Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: Comparison to IVUS

被引:184
|
作者
Pohle, Karsten
Achenbach, Stephan
MacNeill, Briain
Ropers, Dieter
Ferencik, Maros
Moselewski, Fabian
Hoffmann, Udo
Brady, Thomas J.
Jang, Ik-Kyung
Daniel, Werner G.
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med, Erlangen, Germany
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
关键词
imaging; computed tomography; plaque; atherosclerosis;
D O I
10.1016/j.atherosclerosis.2006.01.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Multi-detector row Computed Tomography (MDCT) permits non-invasive visualization of the coronary arteries. The ability to visualize and, with limitations, to characterize non-calcified coronary atherosclerotic plaque has been described. We investigated the CT attenuation of non-calcified plaques as determined by 16-slice MDCT in comparison to intravascular ultrasound (IVUS). Methods and results: Thirty-two patients were investigated by contrast-enhanced 16-slice CT. In addition, IVUS of one coronary artery (motorized pullback) was performed (LM+LAD: 22, LM+LCX: 4, RCA: 6). At 252 sites within the coronary system, in which non-calcified atherosclerotic plaque could be identified both in MDCT and IVUS, the CT attenuation within the plaque was measured using a centrally placed region of interest and correlated to the appearance of the plaque in IVUS at the corresponding location. The mean CT attenuation within plaque that corresponded to hyper-echogenic appearance in IVUS was 121 +/- 34 HU (n = 76). The mean CT attenuation within plaque that corresponded to hypo-echogenic appearance was 58 +/- 43 HU (n = 176, p < 0.001). However, there was substantial overlap of the density values measured by MDCT in the two groups. Conclusions: A significant difference of the mean CT attenuation within atherosclerotic lesions of hypo-echogenic and hyper-echogenic appearance in IVUS could be observed. However, we observed substantial overlap of attenuation values between plaque types so that the differentiation of "vulnerable" and "stable" plaques based on their CT attenuation is doubtful. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 50 条
  • [1] Characterization of noncalcified coronary atherosclerotic plaque by multicletector row CT: Comparison to IVUS
    Achenbach, S
    Ropers, D
    Pohle, K
    Hoffmann, U
    Ferencik, M
    Moselewski, F
    Chan, R
    Brady, TJ
    Jang, IK
    Daniel, WG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 295A - 295A
  • [2] Measurement of Coronary Atherosclerotic Plaque Volumes by Contrast-Enhanced Multi-detector CT: Correlation to IVUS
    Achenbach, Stephan
    Seltmann, Martin
    Marwan, Mohamed
    Pflederer, Tobias
    Schepis, Tiziano
    Ropers, Dieter
    Daniel, Werner G.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A272 - A272
  • [3] Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT
    Christoph R. Becker
    Konstantin Nikolaou
    Michael Muders
    Gregor Babaryka
    Alexander Crispin
    U. Joseph Schoepf
    Udo Loehrs
    Maximilian F. Reiser
    [J]. European Radiology, 2003, 13 : 2094 - 2098
  • [4] Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT
    Becker, CR
    Nikolaou, K
    Muders, M
    Babaryka, G
    Crispin, A
    Schoepf, UJ
    Loehrs, U
    Reiser, MF
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (09) : 2094 - 2098
  • [5] Non-Calcified Coronary Atherosclerotic Plaque Characterization by Dual Energy Computed Tomography
    Yamak, Didem
    Panse, Prasad
    Pavlicek, William
    Boltz, Thomas
    Akay, Metin
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (03) : 939 - 945
  • [6] Measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multi-detector CT: Comparison to IVUS
    Achenbach, S
    Ropers, D
    Hoffmann, U
    Pohle, K
    MacNeill, B
    Ferencik, M
    Chan, R
    Pomerantsev, E
    Schmid, M
    Brady, TJ
    [J]. CIRCULATION, 2003, 108 (17) : 529 - 529
  • [7] Influence of age and cardiovascular risk factors on the presence of calcified and non-calcified coronary atherosclerotic plaque detected by coronary CT angiography
    Geckeis, K.
    Achenbach, S.
    Ropers, D.
    Renz, A.
    Daniel, W. G.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 618 - 618
  • [8] Correction of lumen contrast-enhancement influence on non-calcified coronary atherosclerotic plaque quantification on CT
    Kristanto, Wisnumurti
    Tuncay, Volkan
    Vliegenthart, Rozemarijn
    van Ooijen, Peter M. A.
    Oudkerk, Matthijs
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (02): : 429 - 436
  • [9] Correction of lumen contrast-enhancement influence on non-calcified coronary atherosclerotic plaque quantification on CT
    Wisnumurti Kristanto
    Volkan Tuncay
    Rozemarijn Vliegenthart
    Peter M. A. van Ooijen
    Matthijs Oudkerk
    [J]. The International Journal of Cardiovascular Imaging, 2015, 31 : 429 - 436
  • [10] Noninvasive detection of calcified and non-calcified coronary plaques by Multidetector-row CT: A comparison with intracoronary ultrasound
    Kopp, AF
    Schroeder, S
    Kuettner, A
    Ohnesorge, BM
    Georg, C
    Claussen, CD
    [J]. RADIOLOGY, 2000, 217 : 234 - 234