Impedance Spectroscopy of Aqueous Solution Samples of Different Glucose Concentrations for the Exploration of Non-Invasive-Continuous-Blood-Glucose-Monitoring

被引:5
|
作者
Satish [1 ,2 ]
Sen, K. [3 ]
Anand, S. [1 ]
机构
[1] Indian Inst Technol, Ctr Biomed Engn, New Delhi, India
[2] CSIR Natl Phys Lab, LF HF Impedance & DC Metrol, New Delhi, India
[3] Indian Inst Technol, Dept Text Engn, New Delhi, India
来源
关键词
Non-invasive; Diabetes; Glucose concentration; Electrical impedance; Capacitance; Conductance;
D O I
10.1007/s12647-017-0242-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Continuous blood-glucose-monitoring provides maximal information about the fluctuations of blood-glucose levels throughout the day and thus plays a vital role in controlling the blood-glucose level in diabetes. The conventional methods of testing blood-glucose level are invasive, painful and are unsuitable for continuous monitoring. Thus, the battle for developing bloodless and painless blood-glucose monitors has begun from past three decades. Electrical bio-impedance spectroscopy has been suggested as one of the potential technique for the development of such monitors. The present work is aimed at impedance spectroscopy to demonstrate the variation in electrical bio-impedance properties of blood with the change in glucose concentration. Glucose-dependent electrical impedance parameters of aqueous solution samples, of increasing glucose concentration have been determined to accomplish the same. The glucose-dependent capacitance and conductance illustrates the direct variations in impedance parameters with respect to change in glucose concentration. Measurement automation program is developed to ease the measurement procedure, to support continuous measurement, and to compute short-term repeatability of measurement results. The experimental results of the present work will be used to implement electrical bio-impedance spectroscopy technique in the development of non-invasive-continuous-blood-glucose monitoring system.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 50 条
  • [1] Impedance Spectroscopy of Aqueous Solution Samples of Different Glucose Concentrations for the Exploration of Non-Invasive-Continuous-Blood-Glucose-Monitoring
    Kushal Satish
    Sneh Sen
    [J]. MAPAN, 2018, 33 : 185 - 190
  • [2] Review of non-invasive continuous glucose monitoring based on impedance spectroscopy
    Huang, Jiamei
    Zhang, Ying
    Wu, Jayne
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2020, 311
  • [3] Non-invasive glucose monitoring using impedance spectroscopy
    Narasimham, Shruti
    Kaila, Gaurav
    Anand, Sneh
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2014, 14 (03) : 225 - 232
  • [4] Non-invasive impedance based continuous glucose monitoring system
    Talary, M. S.
    Dewarrat, F.
    Huber, D.
    Falco-Jonasson, L.
    Caduff, A.
    [J]. 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 636 - +
  • [5] Multi-modality analysis of glucose aqueous solution using photoacoustic and dielectric spectroscopy for non- invasive glucose monitoring
    Tajima, Takuro
    Tanaka, Yujiro
    Nakamura, Masahito
    Seyama, Michiko
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [6] Non invasive glucose monitoring using a multisensor concept based on impedance spectroscopy
    Caduff, Andreas
    Talary, Mark
    Donath, Marc
    Klisic, Jelena
    [J]. DIABETES, 2007, 56 : A106 - A106
  • [7] Non-invasive, continuous glucose monitoring system based on impedance spectroscopy: A proof of concept study.
    Caduff, A
    Kapitza, C
    Dewarrat, R
    Hirt, E
    Heinemann, L
    [J]. DIABETOLOGIA, 2002, 45 : A279 - A279
  • [8] Non-invasive monitoring of blood glucose using Raman spectroscopy
    Peterson, CM
    Peterson, KP
    Chaiken, J
    Finney, W
    Knudson, PE
    Weinstock, RS
    [J]. DIABETES, 2000, 49 : A121 - A121
  • [9] Differential photoacoustic spectroscopy with continuous-wave lasers for non-invasive blood glucose monitoring
    Tanaka, Y.
    Tajima, T.
    Seyama, M.
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
  • [10] Differential Continuous Wave Photoacoustic Spectroscopy for Non-Invasive Glucose Monitoring
    Tanaka, Yujiro
    Tajima, Takuro
    Seyama, Michiko
    Waki, Kayo
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (08) : 4453 - 4458