Nonintrusive disaggregation of residential air-conditioning loads from sub-hourly smart meter data

被引:53
|
作者
Perez, Krystian X. [1 ,3 ]
Cole, Wesley J. [1 ,3 ]
Rhodes, Joshua D. [2 ,3 ]
Ondeck, Abigail [1 ,3 ]
Webber, Michael [2 ,3 ,4 ]
Baldea, Michael [1 ,3 ,5 ]
Edgar, Thomas F. [1 ,3 ,4 ]
机构
[1] Univ Texas Austin, McKetta Dept Chem Engn, Austin, TX 78712 USA
[2] Univ Texas Austin, Dept Civil Architectural & Environm Engn, Austin, TX 78712 USA
[3] Univ Texas Austin, Dept Mech Engn, Austin, TX 78712 USA
[4] Univ Texas Austin, Energy Inst, Austin, TX 78712 USA
[5] Univ Texas Austin, Inst Computat Engn & Sci, Austin, TX 78712 USA
基金
美国国家科学基金会; 美国能源部;
关键词
Nonintrusive load monitoring; Disaggregation; Residential energy; Air conditioning; Smart meter; CONSUMPTION;
D O I
10.1016/j.enbuild.2014.06.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The installation of smart meters has provided an opportunity to better analyze residential energy consumption and energy-related behaviors. Air-conditioning (A/C) use can be determined through non-intrusive load monitoring, which separates A/C cooling energy consumption from whole-house energy data. In this paper, a disaggregation technique is described and executed on 1-mM smart meter data from 88 houses in Austin, TX, USA, from July 2012 through June 2013. Nineteen houses were sub-metered to validate the accuracy of the disaggregation technique. The R-2 value between the predicted and actual A/C energy use for the 19 houses was 0.90. The algorithm was then applied to all houses. On average, daily energy use from A/C increased by 25 +/- 11 kWh between a mild temperature day of 15.5 degrees C (60 degrees F) and a hotter day of 31.5 degrees C (89 degrees F), with an 11 kWh increase just during peak hours (14:00-20:00). Average time operated, number of cycles, and A/C fraction of energy were found to increase linearly with outdoor temperature up to 25 degrees C (77 degrees F); a plateau was detected at higher temperatures. The accuracy of A/C disaggregation on 5-min data was found to be comparable to 1-min data. However, 15-min data did not yield accurate results due to insufficient granularity. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:316 / 325
页数:10
相关论文
共 50 条
  • [1] Machine learning based disaggregation of air-conditioning loads using smart meter data
    Najafi, Behzad
    Di Narzo, Luca
    Rinaldi, Fabio
    Arghandeh, Reza
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (21) : 4755 - 4762
  • [2] Estimating air conditioning energy consumption of residential buildings using hourly smart meter data
    Jin, Xu
    Wang, Shunjiang
    Hu, Qinran
    Zhang, Yuanshi
    Qiu, Peng
    Liu, Yu
    Dou, Xiaobo
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [3] Disaggregation of Cold Appliance Loads from Smart Meter Data Processing
    Zufferey, Thierry
    Hug, Gabriela
    Valverde, Gustavo
    [J]. 2020 IEEE PES TRANSMISSION & DISTRIBUTION CONFERENCE AND EXHIBITION - LATIN AMERICA (T&D LA), 2020,
  • [4] Smart meter data-driven evaluation of operational demand response potential of residential air conditioning loads
    Qi, Ning
    Cheng, Lin
    Xu, Helin
    Wu, Kuihua
    Li, XuLiang
    Wang, Yanshuo
    Liu, Rui
    [J]. APPLIED ENERGY, 2020, 279
  • [5] The use of sub-hourly primary meter data to identify electricity savings in municipal buildings
    Ferreira, Vasco
    Fleming, Paul
    [J]. ENERGY EFFICIENCY, 2014, 7 (05) : 879 - 889
  • [6] A NEW METHOD FOR DETERMINING SUB-HOURLY SOLAR RADIATION FROM HOURLY DATA
    McDowell, Timothy P.
    Letellier-Duchesne, Samuel
    Kummert, Michael
    [J]. 2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 518 - 525
  • [7] The use of sub-hourly primary meter data to identify electricity savings in municipal buildings
    Vasco Ferreira
    Paul Fleming
    [J]. Energy Efficiency, 2014, 7 : 879 - 889
  • [8] Proportional Identification of Residential Air-Conditioning Loads Based on Graph Theory
    Li, Dairui
    Li, Zhiyi
    Xin, Huanhai
    [J]. 2021 IEEE IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA (IEEE I&CPS ASIA 2021), 2021, : 1624 - 1629
  • [9] A new method utilizing smart meter data for identifying the existence of air conditioning in residential homes
    Chen, Mo
    Sanders, Kelly T.
    Ban-Weiss, GeorgeA
    [J]. ENVIRONMENTAL RESEARCH LETTERS, 2019, 14 (09):
  • [10] Intelligent Residential Air-Conditioning System With Smart-Grid Functionality
    Thomas, Auswin George
    Jahangiri, Pedram
    Wu, Di
    Cai, Chengrui
    Zhao, Huan
    Aliprantis, Dionysios C.
    Tesfatsion, Leigh
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (04) : 2240 - 2251