A comparison of wavefront aberrations in eyes wearing different types of soft contact lenses

被引:23
|
作者
Jiang, Hongjun
Wang, Dan
Yang, Lina
Xie, Peiying
He, Ji C.
机构
[1] Peking Univ, Optometry & Ophthalmol Ctr, Beijing 100083, Peoples R China
[2] New England Coll Optometry, Boston, MA USA
关键词
soft contact lens; manufacturing methods; wavefront aberration; Zernike aberration;
D O I
10.1097/01.opx.0000236786.96023.9c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this study is to investigate the optical quality of eyes wearing different types of soft contact lenses (sCLs) using wavefront aberrometry. Method. A psychophysical aberrometer (WFA1000B; BriteEye, SuZhou, China) was used to measure wavefront aberrations for 56 eyes of 28 subjects under four conditions: 1) without contact lenses (non-CL), 2) with lathe-cut contact lenses (lathe-cut CL; Shuliang, Weicon Optics, Shanghai, China), 3) with cast-molded contact lenses (cast-molded CL; Vistavue, J&J Vision Care, U.S.), and 4) with spun-cast contact lenses (spun-cast CL; Lanfenzhiji, Justcome Optics, Beijing, China). The three types of sCLs were made from different materials and lens design. The root mean square (RMS) values of the wavefront aberrations and individual Zernike aberrations were calculated and compared among the CL-wearing conditions. Results. Astigmatism was not significantly changed by any of the three soft contact lenses when compared with the non-CL condition. However, a significant difference in the RMS values of higher-order aberrations was observed between the lens types (F = 8.29, p < 0.0001). Induced higher-order aberrations were found for both the cast-molded CL and the spun-cast CL conditions. There were significant differences in the aberrations in each of the higher orders between the CL conditions (F = 3.77, p = 0.011 for third order; F = 5.31, p = 0.002 for fourth order; F = 13.86, p < 0.0001 for fifth and higher orders). More higher-order Zernike aberrations such as coma and spherical aberration were induced by cast-molded CLs and/or the spun-cast CLs. Conclusion. Wavefront aberrations in the eyes with soft contact lenses vary from one individual lens type to another. Although the variation in wavefront aberrations could be attributed to the differences in the methods of manufacture, influences from other factors such as the lens material and lens design could not be excluded and deserve further investigation.
引用
收藏
页码:769 / 774
页数:6
相关论文
共 50 条
  • [1] Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses
    Bellucci, R
    Morselli, S
    Piers, P
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (04) : 297 - 306
  • [2] Evaluating accommodative response of eyes wearing soft contact lenses for myopia control
    Cheng, Xu
    Kollbaum, Pete S.
    Sah, Raman Prasad
    Meyer, Dawn
    Almaghshi, Mona
    Xu, Jing
    Brennan, Noel A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [3] Wavefront aberrations in eyes with acrysof monofocal intraocular lenses
    Padmanabhan, P
    Yoon, G
    Porter, J
    Rao, SK
    Roy, J
    Choudhury, M
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (03) : 237 - 242
  • [4] Comparison of aberrations in different types of progressive power lenses
    Villegas, EA
    Artal, P
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2004, 24 (05) : 419 - 426
  • [5] Higher-Order Aberrations When Wearing Sphere and Toric Soft Contact Lenses
    Berntsen, David A.
    Merchea, Mohinder M.
    Richdale, Kathryn
    Mack, Carla J.
    Barr, Joseph T.
    [J]. OPTOMETRY AND VISION SCIENCE, 2009, 86 (02) : 115 - 122
  • [6] Effect of soft and rigid gas-permeable contact lenses and aging on wavefront aberrations
    Hirohara, Y
    Mihashi, T
    Suzaki, A
    Ninomiya, S
    Kuroda, T
    Maeda, N
    Fujikado, T
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U303 - U303
  • [7] Comparison of the wavefront aberrations for two different types of cataract surgeries
    Ma, L
    Zhang, J
    Liu, C
    He, J
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U76 - U76
  • [8] Monochromatic wavefront aberrations in the human eye with contact lenses
    Lu, F
    Mao, XJ
    Qu, J
    Xu, D
    He, JC
    [J]. OPTOMETRY AND VISION SCIENCE, 2003, 80 (02) : 135 - 141
  • [9] Optical performance of different soft contact lenses based on wavefront analysis
    Fagnani Gatti, Roberta
    Lipener, Cesar
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2008, 71 (06) : 42 - 46
  • [10] Comparison of wavefront aberrations in rabbit and human eyes
    Chen, Li
    Huang, Ling C.
    Gray, Brad
    Chernyak, Dimitri A.
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2014, 97 (06) : 534 - 539