, Cologne, Germany
关键词
digial radiography; digital flat-panel radiography; computed radiography; uroradiology;
D O I
10.1055/s-2002-28266
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the diagnostic value of digital flat-panel radiography in uroradiology the i.v. urograms of patients who had been examined with computed radiography and digital flat-panel radiography were compared regarding image quality. Methods: 50 patients who underwent clinically indicated Lv. urography were examined with digital flat-panel radiography and computed radiography. In order to avoid unnecessary double exposure to X-rays, patients were examined either by flat-panel or computed radiography before injection of contrast media. Each further clinically indicated exposure after administration of contrast media was done by alternating the other examination technique. The digital images were compared by 4 radiologists regarding image quality for the detection of defined anatomic structures. Results: Digital flat-panel radiography showed an image quality of the liver, spleen and both kidneys that was similar to computed radiography. The urinary tract, lumbar spine, pelvis and psoas muscle were significantly better visible on flat-panel radiography images. Conclusions: Compared to computed radiography there is no loss of image information by using digital flat-panel radiography in uroradiology. On the contrary, some anatomic structures on abdominal survey images show better image quality. In conclusion, digital flat-panel radiography has the potential to replace computed radiography in uroradiologic examinations.
引用
收藏
页码:625 / 630
页数:6
相关论文
共 50 条
  • [1] Pneumothorax detection: Comparison of flat-panel amorphous silicon and computed radiography detectors
    Kampschulte, A
    Hansmann, J
    Hahmann, M
    Leutloff, UC
    Fink, C
    Kauffmann, GW
    [J]. RADIOLOGY, 2000, 217 : 124 - 124
  • [2] A flat-panel detector digital radiography and a storage phosphor computed radiography: Screening for pneumoconioses
    Takashima, Yoshihiro
    Suganuma, Narufumi
    Sakurazawa, Hirofumi
    Itoh, Harumi
    Hirano, Harukazu
    Shida, Hisao
    Kusaka, Yukinori
    [J]. JOURNAL OF OCCUPATIONAL HEALTH, 2007, 49 (01) : 39 - 45
  • [3] Objective Comparison of Digital Flat-panel Radiography Detectors
    Ostojic, Vladimir
    Starcevic, Djordje
    Petrovic, Vladimir
    [J]. 2016 INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (INDEL), 2016,
  • [4] Clinical comparison of imaging performance of a digital radiography system with a new flat-panel detector vs computed radiography
    Mildenberger, P
    Vogel, N
    Herber, SS
    Kaemmerer, M
    Thelen, M
    [J]. RADIOLOGY, 2000, 217 : 518 - 518
  • [5] Flat-panel DR detectors for radiography and fluoroscopy
    Yorkston, John
    [J]. SPECIFICATIONS PERFORMANCE EVALUATION AND QUALITY ASSURANCE OF RADIOGRAPHIC AND FLUOROSCOPIC SYSTEMS IN THE DIGITAL ERA, 2006, (30): : 177 - 228
  • [6] Improved contrast-detail detection with flat-panel digital radiography: Comparison with computed radiography and a conventional film-screen system
    Erb, G
    Aretz, K
    Hahmann, M
    Radeleff, BA
    Hansmann, J
    Kauffmann, GW
    [J]. RADIOLOGY, 2000, 217 : 164 - 164
  • [7] Reducing the radiation dose during excretory urography:: Flat-panel silicon X-ray detector versus computed radiography
    Zähringer, M
    Hesselmann, V
    Schulte, O
    Kamm, KF
    Braun, W
    Haupt, G
    Krug, B
    Lackner, K
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (04) : 931 - 937
  • [8] Digital radiography with flat-panel detectors: the missing link
    Strotzer, M
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (07) : 1603 - 1604
  • [9] Digital radiography with flat-panel detectors: the missing link
    Michael Strotzer
    [J]. European Radiology, 2002, 12 : 1603 - 1604
  • [10] Comparing image quality of flat-panel chest radiography with storage phosphor radiography and film-screen radiography
    Ganten, M
    Radeleff, B
    Kampschulte, A
    Daniels, MD
    Kauffmann, GW
    Hansmann, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) : 171 - 176